{"product_id":"serpentin-devaporateur-comfortmaker-eam5x30m14a-a-2-5-tonnes","title":"COMFORTMAKER EAM5X30M14A Evaporator A-Coil | 2.5 Tons","description":"\u003ch2\u003eEAM5X30M14A: 2.5 tons in a slim cabinet, for the average home with a compact furnace\u003c\/h2\u003e\n\u003cp\u003eThe 2.5-ton size sits in the middle of the EAM5X range. With the \u003cstrong\u003eComfortmaker EAM5X30M14A evaporator coil\u003c\/strong\u003e, it also fits in a cabinet 14-3\/16 in wide: this is the combination you look for when the house needs a little more than a small system, but the furnace stays modest in size.\u003c\/p\u003e\n\u003cp\u003eThis nominal 30,000 BTU\/h model, with R-454B refrigerant, is installed by AirGreen in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eTwo numbers not to confuse\u003c\/h3\u003e\n\u003cp\u003eThe first is the \u003cstrong\u003enominal size\u003c\/strong\u003e: 2.5 tons, or 30,000 BTU\/h. This is the label of the family, the one used to classify coils. The second is the \u003cstrong\u003epublished capacity for a system\u003c\/strong\u003e: for this coil paired with a Q5H9V24*K*AAA unit, it is 22,200 BTU\/h cooling. The two do not contradict each other, but they are not interchangeable either.\u003c\/p\u003e\n\u003cp\u003eWhen you compare quotes, always ask which capacity is being quoted. A round number on a brochure does not replace the certificate for the system.\u003c\/p\u003e\n\n\u003ch3\u003eThe certified systems\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eQ5H9V24*K*AAA\u003c\/strong\u003e, AHRI 217953796: 22,200 BTU\/h cooling, 23,800 BTU\/h heating at 47 °F, SEER2 15.2, HSPF2 9.0.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eN5H9V24*K*AAA\u003c\/strong\u003e, AHRI 217953789: same capacities and same ratings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOnly two units are published for this coil, against three for some 2-ton models. The choice is therefore simple, and it comes down mostly to where the unit sits in the yard, availability and budget.\u003c\/p\u003e\n\n\u003ch3\u003eThe piping: a 3\/4 in suction connection\u003c\/h3\u003e\n\u003cp\u003eThis coil has a 3\/4 in suction connection. This directly affects the refrigerant piping between the furnace and the outdoor unit: the tubes must match. Our technicians check the route, the length and the diameter before drilling through the foundation wall.\u003c\/p\u003e\n\u003cp\u003eThe connections are brazed, then the piping goes through a nitrogen leak test and a vacuum pull before the refrigerant is released.\u003c\/p\u003e\n\n\u003ch3\u003eDimensions, weight and configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWidth 14-3\/16 in, height 25-13\/16 in; net weight 54.5 lb.\u003c\/li\u003e\n\u003cli\u003eA-coil in an insulated cabinet, with TXV expansion device.\u003c\/li\u003e\n\u003cli\u003eCan be installed upflow, downflow or horizontal.\u003c\/li\u003e\n\u003cli\u003eTwo FRTP condensate pans, vertical and horizontal, sloped.\u003c\/li\u003e\n\u003cli\u003eFactory-installed A2L leak sensor, with a harness; the dissipation board, the enclosure and the power harness are in the parts box.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow to choose between this model and its neighbours\u003c\/h3\u003e\n\u003cp\u003eThe choice comes down to three criteria: capacity, width and outdoor unit.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eEAM5X30M17A\u003c\/strong\u003e: same 2.5-ton capacity, same Q5H9V24*K*AAA and N5H9V24*K*AAA units, but a wider cabinet, at 17-1\/2 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAM5X24M14A\u003c\/strong\u003e: same width of 14-3\/16 in, but 2 tons, paired with the B5H3V24*K*AAA.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e3-ton models\u003c\/strong\u003e: EAM5X36M17A, EAM5X37M17A and EAM5X36M21A, for heavier loads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf the load calculation lands on the line between 2 and 2.5 tons, we prefer to study the windows, the insulation and the air distribution rather than decide by eye.\u003c\/p\u003e\n\n\u003ch3\u003eThe furnace keeps its role\u003c\/h3\u003e\n\u003cp\u003eIn an \"add-on\" setup, the furnace keeps its blower, its filters and its role as backup heat. In summer, the coil cools the air passing through it. In winter, with a heat pump, it releases the heat captured outdoors. In very cold weather, the furnace takes over at a threshold that we adjust with you.\u003c\/p\u003e\n\u003cp\u003eThis combination avoids redoing the ducts and leaves the house in its original state.\u003c\/p\u003e\n\n\u003ch3\u003eA medium-sized house, in practice\u003c\/h3\u003e\n\u003cp\u003eThink of the two-storey cottage whose furnace serves the kitchen and the bedrooms alike, the extended bungalow or the two-generation home whose living room is sunny all afternoon. What these homes have in common is a cooling load higher than a compact unit, without requiring the largest size in the series.\u003c\/p\u003e\n\u003cp\u003eIn these homes, two things matter more than floor area: windows facing south or west and the state of the roof insulation. A poorly insulated attic can by itself push up the air conditioning bill; we always look at it during the visit, and we point it out if a simple improvement can reduce the load.\u003c\/p\u003e\n\n\u003ch3\u003eThe shoulder season, between furnace and heat pump\u003c\/h3\u003e\n\u003cp\u003eAnother advantage of the add-on heat pump: in the shoulder season, in spring and fall, the unit can provide mild heating on its own, without turning on the furnace. The coldest months remain the domain of the backup heat, which then takes over. You move from one mode to the other without thinking about it, since the thermostat controls the whole system.\u003c\/p\u003e\n\u003cp\u003eIf you go away on a trip, you can set an economy temperature, as with any central system. The return to normal temperature happens gradually.\u003c\/p\u003e\n\n\u003ch3\u003eBasic maintenance\u003c\/h3\u003e\n\u003cp\u003eA clean coil works better. Replace the filter at regular intervals, keep the condensate drain clear, and keep the area around the outdoor unit free of leaves and snow. We show you where these points are at start-up; do not hesitate to ask us questions after the installation.\u003c\/p\u003e\n\n\u003ch3\u003eThe installation at your home\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, holder of RBQ licence 5645-9605-01. For this coil, here is our sequence:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, examining the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum, with an insulated transition built as needed, and sealing the air connections;\u003c\/li\u003e\n\u003cli\u003einstalling the outdoor unit on a stand, brazing, nitrogen test and vacuum pull;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003estart-up, airflow adjustment and a demonstration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat the warranty covers\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer offers a 10-year limited warranty on parts if registration is done within 90 days of installation; without registration, the period is 5 years. We handle this formality with you.\u003c\/p\u003e\n\n\u003ch3\u003eBefore you buy, check this\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-454B calls for an outdoor unit using the same refrigerant, installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe advertised ratings apply to the certified system, not to the coil alone.\u003c\/li\u003e\n\u003cli\u003eThe blower must move the required airflow; the furnace must be narrow enough for this cabinet, or we build the transition.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this coil heat?\u003c\/strong\u003e Yes, with a heat pump. With a central air conditioner, it is limited to cooling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan my current air conditioner stay?\u003c\/strong\u003e Generally not: R-454B requires the unit specified by the manufacturer, and we install the complete system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy furnace has a different width. What should I do?\u003c\/strong\u003e We measure it and, if needed, build an insulated transition on site.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert subsidy\u003c\/h3\u003e\n\u003cp\u003eThe paired Comfortmaker system is on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We check the official list when we prepare your quote and put the application together with you.\u003c\/p\u003e\n\n\u003ch3\u003eGet your project estimated\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for our free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is offered to spread out the cost of the work.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402721095972,"sku":"EAM5X30M14A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EAM5X_EAM5X30M14A_00_2_5_TONNES_30000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765771","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-eam5x30m14a-a-2-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}