{"product_id":"serpentin-devaporateur-comfortmaker-eam5x24m14a-a-2-tonnes","title":"COMFORTMAKER EAM5X24M14A Evaporator A-Coil | 2 Tons","description":"\u003ch2\u003eThe EAM5X24M14A: a 2-ton Comfortmaker evaporator coil built for narrow furnaces\u003c\/h2\u003e\n\u003cp\u003eIn many Montreal homes, the furnace is not housed in a large, open basement: it sits in an alcove, a utility closet or a corner wedged between a concrete wall and the hot-water boiler. The \u003cstrong\u003eComfortmaker EAM5X24M14A evaporator coil\u003c\/strong\u003e was designed for exactly these tight spots. Its 14-3\/16 in wide cabinet is one of the slimmest in the series, in a 2-ton size (24,000 BTU\/h) with R-454B refrigerant.\u003c\/p\u003e\n\u003cp\u003eWe install it in Montreal, Laval, Longueuil, the North Shore and the South Shore, always after measuring the furnace on site.\u003c\/p\u003e\n\n\u003ch3\u003eWhy the cabinet width decides everything\u003c\/h3\u003e\n\u003cp\u003eThe cabinet sits on top of the furnace, in the air outlet plenum. If the coil is wider than the unit, air slips out through the sides and the seal suffers; if it is narrower, a transition piece has to be built. At 14-3\/16 in, this model fits small-footprint furnaces without any improvised fixes.\u003c\/p\u003e\n\u003cp\u003eIts height is 25-13\/16 in, and it weighs 50.1 lb: a reasonable weight to handle on a basement staircase or through a ceiling hatch.\u003c\/p\u003e\n\n\u003ch3\u003eA word on the A shape and the three positions\u003c\/h3\u003e\n\u003cp\u003eThe two faces of the coil meet at the top, like a roof with two slopes. The warm or cool air from the blower passes through these faces before moving on into the ducts. The manufacturer allows upflow, downflow or horizontal installation, which helps when the furnace lies on its side in a crawl space or hangs in an attic.\u003c\/p\u003e\n\u003cp\u003eTwo FRTP drain pans, one vertical and one horizontal, are supplied, both sloped so the water runs toward the drain. The suction connection is 5\/8 in and the expansion device is a TXV type.\u003c\/p\u003e\n\n\u003ch3\u003eCooling with 2 tons: what to expect\u003c\/h3\u003e\n\u003cp\u003eA system of this size suits a well-insulated bungalow, a plex ground-floor unit or a single storey of a townhouse. More than the number of square feet, it is the windows, the orientation, the roof insulation and the air leaks that decide. That is why we run a load calculation before proposing anything.\u003c\/p\u003e\n\u003cp\u003eA well-matched capacity avoids the on-off cycling that leaves the air cool but damp. The result is felt most during long spells of muggy heat.\u003c\/p\u003e\n\n\u003ch3\u003eThe certified systems for this model\u003c\/h3\u003e\n\u003cp\u003eLike any coil, this one has no rating of its own; the following figures belong to the published systems:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eB5H3V24*K*AAA\u003c\/strong\u003e, AHRI number 218405915: 21,600 BTU\/h cooling, 26,600 BTU\/h heating at 47 °F, SEER2 19.0, HSPF2 9.5.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eC5H0V24*K*AAA\u003c\/strong\u003e, AHRI number 215666934: 22,800 BTU\/h cooling, 24,000 BTU\/h heating at 47 °F, SEER2 17.0, HSPF2 9.0.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eC5H8T24*K*AAA\u003c\/strong\u003e, AHRI number 216364538: 22,200 BTU\/h cooling, 25,000 BTU\/h heating at 47 °F, SEER2 15.5, HSPF2 8.0.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe first system shows the highest ratings of the three; the other two are justified by the choice of outdoor unit line, depending on noise, budget and the space available in the yard.\u003c\/p\u003e\n\n\u003ch3\u003eChoosing between the EAM5X24M14A and its neighbours\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eVersus the EAM5X24M17A\u003c\/strong\u003e: same 2-ton capacity, same B5H3V24*K*AAA outdoor unit, but the cabinet of the latter is 17-1\/2 in wide. Your furnace settles the question.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eVersus the EAM5X25M17A\u003c\/strong\u003e: also 2 tons, but at 17-1\/2 in and paired with the Q5H9V24*K*AAA.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eVersus the EAM5X19M17A\u003c\/strong\u003e: 1.5 tons, smaller, for low-load spaces.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eVersus the EAM5X30M14A\u003c\/strong\u003e: same width of 14-3\/16 in, but 2.5 tons for a house that needs more.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAll of them share R-454B, the TXV expansion device and Comfortmaker manufacturing.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the add-on heat pump does\u003c\/h3\u003e\n\u003cp\u003ePaired with a heat pump, the coil lets you heat in mild temperatures with the outdoor unit, while the furnace stays in reserve for the deep cold. The changeover threshold is programmed with you at start-up. If your furnace is electric, the difference in consumption can be significant, because the heat pump moves heat instead of simply producing it.\u003c\/p\u003e\n\n\u003ch3\u003eThe installation, step by step\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, under RBQ licence 5645-9605-01. For this coil:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace dimensions, checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003esetting the coil in the plenum, with an insulated transition built on site if necessary, then sealing the joints;\u003c\/li\u003e\n\u003cli\u003einstalling the outdoor unit, brazing the piping, nitrogen pressure test and vacuum pull;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003estart-up, airflow adjustment and a walk-through of how it all works with you.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhen the work space is limited\u003c\/h3\u003e\n\u003cp\u003eA furnace housed in a closet raises a practical question: how do you reach the plenum, the drain and the connections? During the visit, we look at the clearance above the unit, the path for the piping and the place where condensation can drain without backing up. It is better to spot an obstacle before delivery than on installation day.\u003c\/p\u003e\n\u003cp\u003eA party wall, a closet door fitted to the millimetre or a plumbing pipe that crosses the plenum are easy to handle when they are known in advance. We take photos, note the dimensions, then confirm the plan in writing.\u003c\/p\u003e\n\n\u003ch3\u003eWhat you will notice after installation\u003c\/h3\u003e\n\u003cp\u003eFrom the first hot day, the difference is felt mostly in the humidity: the air is drier, the house is more even from room to room, and you stop hauling a window air conditioner from one floor to another. In winter, if a heat pump is connected, the furnace runs far less often.\u003c\/p\u003e\n\u003cp\u003eFinally, think about basic maintenance: a clean filter at regular intervals and a clear condensate drain protect the coil and extend its life. We explain where these points are during start-up.\u003c\/p\u003e\n\n\u003ch3\u003eRefrigerant safety and warranty\u003c\/h3\u003e\n\u003cp\u003eThe coil ships with a leak sensor and its harness already installed at the factory, while the dissipation board, the enclosure and the power harness are in the parts box. The manufacturer grants a 10-year limited warranty on parts if the unit is registered within 90 days of installation; without registration, the term drops to 5 years.\u003c\/p\u003e\n\n\u003ch3\u003eTo confirm before ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe outdoor unit must be R-454B and installed at the same time as the coil.\u003c\/li\u003e\n\u003cli\u003eThe ratings apply to the certified system, not to the coil alone.\u003c\/li\u003e\n\u003cli\u003eThe blower must be able to move the required volume of air.\u003c\/li\u003e\n\u003cli\u003eThe furnace width must be confirmed: if the gap is significant, the transition is built on site.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert subsidy\u003c\/h3\u003e\n\u003cp\u003eThis Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your personal situation. We check the official list when we prepare your quote and put the application together with you.\u003c\/p\u003e\n\n\u003ch3\u003ePlan a visit\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free in-home estimate: we measure your furnace, examine the electrical service and give you a written quote for the complete Comfortmaker system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the work.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402716508452,"sku":"EAM5X24M14A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EAM5X_EAM5X24M14A_00_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765768","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-eam5x24m14a-a-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}