{"product_id":"serpentin-devaporateur-comfortmaker-eaa5x30m17a-a-2-5-tonnes","title":"COMFORTMAKER EAA5X30M17A Evaporator A-Coil | 2.5 Tons","description":"\u003ch2\u003eA two-storey home, a 16-7\/16 in furnace: the 2.5-ton Comfortmaker EAA5X30M17A\u003c\/h2\u003e\n\u003cp\u003ePicture a suburban two-storey home, on the South Shore or in Laval. Furnace in the basement, ducts running up to the second floor, an old central air conditioner that has seen better days or, worse, three window units buzzing in July. The owner wants a single, quiet system that cools and heats. The \u003cstrong\u003eComfortmaker EAA5X30M17A coil\u003c\/strong\u003e is one of the parts that make this possible.\u003c\/p\u003e\n\u003cp\u003eIt is a 2.5-ton (30,000 BTU\/h) evaporator coil, uncased, running on R-454B refrigerant, with a width of 16-7\/16 in. AirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhat an installation day looks like\u003c\/h3\u003e\n\u003cp\u003eWe arrive early in the day with the coil, the outdoor unit and the piping. Step one: measure the furnace and read the nameplate, check the blower and take a look at the electrical panel. The last two checks matter as much as the coil itself, because they decide the rest of the job.\u003c\/p\u003e\n\u003cp\u003eNext, the coil takes its place in the plenum. If the width does not match exactly, we build an insulated sheet-metal transition. We seal the joints so the air really passes through the coil rather than around it. Outside, the outdoor unit is set on a pad or bracket; the piping is brazed, tested with nitrogen to confirm it is leak-tight, then put under vacuum.\u003c\/p\u003e\n\u003cp\u003eThe day ends with connecting the condensate drain and the thermostat, commissioning, adjusting the airflow and a walk-through at your home: what to adjust where, how to change the filter, what to watch for. Our refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01, and AirGreen is a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company in Montreal for more than fifteen years.\u003c\/p\u003e\n\n\u003ch3\u003eAn intermediate size, for a reason\u003c\/h3\u003e\n\u003cp\u003eThe 2.5-ton size suits a two-storey home with a well-insulated upper floor or a bungalow with a partly finished basement. It sits between the small and the large sizes of the series. Our role is to confirm it is the right one: a load calculation that looks at the glazing, the insulation and the number of rooms served. If it points to 2 tons or 3 tons, we change models without argument.\u003c\/p\u003e\n\n\u003ch3\u003eThe outdoor units that connect to it\u003c\/h3\u003e\n\u003cp\u003eFor this coil, Comfortmaker publishes two certified matches.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eQ5H9V24*K*AAA\u003c\/strong\u003e heat pump: AHRI number 217953812. Capacities of 22,200 BTU\/h cooling and 23,800 BTU\/h heating at 47 °F, SEER2 15.2, HSPF2 9.0.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eN5H9V24*K*AAA\u003c\/strong\u003e heat pump: AHRI number 217953805. Same capacities and ratings as the previous one.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese numbers are not those of the M14A, even with the same outdoor units: the AHRI number links a specific coil to a specific outdoor unit. By asking any contractor for this number, you can compare quotes on the same basis.\u003c\/p\u003e\n\n\u003ch3\u003eM17A or M14A: a question of width\u003c\/h3\u003e\n\u003cp\u003eThe two 2.5-ton coils look alike. Same range, same capacity, same outdoor units, same TXV metering device. The difference is the width: 13-1\/8 in for the EAA5X30M14A, 16-7\/16 in for this one. If your furnace is wide, the M17A avoids having to narrow the plenum. If it is narrow, the M14A will be the more natural fit. A tape measure settles the question.\u003c\/p\u003e\n\u003cp\u003eElsewhere in the series:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X24M17A\u003c\/strong\u003e: 2 tons, same width as this model.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X36M17A\u003c\/strong\u003e and \u003cstrong\u003eEAA5X37M17A\u003c\/strong\u003e: 3 tons, also the same width.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X42M21A\u003c\/strong\u003e, \u003cstrong\u003eEAA5X48M21A\u003c\/strong\u003e, \u003cstrong\u003eEAA5X61M21A\u003c\/strong\u003e and \u003cstrong\u003eEAA5X60M24A\u003c\/strong\u003e: larger widths, for bigger homes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat the coil really does\u003c\/h3\u003e\n\u003cp\u003eThe coil is a heat exchanger placed in the path of the air. In summer, the refrigerant evaporating in its tubes picks up heat from the home's air, and the moisture condenses before leaving through the drain. In winter, if the outdoor unit is a heat pump, the cycle reverses and the heat brought in from outside is delivered to the building's air by that same exchanger.\u003c\/p\u003e\n\u003cp\u003eThe A shape, two sloped faces that meet, offers a large surface in a tight space. The manufacturer allows only the vertical positions, upflow or downflow; horizontal is prohibited.\u003c\/p\u003e\n\n\u003ch3\u003eWhy an uncased coil\u003c\/h3\u003e\n\u003cp\u003eAn \"uncased\" coil has no metal casing around it. It slides into the furnace plenum, or into a cabinet built on site. For the homeowner, this means less height to find above the unit and an installation that respects the existing space. For us, it means sealing carefully: without a factory casing, it is the quality of the plenum and the joints that ensures all the air passes through the exchanger.\u003c\/p\u003e\n\u003cp\u003eIn a basement mechanical room, which is often narrow and crowded by the water heater, the panel and the ducts, this installation flexibility is valuable. We explain before the work what we plan to move, if anything.\u003c\/p\u003e\n\n\u003ch3\u003eThe furnace keeps its place\u003c\/h3\u003e\n\u003cp\u003eIn an \"add-on\" installation, you keep the blower, filters and ducts of the furnace. It becomes the backup heat: when the outdoor temperature falls below a threshold we program with you, it takes over. For the coldest nights, it is insurance.\u003c\/p\u003e\n\u003cp\u003eThe coil has no efficiency rating on its own. The SEER2 and HSPF2 ratings belong to the certified system, and it is these, along with the AHRI number, that count for incentives.\u003c\/p\u003e\n\n\u003ch3\u003eEAA5X30M17A technical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand and range: Comfortmaker EAA5X.\u003c\/li\u003e\n\u003cli\u003eCategory: uncased coil.\u003c\/li\u003e\n\u003cli\u003eNominal capacity: 2.5 tons (30,000 BTU\/h).\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-454B.\u003c\/li\u003e\n\u003cli\u003eSize W × H × D: 16-7\/16 × 19-7\/8 in.\u003c\/li\u003e\n\u003cli\u003eWater removal: 3\/4 in FPT primary and secondary connections.\u003c\/li\u003e\n\u003cli\u003eSafety: factory-mounted generation 2, 5 V refrigerant sensor, incompatible with generation 1 dissipation boards.\u003c\/li\u003e\n\u003cli\u003eWarranty: 10 years on parts if registered within 90 days of installation; 5 years without registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe manufacturer states, in manual IM-EAA5X-05, that the furnace must be compatible with generation 2 dissipation when the coil is installed uncased. The ENERGY STAR match for the \"EA*5X\" family (EAM5X and EAA5X) is published with the Q5H9V, N5H9V, SoftSound B5H0V, B5H3V, C5H0V heat pumps and the Mainline C5H8T, all on R-454B.\u003c\/p\u003e\n\n\u003ch3\u003eWhat to check before ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil and the outdoor unit share R-454B and are installed together.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply to the certified match, not to an improvised assembly.\u003c\/li\u003e\n\u003cli\u003eThe furnace width and its blower must be suitable, which we confirm at your home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eBrand and manufacturer\u003c\/h3\u003e\n\u003cp\u003eComfortmaker is a brand of International Comfort Products (ICP), a Carrier subsidiary. Its R-454B evaporator coils go with its central heat pumps and air conditioners, installed on a furnace or blower cabinet.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert incentive\u003c\/h3\u003e\n\u003cp\u003eThe matched Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation: we check it on the official list when we prepare your quote and put the application together with you.\u003c\/p\u003e\n\n\u003ch3\u003ePlan your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, look at the electrical service and give you a written quote for the complete system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e lets you spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402721685796,"sku":"EAA5X30M17A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EAA5X_EAA5X30M17A_00_2_5_TONNES_30000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765770","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-eaa5x30m17a-a-2-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}