{"product_id":"serpentin-devaporateur-comfortmaker-eam5x48m21a-a-4-tonnes","title":"COMFORTMAKER EAM5X48M21A Evaporator A-Coil | 4 Tons","description":"\u003ch2\u003eEAM5X48M21A coil: 4 tons of capacity in a 21 in cabinet, for the large home with a furnace\u003c\/h2\u003e\n\u003cp\u003eIn some homes, winter is won or lost in the basement: a gas or electric furnace working hard from November to March, many rooms, one more storey than average. For these homes, switching to a heat pump while keeping the furnace as backup is a sensible way to reduce reliance on baseline heating. The \u003cstrong\u003eComfortmaker EAM5X48M21A\u003c\/strong\u003e is the coil that makes this setup possible in a \u003cstrong\u003e21 in\u003c\/strong\u003e cabinet.\u003c\/p\u003e\n\u003cp\u003eIt is a cased A-coil of \u003cstrong\u003e4 tons\u003c\/strong\u003e (48,000 BTU\/h nominal), running on \u003cstrong\u003eR-454B\u003c\/strong\u003e. We install it in homes in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eThinking about capacity starting from winter\u003c\/h3\u003e\n\u003cp\u003eIn Quebec, a heat pump is judged on its heating capacity as much as on its cooling capacity. The two published matches for this coil show 43,500 BTU\/h in cooling and 49,000 BTU\/h in heating at 47 °F. This gap in favour of heating is useful in a large home: it extends the part of the cold season in which the heat pump is enough on its own.\u003c\/p\u003e\n\u003cp\u003eBeyond that, the furnace takes over. That is the principle of the \"add-on\" setup: a heat pump that handles the mild and moderate days, a furnace that holds the cold nights, and a switchover threshold set with you so that the transition goes unnoticed.\u003c\/p\u003e\n\n\u003ch3\u003eThe two certified matches\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eQ5H9V48*K*AAA\u003c\/strong\u003e: AHRI 217954402, SEER2 15.2, HSPF2 9.0;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eN5H9V48*K*AAA\u003c\/strong\u003e: AHRI 217954397, SEER2 15.2, HSPF2 9.0.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe published capacities are identical for both. The choice between the two is therefore made on the location of the outdoor unit, availability and your installer's preference, more than on the advertised performance.\u003c\/p\u003e\n\n\u003ch3\u003eThe 21 in cabinet and its companions\u003c\/h3\u003e\n\u003cp\u003eA cabinet 21 in wide and 29-3\/4 in high, weighing 77.2 lb net, is a reasonable size for a coil of this capacity. Its suction connection is 7\/8 in. It accepts upflow, downflow or horizontal installation, and it is equipped with two sloped pans in fibreglass-reinforced polyester so that the condensation water drains equally well in either direction.\u003c\/p\u003e\n\u003cp\u003eThe metering device is a TXV. The A2L leak sensor and its harness are factory-mounted; the rest of the detection kit, that is, the dissipation board, the enclosure and the power harness, ships separately and is connected during installation.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if my furnace is wider?\u003c\/h3\u003e\n\u003cp\u003eIf your cabinet measures 24-1\/2 in, the same capacity exists under the code EAM5X48M24A. We measure before ordering, and when the difference is small, an insulated transition built on site settles the matter without changing the model.\u003c\/p\u003e\n\n\u003ch3\u003e4 tons or something else? Reference points in the range\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eEAM5X37M21A\u003c\/strong\u003e: 3 tons, 21 in, for a more modest home.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAM5X42M21A\u003c\/strong\u003e and \u003cstrong\u003eEAM5X43M21A\u003c\/strong\u003e: 3.5 tons, 21 in, with the B5H3V36*K*AAA unit.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAM5X42M24A\u003c\/strong\u003e: 3.5 tons, 24-1\/2 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAM5X48M24A\u003c\/strong\u003e: 4 tons, 24-1\/2 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAM5X60M24A\u003c\/strong\u003e and \u003cstrong\u003eEAM5X61M21A\u003c\/strong\u003e: 5 tons, with the same Q5H9V48*K*AAA outdoor unit as this model.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHere is an interesting point: the 4-ton and the 5-ton share the same family of outdoor units. The final capacity therefore depends in part on the coil chosen, which is one more reason to have the load calculation validated before placing the order.\u003c\/p\u003e\n\n\u003ch3\u003eWhat to keep in mind before signing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil has no efficiency rating of its own; ratings belong to the system.\u003c\/li\u003e\n\u003cli\u003eIt requires an R-454B outdoor unit, installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe furnace blower must deliver the system's airflow; a 4-ton calls for good airflow.\u003c\/li\u003e\n\u003cli\u003eThe existing ducts must be able to carry that air without excessive noise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA typical January day, step by step\u003c\/h3\u003e\n\u003cp\u003eIn the morning, it is mild for the season and the heat pump is enough: the furnace stays off, and the blower circulates the air warmed by the coil. In the afternoon, the wind picks up and the outdoor temperature drops. The system keeps running as long as it stays above the threshold we programmed. At night, when the cold becomes severe, the furnace kicks in as well, without anyone having to touch the thermostat.\u003c\/p\u003e\n\u003cp\u003eThis automatic sharing is the real comfort of this setup: you do not choose between two appliances, the thermostat takes care of it.\u003c\/p\u003e\n\n\u003cp\u003eFor North Shore homeowners, where the temperature swings between day and night are often marked in spring and fall, this automatic management also avoids heating needlessly with the backup when a heat pump would be enough.\u003c\/p\u003e\n\n\u003ch3\u003eAirflow, a detail that matters with 4 tons\u003c\/h3\u003e\n\u003cp\u003eThe greater the capacity, the greater the amount of air that has to pass through the coil. If the ducts are narrow, if the return air is pinched or if the filter is too restrictive, the blower struggles, the noise increases and the heat exchange suffers. That is why we inspect the return, the main branches and the filter during the visit. In a Laval or Longueuil house built at a time when little air conditioning was installed, we sometimes recommend a simple adjustment of the grilles or a more suitable filter.\u003c\/p\u003e\n\u003cp\u003eThese checks are not a luxury: they determine whether the system will deliver the comfort shown on the data sheet.\u003c\/p\u003e\n\n\u003ch3\u003eThe manufacturer's warranty\u003c\/h3\u003e\n\u003cp\u003eOn parts, Comfortmaker grants a limited ten-year warranty when the unit is registered within 90 days of installation. Without registration, the coverage is five years. We do the registration for you.\u003c\/p\u003e\n\n\u003ch3\u003eHow the installation unfolds\u003c\/h3\u003e\n\u003cp\u003eThe visit begins with measuring the furnace and checking the electrical service. Then come installing the coil in the plenum, sealing the connections, setting up the outdoor unit, brazing the piping, the nitrogen test, the vacuum, connecting the drain and the thermostat, then adjusting the airflow. AirGreen is a family-owned heating and cooling company, based in Montreal for more than fifteen years, working under RBQ licence 5645-9605-01.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert rebate\u003c\/h3\u003e\n\u003cp\u003eThe matched Comfortmaker system is on Hydro-Québec's list of eligible heat pumps. The amount varies according to the installation date and your situation. We check it on the official list at the quote and prepare the application with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402714181924,"sku":"EAM5X48M21A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EAM5X_EAM5X48M21A_00_4_TONNES_48000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765772","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-eam5x48m21a-a-4-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}