{"product_id":"serpentin-devaporateur-comfortmaker-eaa5x37m17a-a-3-tonnes","title":"COMFORTMAKER EAA5X37M17A Evaporator A-Coil | 3 Tons","description":"\u003ch2\u003eEAA5X37M17A: reading the ratings of a 3-ton Comfortmaker coil\u003c\/h2\u003e\n\u003cp\u003eWhen two quotes for a central heat pump land on the table, they often look like lists of numbers that make no sense: SEER2, HSPF2, BTU\/h, AHRI number. The \u003cstrong\u003eComfortmaker EAA5X37M17A evaporator coil\u003c\/strong\u003e is a good example for learning to read them. It is a 3-ton (36,000 BTU\/h) model, uncased, running on R-454B refrigerant, 16-7\/16 in wide, whose published matches show, according to the sheet, SEER2 16.0, HSPF2 9.5.\u003c\/p\u003e\n\u003cp\u003eAirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eA coil without ratings, a system with ratings\u003c\/h3\u003e\n\u003cp\u003eFirst point to remember: the coil alone has no efficiency rating. Ratings belong to a system tested as a whole: this coil, a given outdoor unit, and the AHRI number that certifies the trio. Change one element and the numbers change. That is why we never promise a rating without naming the outdoor unit that goes with it.\u003c\/p\u003e\n\n\u003ch3\u003eThe two systems for the 37M17A\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eQ5H9V24*K*AAA\u003c\/strong\u003e heat pump, AHRI number 217953700: 22,800 BTU\/h cooling, 24,800 BTU\/h heating at 47 °F, SEER2 16.0, HSPF2 9.5.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eN5H9V24*K*AAA\u003c\/strong\u003e heat pump, AHRI number 217953693: same capacities and same ratings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eQuick reading: SEER2 measures cooling efficiency over a season, HSPF2 measures heating efficiency. The higher these numbers, the less the system uses for the same result. The 47 °F figure is the outdoor temperature at which the heating capacity is published; it says nothing about what happens at lower temperatures.\u003c\/p\u003e\n\n\u003ch3\u003eAnd the EAA5X36M17A, then?\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e36M17A\u003c\/strong\u003e is a coil of the same size: 3 tons, 16-7\/16 in wide, same outdoor units, same 16-7\/16 × 19-7\/8 in dimensions. What sets them apart on paper are the AHRI numbers and the published ratings of their matches. If the quote in your hands cites one or the other, make sure the model number and the AHRI number agree: a mix-up skews any comparison. We check them before ordering.\u003c\/p\u003e\n\u003cp\u003eThe other models in the series:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X24M17A\u003c\/strong\u003e and \u003cstrong\u003eEAA5X30M17A\u003c\/strong\u003e: same width, smaller capacities (2 tons and 2.5 tons).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X42M21A\u003c\/strong\u003e (3.5 tons), \u003cstrong\u003eEAA5X48M21A\u003c\/strong\u003e (4 tons): 19-15\/16 in wide.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X61M21A\u003c\/strong\u003e (5 tons, 19-15\/16 in) and \u003cstrong\u003eEAA5X60M24A\u003c\/strong\u003e (5 tons, 23-7\/16 in).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X24M14A\u003c\/strong\u003e and \u003cstrong\u003eEAA5X30M14A\u003c\/strong\u003e: 13-1\/8 in, for narrow furnaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShape, orientation and metering device\u003c\/h3\u003e\n\u003cp\u003eThis is an A-coil. Its two sloped faces form a roof over the condensate pan. Furnace air passes through it from bottom to top or from top to bottom, depending on whether the furnace is upflow or downflow: these are the only two positions the manufacturer allows. Horizontal installation is prohibited.\u003c\/p\u003e\n\u003cp\u003eThe metering device is a TXV. The drain, with its 3\/4 in FPT primary and secondary connections, carries away the water the coil produces in summer. We connect both, and we test the flow at commissioning.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComfortmaker, EAA5X range, uncased coil.\u003c\/li\u003e\n\u003cli\u003eNominal size of 3 tons (36,000 BTU\/h), R-454B refrigerant.\u003c\/li\u003e\n\u003cli\u003eDimensions W × H × D of 16-7\/16 × 19-7\/8 in.\u003c\/li\u003e\n\u003cli\u003eGeneration 2, 5 V refrigerant sensor, factory-installed, not compatible with generation 1 dissipation boards.\u003c\/li\u003e\n\u003cli\u003e10-year limited parts warranty with registration within 90 days of installation; 5 years without registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eManual IM-EAA5X-05 states that an uncased coil requires a furnace compatible with generation 2 dissipation. For ENERGY STAR matches, Comfortmaker uses the \"EA*5X\" family (EAM5X and EAA5X), with the Q5H9V, N5H9V, SoftSound B5H0V, B5H3V, C5H0V heat pumps and the Mainline C5H8T, all on R-454B.\u003c\/p\u003e\n\n\u003ch3\u003eWhy 3 tons suits so many homes\u003c\/h3\u003e\n\u003cp\u003eBungalows and two-storey homes in the region often have a furnace in the basement, a full duct network and a humid summer. At 3 tons, the system has the capacity to hold the temperature in this type of home, without short cycling. We always confirm it with a load calculation: a very well-insulated home may need less, an enlarged or heavily glazed home may need more.\u003c\/p\u003e\n\u003cp\u003eThe furnace stays in place with its blower, filters and ducts. If the outdoor unit is a heat pump, the furnace serves as backup heat when it is very cold, based on a threshold we program with you.\u003c\/p\u003e\n\n\u003ch3\u003eThree common mistakes when comparing ratings\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eComparing coils with each other instead of comparing systems.\u003c\/strong\u003e Two quotes that cite the same outdoor unit may describe different matches, with different ratings. Always ask for the full AHRI number.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConfusing nominal capacity with published capacity.\u003c\/strong\u003e The 3-ton size designates the size of the family; the match sheet gives the capacity actually measured in cooling and in heating at 47 °F, and it can differ.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eForgetting the furnace.\u003c\/strong\u003e The best rating is of no use if the blower does not supply the airflow the system requires. That is why an on-site visit comes before any firm quote: we test what the spec sheet cannot say about your home.\u003c\/p\u003e\n\n\u003ch3\u003eWhen you switch from electric heating to a heat pump\u003c\/h3\u003e\n\u003cp\u003eAn electric furnace or baseboard converts electricity into heat one for one. A heat pump moves heat that is already present in the outdoor air; that is why its efficiency exceeds direct heating in mild weather, and why that efficiency drops when it is very cold. This is why the furnace stays connected as backup. You keep the security of a second heating mode, without giving up the comfort of cool air in summer.\u003c\/p\u003e\n\n\u003ch3\u003eThe job, from start to finish\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company, active in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is carried out under RBQ licence 5645-9605-01.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eTaking the furnace dimensions, checking the blower and the electrical panel.\u003c\/li\u003e\n\u003cli\u003eInstalling the coil in the plenum, with a custom transition if needed; sealing the duct connections.\u003c\/li\u003e\n\u003cli\u003eInstalling the outdoor unit, brazed piping, nitrogen test, vacuum.\u003c\/li\u003e\n\u003cli\u003eConnecting the condensate drain and the thermostat.\u003c\/li\u003e\n\u003cli\u003eCommissioning, airflow adjustment and explanations.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eBefore you sign\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil and the outdoor unit must use the same refrigerant, R-454B, and be installed together.\u003c\/li\u003e\n\u003cli\u003eThe ratings apply to the certified match and to that match alone.\u003c\/li\u003e\n\u003cli\u003eThe furnace width and blower capacity must be suitable; we confirm this at your home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe brand\u003c\/h3\u003e\n\u003cp\u003eComfortmaker is a brand of International Comfort Products (ICP), a Carrier subsidiary. Its R-454B coils go with its central heat pumps and air conditioners, on a furnace or blower cabinet.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert incentive\u003c\/h3\u003e\n\u003cp\u003eThe matched Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation: we check it on the official list at the quote stage and prepare the application with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThe on-site estimate is free. We measure the furnace, check the electrical service and give you a written quote for the complete system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402707202340,"sku":"EAA5X37M17A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EAA5X_EAA5X37M17A_00_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765771","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-eaa5x37m17a-a-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}