{"product_id":"serpentin-devaporateur-comfortmaker-eaa5x61m21a-a-5-tonnes","title":"COMFORTMAKER EAA5X61M21A Evaporator A-Coil | 5 Tons","description":"\u003ch2\u003e5 tons in a standard-width furnace: the Comfortmaker EAA5X61M21A\u003c\/h2\u003e\n\u003cp\u003eLarge capacity does not always mean large size. The \u003cstrong\u003eEAA5X61M21A\u003c\/strong\u003e offers the 5 tons (60,000 BTU\/h) that very large homes require, but in a width of 19-15\/16 in, the same as the 3.5-ton and 4-ton coils in the series. For anyone with a standard-width furnace in a large home, that is good news: no need for an oversized plenum.\u003c\/p\u003e\n\u003cp\u003eThis Comfortmaker evaporator coil is A-type, uncased, and runs on R-454B refrigerant. We install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003e61M21A or 60M24A: choosing between two 5-tons\u003c\/h3\u003e\n\u003cp\u003eThe series has two 5-ton coils. The \u003cstrong\u003eEAA5X60M24A\u003c\/strong\u003e measures 23-7\/16 in wide; this one, 19-15\/16 in. Same nominal capacity, same refrigerant, same TXV metering device: so you tell them apart with a tape measure. A furnace 19-15\/16 in wide takes the 61M21A directly. A wider furnace would go to the 60M24A. In between, a transition can solve the case, but we prefer to avoid it when possible.\u003c\/p\u003e\n\u003cp\u003eThe published ratings differ slightly from one model to the other: each coil has its own AHRI numbers and its own match sheets. These values apply to the complete system, not to the coil alone, and we give you the sheets for both models if you want to put them side by side.\u003c\/p\u003e\n\n\u003ch3\u003eThe certified matches\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eQ5H9V48*K*AAA\u003c\/strong\u003e: AHRI 217954430. Cooling of 45,000 BTU\/h, heating of 49,000 BTU\/h at 47 °F, SEER2 15.5, HSPF2 9.0.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eN5H9V48*K*AAA\u003c\/strong\u003e: AHRI 217954425. Same capacities and same ratings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor your quote file, note the exact AHRI number and model number. Comfortmaker also publishes ENERGY STAR matches under the \"EA*5X\" family (EAM5X and EAA5X) with the Q5H9V, N5H9V, SoftSound B5H0V, B5H3V, C5H0V heat pumps and the Mainline C5H8T, all on R-454B.\u003c\/p\u003e\n\n\u003ch3\u003eWhat a home this size requires\u003c\/h3\u003e\n\u003cp\u003eThe 5-ton size is aimed at large homes, properties with a finished basement and homes enlarged over the years. It is the largest common residential size. Two points are checked before anything else: the electrical service, which must accommodate the outdoor unit's circuit, and the air distribution, which must reach the airflow the system requires.\u003c\/p\u003e\n\u003cp\u003eSo we look at the panel, the blower, the plenum and the returns. And if two smaller systems serve the home better, we tell you: we don't sell a big unit by reflex.\u003c\/p\u003e\n\n\u003ch3\u003ePosition in the series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X48M21A\u003c\/strong\u003e: 4 tons, same width. If the home's load is a little lower.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X42M21A\u003c\/strong\u003e: 3.5 tons, same width.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X60M24A\u003c\/strong\u003e: 5 tons, 23-7\/16 in wide.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X36M17A\u003c\/strong\u003e, \u003cstrong\u003eEAA5X37M17A\u003c\/strong\u003e: 3 tons, 16-7\/16 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X30M14A\u003c\/strong\u003e, \u003cstrong\u003e30M17A\u003c\/strong\u003e, \u003cstrong\u003e24M14A\u003c\/strong\u003e, \u003cstrong\u003e24M17A\u003c\/strong\u003e: 2.5 tons and 2 tons for smaller homes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA large home, two scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFirst scenario: one large system.\u003c\/strong\u003e The home is served by a single furnace and a complete duct network. The load calculation confirms the need for 5 tons. The 61M21A is then a natural choice, with a single thermostat and one outdoor unit to maintain.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSecond scenario: we prefer to split.\u003c\/strong\u003e The home has two wings or two floors with different needs, or a single furnace can't distribute the air well everywhere. Two systems of lower capacity, each on its own furnace, sometimes give better comfort. We assess this choice with you rather than starting from the maximum capacity.\u003c\/p\u003e\n\u003cp\u003eIn both cases, the condition of the ducts, the returns and the electrical panel weighs as much as the coil in the final decision.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is worth knowing about the leak sensor\u003c\/h3\u003e\n\u003cp\u003eThis coil is supplied with a 5 V refrigerant sensor, generation 2, factory-installed. It works with generation 2 dissipation boards, and not with generation 1. In practice, this means your furnace's compatibility is checked before purchase: we make a note of it at the visit and confirm it before placing the order.\u003c\/p\u003e\n\n\u003ch3\u003eShape, positions, metering device and drain\u003c\/h3\u003e\n\u003cp\u003eThe coil is an A-coil: two sloped faces that form a roof. Air passes through each of them. The permitted positions are vertical upflow and vertical downflow; horizontal is prohibited. A TXV metering device doses the refrigerant, and condensation drains through 3\/4 in FPT primary and secondary drain connections.\u003c\/p\u003e\n\u003cp\u003eWithout a factory cabinet, the coil is installed in the existing plenum or in a cabinet built on site, depending on the space available.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer and range: Comfortmaker EAA5X.\u003c\/li\u003e\n\u003cli\u003eNominal size: 5 tons, 60,000 BTU\/h.\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-454B.\u003c\/li\u003e\n\u003cli\u003eDimensions W × H × D: 19-15\/16 × 19-7\/8 in.\u003c\/li\u003e\n\u003cli\u003eGeneration 2, 5 V refrigerant leak sensor, factory-installed; not compatible with generation 1 dissipation boards.\u003c\/li\u003e\n\u003cli\u003e10-year limited parts warranty with registration within 90 days of installation; 5 years without registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eManual IM-EAA5X-05 requires a furnace compatible with generation 2 dissipation for an uncased coil.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the heat pump changes at home\u003c\/h3\u003e\n\u003cp\u003eAn electric furnace turns each kilowatt-hour into an equal amount of heat. A heat pump moves heat from outside to inside; it delivers more heat than the electricity it uses when the weather is mild, and that efficiency drops with the cold. Hence the furnace's backup role: it takes over below a threshold that we set with you.\u003c\/p\u003e\n\u003cp\u003eIn summer, the same system cools every room and dehumidifies the air. The coil has no rating on its own: SEER2, HSPF2 and capacities belong to the certified system.\u003c\/p\u003e\n\n\u003ch3\u003eWhat we do on installation day\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work falls under RBQ licence 5645-9605-01.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eWe measure the furnace, check the blower and look at the electrical panel.\u003c\/li\u003e\n\u003cli\u003eWe install the coil in the plenum, with a transition if needed, and seal the duct connections.\u003c\/li\u003e\n\u003cli\u003eWe set the outdoor unit, braze the piping, run the nitrogen test and pull a vacuum.\u003c\/li\u003e\n\u003cli\u003eWe connect the condensate drain and the thermostat.\u003c\/li\u003e\n\u003cli\u003eWe start up the system, adjust the airflow and explain the whole setup.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eThree final checks\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil and outdoor unit must use R-454B and be installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe ratings apply to the certified match.\u003c\/li\u003e\n\u003cli\u003eThe furnace width and its blower must be suitable; we confirm this at your home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWho Comfortmaker is\u003c\/h3\u003e\n\u003cp\u003eComfortmaker is a brand of International Comfort Products (ICP), a Carrier subsidiary. Its R-454B coils pair with its central heat pumps and air conditioners, on a furnace or blower cabinet.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert incentive\u003c\/h3\u003e\n\u003cp\u003eThe matched Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation: we check it on the official list at the quote stage and prepare the application with you.\u003c\/p\u003e\n\n\u003ch3\u003eFree estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402710315300,"sku":"EAA5X61M21A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EAA5X_EAA5X61M21A_00_5_TONNES_60000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765769","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-eaa5x61m21a-a-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}