{"product_id":"serpentin-devaporateur-comfortmaker-esh5x42m12a-horizontal-3-5-tonnes","title":"COMFORTMAKER ESH5X42M12A Horizontal Evaporator Coil | 3.5 Tons","description":"\u003ch2\u003eReading a quote built around the ESH5X42M12A, the 3.5-ton Comfortmaker coil\u003c\/h2\u003e\n\u003cp\u003eWhen a home is spacious, central heat pump quotes rarely look alike. One talks about \"3.5 tons\", another about \"42,000 BTU\/h\", a third settles for a model number. This text helps you connect it all around one specific part: the \u003cstrong\u003eComfortmaker ESH5X42M12A evaporator coil\u003c\/strong\u003e, a horizontal cased model, rated at 3.5 tons (42,000 BTU\/h nominal) and running on \u003cstrong\u003eR-454B refrigerant\u003c\/strong\u003e. AirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eDecoding the model name\u003c\/h3\u003e\n\u003cp\u003eIn ESH5X42M12A, the number 42 refers to the nominal size of 42,000 BTU\/h, or 3.5 tons. The range is called ESH5X. The rest of the reference identifies the configuration published by the manufacturer. We copy it as is onto our quotes, so you can check every letter with any other supplier.\u003c\/p\u003e\n\n\u003ch3\u003eThe AHRI number: the key to any comparison\u003c\/h3\u003e\n\u003cp\u003eThe coil has no efficiency rating on its own. The ratings belong to the matched system, which the AHRI number links to a specific outdoor unit. For the ESH5X42M12A, Comfortmaker publishes two systems:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eB5H0V36*K*AAA\u003c\/strong\u003e outdoor unit, AHRI 218172392, cooling 34,000 BTU\/h, heating 35,600 BTU\/h at 47 °F, SEER2 16.0, HSPF2 8.5;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eB5H3V24*K*AAA\u003c\/strong\u003e outdoor unit, AHRI 218407179, cooling 23,000 BTU\/h, heating 25,200 BTU\/h at 47 °F, SEER2 19.5, HSPF2 9.5;\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNotice the gap: the first combination delivers more capacity, the second shows better ratings. Neither is \"the right one\" in the absolute; it all depends on what your home requires. The ENERGY STAR matches published by Comfortmaker cover the SoftSound 20 \/ 23 (B5H0V, B5H3V) and Mainline 18 (C5H8T) heat pumps, all using R-454B, with ratings calculated with a furnace and a wall control (\"+WALLCON\").\u003c\/p\u003e\n\n\u003ch3\u003eThree questions to ask every contractor\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eWhat is the AHRI number of the proposed system?\u003c\/li\u003e\n\u003cli\u003eWhich outdoor unit goes with the coil?\u003c\/li\u003e\n\u003cli\u003eIs my furnace's blower sufficient, or does it need to be replaced?\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eIf any of those answers stays vague, the quote lacks precision. With us, they are in writing.\u003c\/p\u003e\n\n\u003ch3\u003eWhy 3.5 tons and not 3 or 4\u003c\/h3\u003e\n\u003cp\u003eIn a large home, with several bedrooms upstairs and a finished basement, the cooling load often exceeds what a 3-ton can handle without straining, without justifying a 4-ton. This half step avoids paying for unused capacity while leaving a reasonable margin.\u003c\/p\u003e\n\u003cp\u003eWe always verify it by calculation. An oversized unit starts and stops constantly, dries the air poorly and wears out its components faster.\u003c\/p\u003e\n\n\u003ch3\u003eHow it compares with the rest of the series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eESH5X36M12A\u003c\/strong\u003e (3 tons): same B5H0V36*K*AAA outdoor unit, the route to explore if your load is a little lower;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eESH5X42M12A\u003c\/strong\u003e (3.5 tons): the model described here;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eESH5X48M12A\u003c\/strong\u003e (4 tons): moves to the B5H0V48*K*AAA unit, for distinctly larger homes;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eESH5X24M12A\u003c\/strong\u003e and \u003cstrong\u003eESH5X30M12A\u003c\/strong\u003e (2 and 2.5 tons): reserved for small and medium homes;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eESH5X60M12A\u003c\/strong\u003e (5 tons): the largest size in the series.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAll share the same R-454B refrigerant, the TXV metering device, the cased design and the horizontal position.\u003c\/p\u003e\n\n\u003ch3\u003eWhat \"horizontal\" means\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer describes a horizontal coil with bidirectional airflow. It suits furnaces installed on their side: crawl space, attic, basement ceiling. The sloped, corrosion-resistant condensate pan sits under the exchanger and carries the water to the drain; its diameter is not published, which is why we check it on site. The refrigerant leak dissipation system is factory-mounted, according to the manufacturer's page.\u003c\/p\u003e\n\n\u003ch3\u003eThe mistakes we see most often\u003c\/h3\u003e\n\u003cp\u003eThe first is choosing the size based on the old unit. An air conditioner replaced twenty years ago was calculated for a different house, with different windows and different insulation. The second is forgetting the blower: a new coil behind a tired blower gives disappointing airflow. The third is comparing prices without comparing AHRI numbers.\u003c\/p\u003e\n\u003cp\u003eAvoiding these three traps already prevents most unpleasant surprises. We take the time to go over them with you, with plans and measurements in hand.\u003c\/p\u003e\n\n\u003ch3\u003eAbout Comfortmaker\u003c\/h3\u003e\n\u003cp\u003eA brand of International Comfort Products (ICP), a subsidiary of Carrier, Comfortmaker designs central heat pumps and air conditioners whose R-454B coils install on a furnace or a blower cabinet. The two families of outdoor units mentioned above, SoftSound and Mainline, belong to that same brand.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation day\u003c\/h3\u003e\n\u003cp\u003eWe start by protecting the floor and taking one last measurement. The coil goes into the plenum, with a custom-built insulated transition if the furnace width calls for it. Outside, the unit rests on a pad or bracket; the piping is brazed, tightness is checked with nitrogen, then the circuit is evacuated before the refrigerant is opened. The drain and the thermostat are connected, the airflow is adjusted, and we explain the whole system before we leave.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company based in Montreal for more than fifteen years, and our refrigeration, ventilation and electrical work is carried out under RBQ licence 5645-9605-01.\u003c\/p\u003e\n\n\u003ch3\u003eWarranty and registration\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer grants a 10-year limited parts warranty, provided the unit is registered within 90 days of installation; without registration, it is 5 years. We do this with you so that you do not lose the longest coverage.\u003c\/p\u003e\n\n\u003ch3\u003eWhat to check before choosing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-454B is matched with an outdoor unit using the same refrigerant, installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe furnace must have the right width and blower.\u003c\/li\u003e\n\u003cli\u003eGrants depend on the complete system, not on the coil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHeating, comfort and the bill\u003c\/h3\u003e\n\u003cp\u003ePaired with a heat pump, this coil lets you cool in summer and heat in winter through the same ducts. At mild temperatures, the heat pump delivers two to three times more heat than the electricity it uses, and the furnace takes over only when the cold intensifies. In a large home, the effect shows on the winter bill as well as on summer comfort.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert grant\u003c\/h3\u003e\n\u003cp\u003eThe matched Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation: we check it against the official list when we prepare your quote and we put the application together with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402715754788,"sku":"ESH5X42M12A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_ESH5X_ESH5X42M12A_00_3_5_TONNES_42000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765852","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-esh5x42m12a-horizontal-3-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}