{"product_id":"serpentin-devaporateur-comfortmaker-eam5x37m21a-a-3-tonnes","title":"COMFORTMAKER EAM5X37M21A Evaporator A-Coil | 3 Tons","description":"\u003ch2\u003eEAM5X37M21A: the smallest coil in the series, made for the electrically heated bungalow\u003c\/h2\u003e\n\u003cp\u003eAcross Greater Montreal, thousands of bungalows and townhouses still have the electric furnace they got in the seventies or eighties, with old baseboard heaters or window air conditioners for the summer. The \u003cstrong\u003eComfortmaker EAM5X37M21A evaporator coil\u003c\/strong\u003e is made for that kind of home. It is a cased A-coil rated at \u003cstrong\u003e3 tons\u003c\/strong\u003e (36,000 BTU\/h nominal), \u003cstrong\u003e21 in\u003c\/strong\u003e wide, and it runs on \u003cstrong\u003eR-454B refrigerant\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eAirGreen installs it in Montreal, Laval, Longueuil, the North Shore and the South Shore. This page explains what the model does, which outdoor unit it works with, what you should measure at home before buying, and how it differs from the seven other coils in the EAM5X range.\u003c\/p\u003e\n\n\u003ch3\u003eWhat an evaporator coil actually does\u003c\/h3\u003e\n\u003cp\u003eThink of it as the heat exchanger on the indoor side. It sits in the furnace plenum, right in the path of the air. When the outdoor unit sends cold refrigerant through its tubes, the house air passing through loses its heat and a good share of its moisture. The water that condenses runs into the pan and then to the drain.\u003c\/p\u003e\n\u003cp\u003eWith a heat pump outside, the cycle reverses in winter. The coil becomes the surface that releases the heat collected outdoors. The same equipment therefore works in both seasons, and the air distribution in your home, meaning your existing ductwork, stays the same.\u003c\/p\u003e\n\n\u003ch3\u003eA 3-ton size for small and medium-sized homes\u003c\/h3\u003e\n\u003cp\u003eThe 3-ton size is the most modest in the series. It suits a home with reasonably sized rooms and walls that have been insulated over the years of renovations. We never pick the capacity by eye: a visit to your home, a calculation of the house's needs and a look at your electricity bill guide the decision. An oversized coil does not make the house more comfortable. It cools quickly, shuts off quickly and dehumidifies poorly.\u003c\/p\u003e\n\u003cp\u003eIf the calculation points to a larger capacity, the range offers models of 3.5 tons, 4 tons and 5 tons. The comparison section below summarizes the differences.\u003c\/p\u003e\n\n\u003ch3\u003eThe certified match: three published outdoor units\u003c\/h3\u003e\n\u003cp\u003eA coil on its own has no efficiency rating. Complete systems are what get certified, with an AHRI number that ties one coil to one specific outdoor unit. Here are the three published matches for the EAM5X37M21A:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eQ5H9V24*K*AAA\u003c\/strong\u003e: AHRI 217953748, SEER2 16.0 and HSPF2 9.5, with 23,000 BTU\/h in cooling and 24,800 BTU\/h in heating at 47 °F;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eN5H9V24*K*AAA\u003c\/strong\u003e: AHRI 217953741, same ratings and same capacities as the previous one;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eC5H8T24*K*AAA\u003c\/strong\u003e: AHRI 216364458, SEER2 15.5 and HSPF2 7.8, with 22,400 BTU\/h in cooling and 24,600 BTU\/h in heating at 47 °F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe AHRI number is the item to compare from one quote to the next. Two contractors who talk about a \"3-ton system\" are not necessarily selling the same thing, while the number leaves no ambiguity.\u003c\/p\u003e\n\n\u003ch3\u003eTurning an electric furnace into an \"add-on\" heat pump\u003c\/h3\u003e\n\u003cp\u003eThis is the most common scenario with this model. We keep the furnace, its blower and its filters, then add the coil above it and an outdoor unit in the yard. In summer, the house is air conditioned. In winter, the heat pump supplies most of the heat, and the furnace only starts below an outdoor temperature threshold that we set with you.\u003c\/p\u003e\n\u003cp\u003eAn electric furnace converts each kilowatt-hour into an equivalent amount of heat. A heat pump moves heat instead of making it, which is why the bill goes down when a home switches to this type of system. The colder it gets outside, the more the gap narrows, and that is why the furnace stays useful for the coldest days.\u003c\/p\u003e\n\n\u003ch3\u003eDimensions, weight and connections: what we check on site\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ecabinet 21 in wide by 29-3\/4 in high, net weight 79.4 lb;\u003c\/li\u003e\n\u003cli\u003e3\/4 in suction connection, the smallest in the series;\u003c\/li\u003e\n\u003cli\u003epossible positions: upflow, downflow or horizontal;\u003c\/li\u003e\n\u003cli\u003etwo condensate pans in fibreglass-reinforced thermoset polyester, one for vertical installation and one for horizontal installation, both sloped toward the drain;\u003c\/li\u003e\n\u003cli\u003eTXV metering device, which doses the refrigerant according to the load;\u003c\/li\u003e\n\u003cli\u003efactory-mounted A2L leak sensor and harness, with the dissipation board, enclosure and power harness supplied in the parts box.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 21 in width must match that of your furnace. If it does not, we build an insulated transition on site rather than force a compromise.\u003c\/p\u003e\n\n\u003ch3\u003eChoosing between the EAM5X37M21A and its seven neighbours\u003c\/h3\u003e\n\u003cp\u003eThe range has eight coils from the same family, all on R-454B, all with a TXV metering device and a cabinet. The differences that matter for your decision:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eEAM5X42M21A and EAM5X43M21A\u003c\/strong\u003e: 3.5 tons, same 21 in width, matched with the B5H3V36*K*AAA unit. One step up in capacity, without changing the furnace.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAM5X42M24A\u003c\/strong\u003e: 3.5 tons in a 24-1\/2 in cabinet, for a wider furnace.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAM5X48M21A and EAM5X48M24A\u003c\/strong\u003e: 4 tons, in 21 in or 24-1\/2 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAM5X60M24A and EAM5X61M21A\u003c\/strong\u003e: 5 tons, in 24-1\/2 in or 21 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe EAM5X37M21A is therefore the logical choice when the furnace measures 21 in and the load calculation stays in the modest range. It is also the only one in this family with a 3\/4 in suction connection.\u003c\/p\u003e\n\n\u003ch3\u003eWhat this coil does not do\u003c\/h3\u003e\n\u003cp\u003eIt does not pair with just any old air conditioner. It runs on R-454B and must be installed, at the same time, with an outdoor unit designed for the same refrigerant. Keeping the old outdoor unit is therefore generally not possible. Nor does it improve airflow on its own: the furnace blower must already be able to move the air the system requires.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan it heat?\u003c\/strong\u003e Yes, if it is connected to a heat pump. With a central air conditioner, it only provides cooling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill my furnace still be used?\u003c\/strong\u003e Yes. It provides backup heat at the lowest temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the width is different?\u003c\/strong\u003e We measure and build an insulated transition if needed.\u003c\/p\u003e\n\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is carried out under RBQ licence 5645-9605-01. For this coil, the typical process is as follows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace and checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum and sealing the connections;\u003c\/li\u003e\n\u003cli\u003esetting up the outdoor unit, brazing the piping, nitrogen leak test and vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003estart-up, airflow adjustment, then an explanation of how the system works, in your home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert rebate\u003c\/h3\u003e\n\u003cp\u003eThe matched Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. Eligibility is judged on the complete system and not on the coil alone, and the amount depends on the installation date and your situation. We check the official list at the time of the quote and put the file together with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402708709668,"sku":"EAM5X37M21A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EAM5X_EAM5X37M21A_00_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765771","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-eam5x37m21a-a-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}