{"product_id":"serpentin-devaporateur-comfortmaker-eaa5x60m24a-a-5-tonnes","title":"COMFORTMAKER EAA5X60M24A Evaporator A-Coil | 5 Tons","description":"\u003ch2\u003eEAA5X60M24A: the widest Comfortmaker coil, 5 tons and 23-7\/16 in\u003c\/h2\u003e\n\u003cp\u003eIn the EAA5X series, one coil stands out for its dimensions: the \u003cstrong\u003eEAA5X60M24A\u003c\/strong\u003e. It offers 5 tons of nominal capacity (60,000 BTU\/h) in a body 23-7\/16 in wide by 19-7\/8 in high, which makes it the widest in the family. It is an A-type, uncased coil, and it runs on R-454B refrigerant.\u003c\/p\u003e\n\u003cp\u003eThis is a coil for the large furnaces of large homes. AirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhy width is the first criterion\u003c\/h3\u003e\n\u003cp\u003eFor a 5-ton, two sizes exist in the series: this one, 23-7\/16 in wide, and the \u003cstrong\u003eEAA5X61M21A\u003c\/strong\u003e, narrower at 19-15\/16 in. They offer the same nominal capacity; what separates them is the furnace they are installed on. So we choose first by measuring the plenum, then we check that the rest of the system keeps up.\u003c\/p\u003e\n\u003cp\u003eA coil installed on a narrower plenum requires a transition. We build it from insulated sheet metal, but the result is better when the widths match. That is why we measure before ordering, never after.\u003c\/p\u003e\n\n\u003ch3\u003eWhat Comfortmaker publishes for this coil\u003c\/h3\u003e\n\u003cp\u003eTwo matches are published, with size 48 heat pumps:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eQ5H9V48*K*AAA\u003c\/strong\u003e: AHRI number 217954416. Cooling of 44,500 BTU\/h, heating of 48,500 BTU\/h at 47 °F, SEER2 15.2, HSPF2 9.0.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eN5H9V48*K*AAA\u003c\/strong\u003e: AHRI number 217954411, with the same capacities and the same ratings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA coil is only half of a system: the rating depends on the whole. We go over these numbers with you, with no promise that isn't on the sheet, and we give you both match sheets if you want to compare them.\u003c\/p\u003e\n\n\u003ch3\u003eTwo checks specific to large capacities\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThe electrical service.\u003c\/strong\u003e The outdoor unit requires a dedicated circuit, and the panel must be able to accommodate it. In an older home, where the panel has already been stretched, this is sometimes the real subject of the project. We look at it at the first visit, before talking about price.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAir distribution.\u003c\/strong\u003e The system must reach its nominal airflow, and that depends on the blower, the plenum and the return ducts. A blower that is too weak leaves the coil too cold and the home unevenly cooled.\u003c\/p\u003e\n\u003cp\u003eWe also tell you frankly if two smaller systems would serve your home better. Five tons is the largest common residential size; it is not always the right answer, even for a large home.\u003c\/p\u003e\n\n\u003ch3\u003eA large home, a large duct network\u003c\/h3\u003e\n\u003cp\u003eA wide coil is only worth the air you give it. In a home enlarged over the years, it is not unusual for ducts to have been extended without anyone recalculating the network: insufficient return air, an original plenum that is too small, blocked registers. Before installing a 5-ton, we review these elements, because the coil cannot make up for a network that chokes.\u003c\/p\u003e\n\u003cp\u003eSometimes the solution is to add a return air or rework the plenum, which is done during the installation. We tell you at the quote stage and not on the day of the job.\u003c\/p\u003e\n\n\u003ch3\u003eComparing with the rest of the series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X61M21A\u003c\/strong\u003e: same 5-ton capacity, but 19-15\/16 in wide. Published ratings slightly different for the match.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X48M21A\u003c\/strong\u003e: 4 tons, 19-15\/16 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X42M21A\u003c\/strong\u003e: 3.5 tons, 19-15\/16 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X36M17A\u003c\/strong\u003e and \u003cstrong\u003eEAA5X37M17A\u003c\/strong\u003e: 3 tons, 16-7\/16 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X30M14A, 30M17A, 24M14A, 24M17A\u003c\/strong\u003e: 2.5-ton and 2-ton sizes, for more modest homes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe shape, the positions and the metering device\u003c\/h3\u003e\n\u003cp\u003eThe coil is an A-coil: two sloped faces that meet at the top. Air enters at the centre and passes through each face. The manufacturer allows the vertical position, upflow or downflow, and prohibits horizontal. The metering device is a TXV. Condensate water leaves through 3\/4 in FPT drain connections, primary and secondary.\u003c\/p\u003e\n\u003cp\u003eSince there is no factory cabinet, the coil is installed in the existing plenum or in a cabinet built on site, which leaves some freedom when space is tight.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer's sheet\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComfortmaker, EAA5X range, uncased evaporator coil.\u003c\/li\u003e\n\u003cli\u003eNominal size: 5 tons (60,000 BTU\/h).\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-454B.\u003c\/li\u003e\n\u003cli\u003eDimensions W × H × D: 23-7\/16 × 19-7\/8 in.\u003c\/li\u003e\n\u003cli\u003eLeak detection by a generation 2, 5 V refrigerant sensor, factory-installed; it does not work with generation 1 dissipation boards.\u003c\/li\u003e\n\u003cli\u003e10-year limited parts warranty with registration within 90 days of installation, 5 years without registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eManual IM-EAA5X-05 states that the furnace must be compatible with generation 2 dissipation. The ENERGY STAR matches published for the \"EA*5X\" families (EAM5X and EAA5X) also include the SoftSound B5H0V, B5H3V, C5H0V heat pumps and the Mainline C5H8T, all on R-454B.\u003c\/p\u003e\n\n\u003ch3\u003eThe furnace's role stays whole\u003c\/h3\u003e\n\u003cp\u003eWith a heat pump, the furnace keeps its blower, filters and ducts. It becomes the backup heat for the coldest periods, based on a threshold we program with you. In summer, the system cools every floor and dries the air. A single thermostat controls both seasons, and a single outdoor unit replaces all the window units.\u003c\/p\u003e\n\u003cp\u003eNote that the coil has no efficiency rating of its own. The SEER2 and HSPF2 ratings belong to the matched system, and the AHRI number is what lets you compare two quotes and file an incentive application.\u003c\/p\u003e\n\n\u003ch3\u003eHow the job unfolds\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company, based in Montreal for more than fifteen years, and its refrigeration, ventilation and electrical work is carried out under RBQ licence 5645-9605-01.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eMeasuring the furnace, checking the blower, the plenum and the electrical panel.\u003c\/li\u003e\n\u003cli\u003eInstalling the coil, custom transition if needed, sealing the duct connections.\u003c\/li\u003e\n\u003cli\u003eInstalling the outdoor unit on a pad or bracket, brazed piping, nitrogen leak test, vacuum.\u003c\/li\u003e\n\u003cli\u003eConnecting the condensate drain and the thermostat.\u003c\/li\u003e\n\u003cli\u003eCommissioning, airflow adjustment and explanation of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eTo confirm before buying\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCoil and outdoor unit use the same refrigerant, R-454B, and are installed together.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply to the certified match only.\u003c\/li\u003e\n\u003cli\u003eThe furnace must offer the right width and blower; we confirm this at the visit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eComfortmaker\u003c\/h3\u003e\n\u003cp\u003eComfortmaker is a brand of International Comfort Products (ICP), a Carrier subsidiary. Its R-454B evaporator coils go with its central heat pumps and air conditioners, installed on a furnace or blower cabinet.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert incentive\u003c\/h3\u003e\n\u003cp\u003eThe matched Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We check it on the official list at the quote stage and prepare the application with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402709496100,"sku":"EAA5X60M24A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EAA5X_EAA5X60M24A_00_5_TONNES_60000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765770","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-eaa5x60m24a-a-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}