{"product_id":"serpentin-devaporateur-comfortmaker-eaa5x48m21a-a-4-tonnes","title":"COMFORTMAKER EAA5X48M21A Evaporator A-Coil | 4 Tons","description":"\u003ch2\u003eFour tons on a furnace: what the Comfortmaker EAA5X48M21A requires\u003c\/h2\u003e\n\u003cp\u003eA 4-ton system is not just a small system made bigger. It moves a lot of air, it draws more electricity outdoors, and it puts the furnace to the test. The \u003cstrong\u003eEAA5X48M21A\u003c\/strong\u003e is the 4-ton (48,000 BTU\/h) Comfortmaker evaporator coil of the EAA5X range: uncased, A-type, on R-454B refrigerant, 19-15\/16 in wide and 19-7\/8 in high.\u003c\/p\u003e\n\u003cp\u003eAirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e. Before we talk spec sheets, here are the three questions we ask every homeowner.\u003c\/p\u003e\n\n\u003ch3\u003eFirst question: does the home really need 4 tons?\u003c\/h3\u003e\n\u003cp\u003eThis size serves a two-storey home, or a large single-storey with a finished basement. At this scale, a miscalculation is costly: too small, and the system can't handle the hottest days; too big, and it short cycles and leaves the humidity in place. So we do a complete load calculation before talking about a model, taking into account the windows, the insulation and the rooms served.\u003c\/p\u003e\n\u003cp\u003eSometimes the result leads us toward 3.5 tons, or toward a different split of the home. We tell you frankly.\u003c\/p\u003e\n\n\u003ch3\u003eSecond question: can the blower keep up?\u003c\/h3\u003e\n\u003cp\u003eThe more the capacity goes up, the more the required airflow climbs. That airflow comes from the furnace blower, not from the coil. If it is too weak, the coil can freeze, or the home lacks comfort. At the visit, we check the blower capacity, the plenum size and the condition of the return ducts.\u003c\/p\u003e\n\u003cp\u003eThe 19-15\/16 in width must also line up with the furnace. A narrower furnace can receive the coil thanks to a transition that we build and insulate on site.\u003c\/p\u003e\n\n\u003ch3\u003eThird question: what does the system sheet say?\u003c\/h3\u003e\n\u003cp\u003eComfortmaker publishes two matches, with these size 48 outdoor units:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eQ5H9V48*K*AAA\u003c\/strong\u003e: AHRI 217954402. Cooling of 43,500 BTU\/h, heating of 49,000 BTU\/h at 47 °F, SEER2 15.2, HSPF2 9.0.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eN5H9V48*K*AAA\u003c\/strong\u003e: AHRI 217954397. Same capacities and same ratings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese values are specific to the match. The coil has no efficiency rating on its own, and the same outdoor units matched with a different coil carry different AHRI numbers. This is the number to compare between quotes, and it is the one incentive programs ask for.\u003c\/p\u003e\n\n\u003ch3\u003eWhere the 48M21A sits in the series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X42M21A\u003c\/strong\u003e: 3.5 tons, same width. The previous step if the load is lower.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X61M21A\u003c\/strong\u003e: 5 tons, still 19-15\/16 in. The next step if the home needs more.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X60M24A\u003c\/strong\u003e: 5 tons, but 23-7\/16 in wide.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X36M17A\u003c\/strong\u003e and \u003cstrong\u003eEAA5X37M17A\u003c\/strong\u003e: 3 tons, 16-7\/16 in.\u003c\/li\u003e\n\u003cli\u003eThe 2-ton and 2.5-ton sizes (24M14A, 24M17A, 30M14A, 30M17A) serve smaller homes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis coil therefore shares its width with two neighbours: the 3.5-ton and one of the two 5-ton models. That is handy, because a furnace of this width can take either one depending on the load.\u003c\/p\u003e\n\n\u003ch3\u003eTwo smaller systems, or one large one?\u003c\/h3\u003e\n\u003cp\u003eIn some homes, a single high-capacity system is not the right answer. A large multi-storey home whose upper floor is poorly insulated, or a home with two wings, is sometimes better served by two smaller systems, each on its own furnace. We assess this option with you at the visit, rather than automatically selling the biggest unit in the series.\u003c\/p\u003e\n\u003cp\u003eIf a single furnace serves the whole home and the calculated load justifies it, the 48M21A is then a logical choice: it keeps a single thermostat, a single duct network and a single outdoor unit to maintain.\u003c\/p\u003e\n\n\u003ch3\u003eThe mechanics of the A-coil\u003c\/h3\u003e\n\u003cp\u003eIts two sloped faces meet like a roof. Furnace air passes through, and the refrigerant evaporating in the tubes picks up its heat. The moisture in the air condenses and falls into the pan; it leaves through the 3\/4 in FPT drain connections, primary and secondary. The metering device is a TXV.\u003c\/p\u003e\n\u003cp\u003eOnly two orientations are permitted: vertical upflow or vertical downflow. The manufacturer prohibits horizontal installation. Supplied uncased, the coil goes into the existing plenum or into a cabinet built to size.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand: Comfortmaker, EAA5X range.\u003c\/li\u003e\n\u003cli\u003eType: uncased evaporator coil.\u003c\/li\u003e\n\u003cli\u003eNominal size: 4 tons, 48,000 BTU\/h.\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-454B.\u003c\/li\u003e\n\u003cli\u003eDimensions W × H × D: 19-15\/16 × 19-7\/8 in.\u003c\/li\u003e\n\u003cli\u003eGeneration 2, 5 V refrigerant sensor, factory-mounted, incompatible with generation 1 dissipation boards.\u003c\/li\u003e\n\u003cli\u003eManufacturer's warranty: 10-year limited parts warranty with registration within 90 days of installation, 5 years without registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eManual IM-EAA5X-05 requires, for an uncased coil, a furnace compatible with generation 2 dissipation. ENERGY STAR matches for the \"EA*5X\" family (EAM5X and EAA5X) also exist with the SoftSound B5H0V, B5H3V, C5H0V heat pumps and the Mainline C5H8T, all on R-454B.\u003c\/p\u003e\n\n\u003ch3\u003eA heat pump that does not replace the furnace\u003c\/h3\u003e\n\u003cp\u003eIn a large home, the furnace keeps a valuable role. It keeps its blower, filters and ducts, and it serves as backup heat when the outdoor temperature falls below a threshold we program with you. The heat pump handles most of the heating season, and the furnace takes over during the coldest spells.\u003c\/p\u003e\n\u003cp\u003eIn summer, the same system cools every floor through the same ducts, and the air becomes drier, which makes July's humid heat more bearable. For large multi-storey homes, a well-adjusted thermostat helps limit the differences between the ground floor and the upper floor.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation and electrical\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company, based in Montreal for more than fifteen years; we carry out our refrigeration, ventilation and electrical work under RBQ licence 5645-9605-01. At this size, the electrical service deserves particular attention, because the outdoor unit needs a suitable circuit.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eMeasuring the furnace, checking the blower and the electrical panel.\u003c\/li\u003e\n\u003cli\u003eInstalling the coil in the plenum, insulated transition if needed, sealing the duct connections.\u003c\/li\u003e\n\u003cli\u003eInstalling the outdoor unit on a pad or bracket, brazing, nitrogen leak test, vacuum.\u003c\/li\u003e\n\u003cli\u003eConnecting the condensate drain and the thermostat.\u003c\/li\u003e\n\u003cli\u003eCommissioning, airflow adjustment and explanations at your home.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003ePoints to check before buying\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCoil and outdoor unit must share R-454B and be installed together.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply to the certified match.\u003c\/li\u003e\n\u003cli\u003eThe furnace must have the right width and blower; we confirm this at the visit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAbout Comfortmaker\u003c\/h3\u003e\n\u003cp\u003eComfortmaker is a brand of International Comfort Products (ICP), a Carrier subsidiary. Its R-454B evaporator coils go with its central heat pumps and air conditioners, on a furnace or blower cabinet.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert incentive\u003c\/h3\u003e\n\u003cp\u003eThe matched Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We consult the official list at the quote stage and prepare the application with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402708742436,"sku":"EAA5X48M21A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EAA5X_EAA5X48M21A_00_4_TONNES_48000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765769","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-eaa5x48m21a-a-4-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}