{"product_id":"serpentin-devaporateur-comfortmaker-eam5x42m24a-a-3-5-tonnes","title":"COMFORTMAKER EAM5X42M24A Evaporator A-Coil | 3.5 Tons","description":"\u003ch2\u003eComfortmaker EAM5X42M24A: the 3.5-ton coil for wide 24-1\/2 in furnaces\u003c\/h2\u003e\n\u003cp\u003eNot all furnaces look alike. Some have a narrow cabinet, while others, newer or sturdier, measure 24-1\/2 in wide. If yours belongs to the second category and your home needs a \u003cstrong\u003e3.5-ton\u003c\/strong\u003e system (42,000 BTU\/h nominal), the \u003cstrong\u003eComfortmaker EAM5X42M24A evaporator coil\u003c\/strong\u003e is designed to fit on it without improvising.\u003c\/p\u003e\n\u003cp\u003eIt is a cased A-coil on \u003cstrong\u003eR-454B refrigerant\u003c\/strong\u003e that fits the plenum of a furnace or blower cabinet. AirGreen installs it in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eWhy width matters so much\u003c\/h3\u003e\n\u003cp\u003eThe coil slides into the plenum, above the furnace. If its width does not match the cabinet, a transition piece has to be built, which adds time and more joints to seal. With a 24-1\/2 in cabinet on a furnace of the same size, the transition is direct: the air crosses the whole surface of the coil, with no detour, and the seal relies on a simpler assembly.\u003c\/p\u003e\n\u003cp\u003eThe flip side: if your furnace is narrower, this model is not the right one. In that case, the EAM5X42M21A offers the same capacity in 21 in.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the data sheet says\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal capacity: 3.5 tons, or 42,000 BTU\/h.\u003c\/li\u003e\n\u003cli\u003eCabinet: 24-1\/2 in wide by 29-3\/4 in high.\u003c\/li\u003e\n\u003cli\u003eNet weight: 76.3 lb.\u003c\/li\u003e\n\u003cli\u003eSuction connection: 7\/8 in.\u003c\/li\u003e\n\u003cli\u003eMetering device: TXV.\u003c\/li\u003e\n\u003cli\u003ePositions: upflow, downflow or horizontal.\u003c\/li\u003e\n\u003cli\u003eSloped condensate pans in fibreglass-reinforced thermoset polyester, one for each orientation.\u003c\/li\u003e\n\u003cli\u003eSafety: factory-installed A2L leak sensor and harness, with the rest of the detection hardware supplied in the parts box.\u003c\/li\u003e\n\u003cli\u003eManufacturer parts warranty: ten years with registration within 90 days of installation, five years without registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAnd the outdoor unit?\u003c\/h3\u003e\n\u003cp\u003eFor this model, the coil connects to a Comfortmaker outdoor unit of the same capacity, always on R-454B. In the ENERGY STAR match lists we consulted, none appears for the EAM5X42M24A. That does not mean it is unusable: it means that, before ordering, we confirm which combination is offered and which AHRI number goes with it.\u003c\/p\u003e\n\u003cp\u003eIf certified efficiency or a rebate weighs heavily in your decision, this is a point to settle first. In the same spirit, a system matched to a 21 in coil, such as the EAM5X42M21A, has published matches that are easier to read.\u003c\/p\u003e\n\n\u003ch3\u003eCooling without changing the ducts\u003c\/h3\u003e\n\u003cp\u003eThe main appeal of this coil is that it makes use of the existing air distribution. A single outdoor unit replaces the window air conditioners, one thermostat controls everything, and cool air circulates to every room through the same vents. The condensation is collected in the pan and carried to the drain, which dries the air during humid periods.\u003c\/p\u003e\n\n\u003ch3\u003eAnd heating, with a heat pump\u003c\/h3\u003e\n\u003cp\u003eIf the outdoor unit is a heat pump, the coil also works in winter. The system supplies most of the heat as long as the cold remains manageable for it; the furnace starts beyond a temperature threshold that we set together. The energy bill benefits from this sharing of the work. With an air conditioner alone, the furnace keeps heating as before.\u003c\/p\u003e\n\n\u003ch3\u003eA common scenario on the North Shore\u003c\/h3\u003e\n\u003cp\u003eA North Shore house built in the nineties, with a wide furnace in the basement and a central air conditioner that has had its day. The owner does not want to touch the floor or open up new walls. The 24-1\/2 in coil goes on the existing furnace, the outdoor unit replaces the old one in the yard, and the house keeps its air vents and its thermostat in a familiar spot.\u003c\/p\u003e\n\u003cp\u003eIn Montreal, in a duplex or triplex where each unit has its own furnace, the reasoning is the same, but the plenum is sometimes tighter: the height available above the furnace must be measured carefully before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eHeight and clearance: do not forget them\u003c\/h3\u003e\n\u003cp\u003eThe cabinet is 29-3\/4 in high. In a basement with a low ceiling, that dimension adds to the height of the furnace and can decide everything. We measure the clearance up to the joists, check access for servicing the filter and the pan, then confirm the installation position, upflow, downflow or horizontal, according to the layout of the mechanical room.\u003c\/p\u003e\n\n\u003ch3\u003eUpkeep after installation\u003c\/h3\u003e\n\u003cp\u003eAn air conditioning system lasts longer when you look after it: clean filter, clear drain, outdoor unit free of leaves and snow. We show you where the points to watch are and how often to check the filter. The coil's sloped pan is designed to drain water, but a blocked drain remains the most ordinary cause of water damage; better to know that before summer.\u003c\/p\u003e\n\n\u003ch3\u003eHow this model compares with the rest of the series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSame capacity, narrower: \u003cstrong\u003eEAM5X42M21A\u003c\/strong\u003e and \u003cstrong\u003eEAM5X43M21A\u003c\/strong\u003e, in 21 in, with the published B5H3V36*K*AAA unit.\u003c\/li\u003e\n\u003cli\u003eSame width, higher capacity: \u003cstrong\u003eEAM5X48M24A\u003c\/strong\u003e, 4 tons.\u003c\/li\u003e\n\u003cli\u003eLower capacity: \u003cstrong\u003eEAM5X37M21A\u003c\/strong\u003e, 3 tons in 21 in.\u003c\/li\u003e\n\u003cli\u003eHigher capacity: \u003cstrong\u003eEAM5X60M24A\u003c\/strong\u003e, 5 tons in 24-1\/2 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe EAM5X42M24A is the only one in the range to combine 3.5 tons and a 24-1\/2 in width.\u003c\/p\u003e\n\n\u003ch3\u003eHow we work\u003c\/h3\u003e\n\u003cp\u003eWe start by measuring the furnace, assessing the blower and inspecting the electrical panel. The coil is installed in the plenum and its connections are sealed. The outdoor unit goes on a pad or a bracket; the piping is brazed, tested with nitrogen and then put under vacuum. Finally, we connect the drain and the thermostat, adjust the airflow and go over how the system works with you. AirGreen, a Montreal heating and cooling company founded more than fifteen years ago, carries out this work under RBQ licence 5645-9605-01.\u003c\/p\u003e\n\n\u003ch3\u003eQuestions to ask before signing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWhat AHRI number appears on the quote, for the complete system?\u003c\/li\u003e\n\u003cli\u003eDoes the width of the furnace match 24-1\/2 in?\u003c\/li\u003e\n\u003cli\u003eDoes the blower deliver the required airflow?\u003c\/li\u003e\n\u003cli\u003eIs the outdoor unit designed for R-454B?\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert rebate\u003c\/h3\u003e\n\u003cp\u003eThe matched Comfortmaker system must appear on Hydro-Québec's list of eligible heat pumps to qualify for the incentive. The amount depends on the installation date and your situation. We check the official list at the quote stage and prepare the application with you, with no surprises.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402710249764,"sku":"EAM5X42M24A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EAM5X_EAM5X42M24A_00_3_5_TONNES_42000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765772","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-eam5x42m24a-a-3-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}