{"product_id":"serpentin-devaporateur-comfortmaker-esh5x24m12a-horizontal-2-tonnes","title":"COMFORTMAKER ESH5X24M12A Horizontal Evaporator Coil | 2 Tons","description":"\u003ch2\u003eESH5X24M12A: the 2-ton Comfortmaker evaporator coil for a small home with a horizontal furnace\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eComfortmaker ESH5X24M12A evaporator coil\u003c\/strong\u003e is the smallest size in the ESH5X range. It is meant for the compact home that already has a furnace and wants to add central air conditioning, or even heat pump heating. It is a cased coil, runs on \u003cstrong\u003eR-454B\u003c\/strong\u003e and has a nominal rating of 24,000 BTU\/h. We install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eA July day in a compact bungalow\u003c\/h3\u003e\n\u003cp\u003ePicture a bungalow or the ground floor of a plex: windows facing south, a furnace in one corner of the basement, a thermostat in the hallway. At three in the afternoon, hot, sticky air enters the return. It passes through the coil, gives up its heat to the refrigerant, loses its moisture as water, then comes out cool at the vents in every room.\u003c\/p\u003e\n\u003cp\u003eThat is exactly what this model does. It does not make the cold by itself: it is the indoor heat-exchange surface of a circuit whose other half sits outside, in the outdoor unit.\u003c\/p\u003e\n\n\u003ch3\u003eWhat \"2 tons\" means, without the jargon\u003c\/h3\u003e\n\u003cp\u003eThe nominal size of 2 tons equals 24,000 BTU\/h. It is a sizing reference, not a promise of output. Actual capacity depends on the match you choose: with the B5H3V24*K*AAA outdoor unit, the system data sheet lists 22,200 BTU\/h of cooling. We like to put that figure on the table at the first visit, because it avoids unpleasant surprises.\u003c\/p\u003e\n\u003cp\u003eIn a small home, an oversized unit runs in short bursts. The air cools quickly, but the humidity stays. A modest size, properly calculated, runs longer at a time and dries the air better.\u003c\/p\u003e\n\n\u003ch3\u003eTwo published matches, two approaches\u003c\/h3\u003e\n\u003cp\u003eComfortmaker publishes two certified systems for the ESH5X24M12A. Here they are side by side:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eB5H3V24*K*AAA\u003c\/strong\u003e, AHRI number 218406843: cooling 22,200 BTU\/h, heating 25,800 BTU\/h at 47 °F, SEER2 19.0, HSPF2 9.5;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eC5H8T24*K*AAA\u003c\/strong\u003e, AHRI number 216367355: cooling 22,600 BTU\/h, heating 24,600 BTU\/h at 47 °F, SEER2 16.0, HSPF2 7.8;\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe first belongs to the SoftSound family, the second to the Mainline family. The first one has higher ratings; the second can suit you better when budget weighs more heavily. We show you both on paper and let you decide with the facts in hand.\u003c\/p\u003e\n\n\u003ch3\u003eWhy the coil has no efficiency rating\u003c\/h3\u003e\n\u003cp\u003eSEER2 and HSPF2 ratings describe an entire system: one specific coil and one specific outdoor unit, linked by an AHRI number. On its own, the indoor part has nothing to display. When two quotes contradict each other, always compare the AHRI numbers before comparing prices.\u003c\/p\u003e\n\u003cp\u003eComfortmaker also states that its ENERGY STAR matches with the SoftSound 20 \/ 23 (B5H0V, B5H3V) and Mainline 18 (C5H8T) heat pumps all use R-454B, with ratings published when paired with a furnace and a wall control (\"+WALLCON\").\u003c\/p\u003e\n\n\u003ch3\u003eWhat you gain by choosing a small size\u003c\/h3\u003e\n\u003cp\u003eA 2-ton coil raises fewer questions at installation: the transition is easier to fit, the drain run is short, and the job usually goes ahead without surprises. In a plex unit, where mechanical space is tight, you notice that advantage from the first day.\u003c\/p\u003e\n\u003cp\u003eOn the comfort side, the difference shows mostly in the shoulder seasons. When the heat is moderate, a well-proportioned system runs smoothly, keeps rooms at an even temperature and avoids the noise of repeated starts. Occupants often describe a home that feels \"less sticky\" rather than \"icy\", and that is exactly the goal.\u003c\/p\u003e\n\n\u003ch3\u003eHorizontal form: where this coil fits\u003c\/h3\u003e\n\u003cp\u003eThis model is designed for a furnace lying on its side: crawl space, attic, basement ceiling. The manufacturer publishes a horizontal position with bidirectional airflow, which gives some flexibility depending on the direction of air movement in your installation. Under the coil, a sloped, corrosion-resistant drain pan collects the condensation; its diameter is not published, so we check it on site.\u003c\/p\u003e\n\u003cp\u003eThe metering device is a TXV. It doses the refrigerant according to the coil's actual demand, so the exchanger is not fed blindly.\u003c\/p\u003e\n\n\u003ch3\u003eChoosing between the ESH5X24M12A and its siblings in the series\u003c\/h3\u003e\n\u003cp\u003eThe whole ESH5X series uses R-454B, with a TXV and a cased design. What changes from one model to the next is the size and the matching outdoor unit.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eESH5X24M12A\u003c\/strong\u003e (2 tons): B5H3V24*K*AAA outdoor unit, the smallest size;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eESH5X30M12A\u003c\/strong\u003e (2.5 tons): same B5H3V24*K*AAA unit, one step up;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eESH5X36M12A\u003c\/strong\u003e (3 tons) and \u003cstrong\u003eESH5X42M12A\u003c\/strong\u003e (3.5 tons): B5H0V36*K*AAA unit;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eESH5X48M12A\u003c\/strong\u003e (4 tons) and \u003cstrong\u003eESH5X60M12A\u003c\/strong\u003e (5 tons): B5H0V48*K*AAA unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf your home is small and well insulated, the 2-ton is the natural starting point. If the visit reveals large windows or a poorly insulated upper floor, we will look at the 2.5-ton, which shares the same outdoor unit.\u003c\/p\u003e\n\n\u003ch3\u003eThe furnace's role in an \"add-on\" system\u003c\/h3\u003e\n\u003cp\u003eIn this setup, the furnace keeps its blower, its filters and its heating elements. The coil goes into the plenum, in the path of the air. In summer, the refrigerant evaporates in its tubes and picks up heat from the room. In winter, with a heat pump, the cycle reverses and the heat captured outside is delivered into the home.\u003c\/p\u003e\n\u003cp\u003eThe furnace then serves as backup: it takes over when the outdoor temperature drops below the threshold we set with you. It is a good scenario for turning an electric furnace into a central heat pump without redoing the ductwork.\u003c\/p\u003e\n\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, and our work is done under RBQ licence 5645-9605-01. For this coil and its outdoor unit, the job includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, and checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstallation in the plenum, with an insulated transition built on site if the width does not match, and sealing of the connections;\u003c\/li\u003e\n\u003cli\u003ethe outdoor unit on a pad or bracket, brazed piping, a nitrogen leak test and evacuation;\u003c\/li\u003e\n\u003cli\u003econnection of the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and a clear explanation of how everything works.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat to check before you buy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-454B requires an outdoor unit using the same refrigerant, installed at the same time: you do not keep an old air conditioner.\u003c\/li\u003e\n\u003cli\u003eThe furnace width is measured before the order is placed.\u003c\/li\u003e\n\u003cli\u003eThe blower must be able to deliver the airflow the system requires.\u003c\/li\u003e\n\u003cli\u003eThe home's load is calculated to confirm that 2 tons is enough.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWarranty and safety\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer offers a 10-year limited parts warranty if the unit is registered within 90 days of installation; without registration, coverage is 5 years. We take care of the registration for you. A refrigerant leak dissipation system is factory-installed, according to the Comfortmaker page.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert grant\u003c\/h3\u003e\n\u003cp\u003eThe matched Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation: we check it against the official list when we prepare your quote and we put the application together with you. Eligibility applies to the complete system, never to the coil alone.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402711658788,"sku":"ESH5X24M12A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_ESH5X_ESH5X24M12A_00_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765769","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-esh5x24m12a-horizontal-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}