{"product_id":"serpentin-devaporateur-comfortmaker-eaa5x42m21a-a-3-5-tonnes","title":"COMFORTMAKER EAA5X42M21A Evaporator A-Coil | 3.5 Tons","description":"\u003ch2\u003eComfortmaker EAA5X42M21A: 3.5 tons and 19-15\/16 in for homes with space\u003c\/h2\u003e\n\u003cp\u003eWith the \u003cstrong\u003eEAA5X42M21A\u003c\/strong\u003e, we leave the territory of the small sizes. This Comfortmaker evaporator coil is 3.5 tons (42,000 BTU\/h), uncased, running on R-454B refrigerant. Its 19-15\/16 in width makes it suited to large furnaces, in homes where the ducts serve many rooms: a good-sized two-storey home, a large single-storey, an enlarged suburban house.\u003c\/p\u003e\n\u003cp\u003eWe install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e. Here is how it differs from the other coils in the series, and what to examine in your home before choosing it.\u003c\/p\u003e\n\n\u003ch3\u003eMore surface, more air to supply\u003c\/h3\u003e\n\u003cp\u003eA coil of this size offers more exchange surface, and the system calls for a higher airflow than the small sizes. That airflow is not supplied by the coil: it is the furnace blower that has to push it through.\u003c\/p\u003e\n\u003cp\u003eDuring our visit, we therefore look at the blower capacity, the plenum size and the condition of the return ducts. A return that is too narrow chokes the system, and the coil ends up cooling poorly. This check comes before any other calculation, because no coil, however well chosen, makes up for a lack of air.\u003c\/p\u003e\n\n\u003ch3\u003eThree certified systems, three profiles\u003c\/h3\u003e\n\u003cp\u003eWhat stands out on this coil's sheet is the variety of published outdoor units. They do not all belong to the same size.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eB5H3V36*K*AAA\u003c\/strong\u003e, SoftSound heat pump, AHRI 218409547: cooling 32,800 BTU\/h, heating 34,800 BTU\/h at 47 °F, SEER2 20.0, HSPF2 9.5.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eB5H0V36*K*AAA\u003c\/strong\u003e, AHRI 218172257: cooling 33,200 BTU\/h, heating 35,800 BTU\/h at 47 °F, SEER2 17.5, HSPF2 9.0.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eB5H3V24*K*AAA\u003c\/strong\u003e, AHRI 218406651: cooling 22,600 BTU\/h, heating 25,400 BTU\/h at 47 °F, SEER2 20.5, HSPF2 9.5.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe third line shows that the same heat pump from the B5H3V family can also be published with this 3.5-ton coil, but with more modest measured capacities than those of the size 36 matches. The right combination is therefore not chosen using only the number of tons written on the coil: it is chosen by comparing the match sheets with the home's actual load. That is precisely the calculation we do with you.\u003c\/p\u003e\n\u003cp\u003eComfortmaker also publishes ENERGY STAR matches for the \"EA*5X\" family (EAM5X and EAA5X) with the Q5H9V, N5H9V, SoftSound B5H0V, B5H3V, C5H0V heat pumps and the Mainline C5H8T, all on R-454B.\u003c\/p\u003e\n\n\u003ch3\u003eChoosing between the 42M21A and the others\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X36M17A\u003c\/strong\u003e and \u003cstrong\u003eEAA5X37M17A\u003c\/strong\u003e: 3 tons and 16-7\/16 in. Smaller in capacity and in width.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X48M21A\u003c\/strong\u003e: 4 tons, same 19-15\/16 in width. For a two-storey home or a large single-storey with a finished basement.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X61M21A\u003c\/strong\u003e: 5 tons, also the same width.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X60M24A\u003c\/strong\u003e: 5 tons, 23-7\/16 in, the widest in the series.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X24M14A, 24M17A, 30M14A, 30M17A\u003c\/strong\u003e: 2 tons and 2.5 tons, smaller widths.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe rule of thumb: start from the furnace width, then choose the capacity that suits the home. A furnace 19-15\/16 in wide opens the door to this model, to the 4-ton model and to the 61M21A.\u003c\/p\u003e\n\n\u003ch3\u003eFor what kind of home, exactly?\u003c\/h3\u003e\n\u003cp\u003eTake a large suburban single-storey, with a basement finished as a family room and a wing added a few years ago. The ducts wind a long way, the rooms are many, and the windows are large. A small coil would be overwhelmed here; a 3.5-ton size offers the margin needed, provided the furnace keeps up.\u003c\/p\u003e\n\u003cp\u003eConversely, in a well-insulated bungalow of modest size, this coil would be too generous. An oversized system short cycles, cools without drying and leaves the air sticky. That is why we never sell a size on square footage alone: we do the load calculation, then discuss it with you, with the numbers in hand.\u003c\/p\u003e\n\u003cp\u003eWe will also tell you frankly if the most sensible choice for your home is to go down or up one step in the series.\u003c\/p\u003e\n\n\u003ch3\u003eShape and installation\u003c\/h3\u003e\n\u003cp\u003eThe EAA5X42M21A is an uncased A-coil, 19-7\/8 in high. It is installed vertically, with upflow or downflow air circulation. Horizontal installation is prohibited. The metering device is a TXV, which lets the coil adapt to the load. Without a factory casing, it is installed in the existing plenum or in a cabinet built on site.\u003c\/p\u003e\n\u003cp\u003eIf the furnace has a different width, we build an insulated transition to size.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand and range: Comfortmaker, EAA5X.\u003c\/li\u003e\n\u003cli\u003eNominal size: 3.5 tons (42,000 BTU\/h).\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-454B.\u003c\/li\u003e\n\u003cli\u003eDimensions W × H × D: 19-15\/16 × 19-7\/8 in.\u003c\/li\u003e\n\u003cli\u003eCondensate drain: 3\/4 in FPT primary and secondary connections.\u003c\/li\u003e\n\u003cli\u003e5 V refrigerant leak sensor (generation 2), factory-installed; incompatible with generation 1 dissipation boards.\u003c\/li\u003e\n\u003cli\u003e10-year limited parts warranty with registration within 90 days of installation, or 5 years without registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor an uncased coil, manual IM-EAA5X-05 calls for a furnace compatible with generation 2 dissipation.\u003c\/p\u003e\n\n\u003ch3\u003e\"Add-on\" heat pump: the coil's role\u003c\/h3\u003e\n\u003cp\u003eIn an \"add-on\" installation, the furnace keeps its blower, filters and heating elements. The coil fits into the plenum. In summer, the refrigerant evaporates in its tubes and picks up heat from the air; the condensation falls into the pan and goes to the drain. In winter, with a heat pump, the cycle reverses and the coil gives up heat to the air. The furnace steps in when the outdoor temperature falls below the threshold we program with you.\u003c\/p\u003e\n\u003cp\u003eThe coil has no rating on its own: SEER2 and HSPF2 describe the certified system, which the AHRI number identifies.\u003c\/p\u003e\n\n\u003ch3\u003eOur work at your home\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company, based in Montreal for more than fifteen years, which carries out its refrigeration, ventilation and electrical work under RBQ licence 5645-9605-01.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eMeasuring the furnace, checking the blower, the plenum and the electrical panel.\u003c\/li\u003e\n\u003cli\u003eInstalling the coil, a transition if needed, sealing the duct connections.\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit, brazed piping, nitrogen leak test and vacuum.\u003c\/li\u003e\n\u003cli\u003eConnecting the drain and the thermostat.\u003c\/li\u003e\n\u003cli\u003eCommissioning, airflow adjustment, explanation of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eWhat to confirm before buying\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil and the outdoor unit use R-454B and are installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe ratings apply to the certified match, and to that match alone.\u003c\/li\u003e\n\u003cli\u003eThe furnace must have the right width and a blower capable of the required airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe Comfortmaker brand\u003c\/h3\u003e\n\u003cp\u003eComfortmaker is a brand of International Comfort Products (ICP), a Carrier subsidiary. Its R-454B evaporator coils go with its central heat pumps and air conditioners, on a furnace or blower cabinet.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert incentive\u003c\/h3\u003e\n\u003cp\u003eThe matched Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We read it from the official list at the quote stage, then prepare the application with you.\u003c\/p\u003e\n\n\u003ch3\u003eFree estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402708021540,"sku":"EAA5X42M21A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EAA5X_EAA5X42M21A_00_3_5_TONNES_42000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765770","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-eaa5x42m21a-a-3-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}