{"product_id":"serpentin-devaporateur-comfortmaker-esh5x30m12a-horizontal-2-5-tonnes","title":"COMFORTMAKER ESH5X30M12A Horizontal Evaporator Coil | 2.5 Tons","description":"\u003ch2\u003eThe ESH5X30M12A, a 2.5-ton Comfortmaker coil that bridges the gap between small and medium\u003c\/h2\u003e\n\u003cp\u003eBetween a home that gets by with 2 tons and another that needs 3, there are a lot of Greater Montreal homes: suburban two-storeys, enlarged bungalows, renovated semi-detached houses. The \u003cstrong\u003eComfortmaker ESH5X30M12A evaporator coil\u003c\/strong\u003e was designed for them. It is a 2.5-ton cased coil (30,000 BTU\/h nominal), running on \u003cstrong\u003eR-454B refrigerant\u003c\/strong\u003e, that installs on a furnace or a blower cabinet. Our crews work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhy a half size exists\u003c\/h3\u003e\n\u003cp\u003eCentral sizes advance in half-ton steps. That may seem minor, but in a home right at the limit, that step makes the difference between a system that follows demand and one that struggles or shuts off too soon. The ESH5X30M12A exists for cases where the calculated load falls in that in-between.\u003c\/p\u003e\n\u003cp\u003eOur method is simple: we calculate the home's load, we look at the existing furnace, then we choose the size. Never the other way around.\u003c\/p\u003e\n\n\u003ch3\u003eThe base match: B5H3V24*K*AAA\u003c\/h3\u003e\n\u003cp\u003eAn interesting fact: this 2.5-ton coil shares its main outdoor unit with the 2-ton model, the B5H3V24*K*AAA. It is the coil that changes, not the unit outside, and the published ratings change slightly with it. Comfortmaker lists two certified systems:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eB5H3V24*K*AAA\u003c\/strong\u003e outdoor unit, AHRI 218406955, cooling 22,400 BTU\/h, heating 25,600 BTU\/h at 47 °F, SEER2 19.5, HSPF2 9.5;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eC5H8T24*K*AAA\u003c\/strong\u003e outdoor unit, AHRI 216368117, cooling 23,200 BTU\/h, heating 25,200 BTU\/h at 47 °F, SEER2 16.5, HSPF2 7.8;\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eKeep in mind that the AHRI number belongs to the coil-plus-unit pair. It is used to compare two quotes and to validate a grant application.\u003c\/p\u003e\n\n\u003ch3\u003eFour seasons with this coil\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSpring.\u003c\/strong\u003e The first mild days: the system heats or cools without the furnace waking up. This is the period when a heat pump shines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSummer.\u003c\/strong\u003e The coil captures heat and moisture from the air passing through it; the condensation runs off through the sloped pan to the drain.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFall.\u003c\/strong\u003e The same logic as spring, with the bonus of mild heating from the heat pump coming back.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWinter.\u003c\/strong\u003e When the outdoor temperature falls below the threshold we set with you, the furnace takes over as backup. You keep the comfort of the deep cold, without abandoning what already works in your home.\u003c\/p\u003e\n\n\u003ch3\u003eHow this model compares with the others in the ESH5X series\u003c\/h3\u003e\n\u003cp\u003eAll models in the series are horizontal and cased, with a TXV and R-454B. Here is what sets them apart in practice:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eESH5X24M12A\u003c\/strong\u003e, 2 tons: same B5H3V24*K*AAA outdoor unit, better suited to the smallest homes;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eESH5X30M12A\u003c\/strong\u003e, 2.5 tons: the model we are discussing here;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eESH5X36M12A\u003c\/strong\u003e, 3 tons: moves to the B5H0V36*K*AAA unit;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eESH5X42M12A\u003c\/strong\u003e, 3.5 tons: same B5H0V36*K*AAA unit as the 3-ton;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eESH5X48M12A\u003c\/strong\u003e, 4 tons, and \u003cstrong\u003eESH5X60M12A\u003c\/strong\u003e, 5 tons: B5H0V48*K*AAA unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf you are torn between the 2-ton and this one, the calculated load decides. If you are torn between this one and the 3-ton, we also look at the furnace and the blower, because the outdoor unit changes at that point.\u003c\/p\u003e\n\n\u003ch3\u003eA horizontal, bidirectional form\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer publishes a horizontal position with bidirectional airflow. In practice, this coil fits in a crawl space, an attic or a basement ceiling, wherever the furnace lies on its side. The sloped, corrosion-resistant drain pan sits under the exchanger; the drain diameter is not published, so we check it at the visit.\u003c\/p\u003e\n\u003cp\u003eThe TXV metering device adjusts the refrigerant flow to the load. The manufacturer also provides a factory-installed refrigerant leak dissipation system, noted on its page.\u003c\/p\u003e\n\n\u003ch3\u003eWhat to know about R-454B\u003c\/h3\u003e\n\u003cp\u003eThis refrigerant requires a consistent match: the coil and the outdoor unit are installed together, with the same fluid. It is therefore generally not possible to keep an old air conditioner and connect this coil to it. We install the complete system, from the brazed piping to commissioning.\u003c\/p\u003e\n\n\u003ch3\u003eThree ways to tell whether 2.5 tons suits you\u003c\/h3\u003e\n\u003cp\u003eFirst clue: your old air conditioner, if there was one, always seemed a little tight in the middle of a heat wave, but never truly overwhelmed. Second clue: some rooms, often upstairs or on the south side, stay warmer than the rest. Third clue: the house has been enlarged or better insulated since the original installation, which shifts the load without anyone thinking about it.\u003c\/p\u003e\n\u003cp\u003eThese clues do not replace a calculation, but they steer the conversation. We note them at the visit, then compare them with the measurements taken on site. If the calculation points to another size, we tell you frankly.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the heat pump adds to the furnace\u003c\/h3\u003e\n\u003cp\u003eAn electric furnace turns each kilowatt-hour into an equal amount of heat. A heat pump instead moves heat from outside to inside: at mild temperatures, it delivers two to three times more heat than the electricity it uses. That efficiency drops with the cold, which is why it makes sense to keep the furnace as backup.\u003c\/p\u003e\n\u003cp\u003eIn summer, the same circuit replaces window air conditioners. One unit outside, cool air distributed to every room through the existing ducts, and a single thermostat for both seasons.\u003c\/p\u003e\n\n\u003ch3\u003eA word about Comfortmaker\u003c\/h3\u003e\n\u003cp\u003eComfortmaker is a brand of International Comfort Products (ICP), a subsidiary of Carrier. Its R-454B evaporator coils go with its central heat pumps and air conditioners, installed on a furnace or a blower cabinet. For the homeowner, that means parts that are compatible with each other, a documented match and an AHRI number for each system.\u003c\/p\u003e\n\n\u003ch3\u003eHow the installation unfolds\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVisit: measuring the furnace, checking the blower and the electrical service.\u003c\/li\u003e\n\u003cli\u003eCoil installation in the plenum; an insulated transition is built on site if the widths differ.\u003c\/li\u003e\n\u003cli\u003eOutdoor unit installation, brazing, nitrogen test, evacuation.\u003c\/li\u003e\n\u003cli\u003eDrain, thermostat, then airflow adjustment.\u003c\/li\u003e\n\u003cli\u003eExplanation of how everything works, warranty registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAirGreen, a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company based in Montreal for more than fifteen years, carries out this work under RBQ licence 5645-9605-01.\u003c\/p\u003e\n\n\u003ch3\u003eWhat to check before choosing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil has no efficiency rating of its own: those belong to the matched system.\u003c\/li\u003e\n\u003cli\u003eThe furnace blower must deliver the system's airflow.\u003c\/li\u003e\n\u003cli\u003eThe manufacturer's limited warranty is 10 years on parts with registration within 90 days of installation, 5 years without registration.\u003c\/li\u003e\n\u003cli\u003eComfortmaker states that the ratings are published with a furnace and a wall control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert grant\u003c\/h3\u003e\n\u003cp\u003eThe matched Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation: we check it against the official list when we prepare your quote and we put the application together with you. Eligibility is judged on the complete system, not on the coil alone.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402714083620,"sku":"ESH5X30M12A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_ESH5X_ESH5X30M12A_00_2_5_TONNES_30000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765770","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-esh5x30m12a-horizontal-2-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}