{"product_id":"serpentin-devaporateur-comfortmaker-evd5x18s14b-v-1-5-tonnes","title":"COMFORTMAKER EVD5X18S14B Evaporator V-Coil | 1.5 Tons","description":"\u003ch2\u003eEVD5X18S14B: the 1.5-ton, 14-3\/16 in Comfortmaker evaporator coil for a small volume of air\u003c\/h2\u003e\n\u003cp\u003eIn a condo, a plex unit or a small house, the furnace is often compact, and the air conditioner paired with it has to be compact too. The \u003cstrong\u003eComfortmaker EVD5X18S14B evaporator coil\u003c\/strong\u003e was designed for exactly that situation: it is a cased V-coil, with a nominal capacity of 1.5 tons, or 18,000 BTU\/h. It belongs to the EVD5X series and runs on \u003cstrong\u003eR-454B\u003c\/strong\u003e refrigerant.\u003c\/p\u003e\n\u003cp\u003eAirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e. This page explains what it is for, what to check at your home and how it compares with the other models in the same series.\u003c\/p\u003e\n\n\u003ch3\u003eWhat an evaporator coil does, in two minutes\u003c\/h3\u003e\n\u003cp\u003ePicture a heat exchanger sitting in the path of the air, just above or below the furnace. The outdoor unit sends refrigerant to it, and the work happens inside its tubes: the warm air of the house passes through, gives up its heat and comes out cooler. The moisture in the air condenses along the way, drops into a pan and then goes to the drain.\u003c\/p\u003e\n\u003cp\u003eWithout a coil, a furnace can only heat. With one, the same blower and the same ductwork also cool the house. That is why this component is the link between your furnace and the outdoor unit.\u003c\/p\u003e\n\n\u003ch3\u003eThe small size: who it is for, and why\u003c\/h3\u003e\n\u003cp\u003eThe 1.5-ton size suits spaces with little volume to cool: a condo with a furnace, a plex unit that has its own forced-air system, or a small, well-insulated house. A unit that is too big for its space starts up, cools the air quickly, then shuts off before it has removed the moisture. The result is a room that is cool but clammy.\u003c\/p\u003e\n\u003cp\u003eThat is why we never pick a size by guesswork. We first calculate the heating and cooling needs of your home, then we recommend the capacity that follows from them. A properly sized system runs longer at a moderate pace, and the air stays drier.\u003c\/p\u003e\n\n\u003ch3\u003e14-3\/16 in wide: a detail that matters\u003c\/h3\u003e\n\u003cp\u003eThis model is 14-3\/16 in wide. Small furnaces often have a fairly narrow plenum, which makes this coil easy to fit. If the width of your furnace does not match exactly, we build an insulated transition on site rather than forcing the unit.\u003c\/p\u003e\n\u003cp\u003eThe coil is installed vertically, with upflow or downflow airflow, depending on the furnace configuration. The cabinet is insulated and ready to sit on the furnace: assembly is faster, and the seal is tighter than with a bare coil wrapped after the fact.\u003c\/p\u003e\n\n\u003ch3\u003eEVD5X18S14B or EVD5X19S17B: what is the difference?\u003c\/h3\u003e\n\u003cp\u003eThese two models share the same 1.5-ton capacity, the same R-454B refrigerant and the same TXV expansion valve. The practical difference is the width: 14-3\/16 in for this one, 17-1\/2 in for the EVD5X19S17B. The right choice therefore depends on your furnace, not on your comfort budget.\u003c\/p\u003e\n\u003cp\u003eFurther up the series, capacities rise to 2 tons, 2.5 tons and then 3 tons, with widths of 14-3\/16 in, 17-1\/2 in and 21 in. If your load calculation is clearly above 1.5 tons, a larger size will be more appropriate. A coil smaller than necessary never makes up for it, even if it fits the furnace well.\u003c\/p\u003e\n\n\u003ch3\u003eAdd-on heat pump: the furnace stays on the job\u003c\/h3\u003e\n\u003cp\u003ePaired with a heat pump, this coil allows what is known as an add-on setup. The furnace keeps its blower, its filters and its role as backup. In summer, the refrigerant evaporates in the coil and cools the air. In winter, the cycle reverses: the heat captured outside is delivered to the air of the house, through the same ducts.\u003c\/p\u003e\n\u003cp\u003eThe furnace takes over when the outdoor temperature falls below the threshold that we program with you. You therefore keep backup heat for the coldest days, without having to choose between two systems.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the coil does not tell you on its own\u003c\/h3\u003e\n\u003cp\u003eA coil has no efficiency rating of its own. The SEER2, EER2 and HSPF2 ratings belong to the matched system: a specific coil, a specific outdoor unit and an AHRI number that links them. When you compare two quotes, ask for that number. It is worth more than any verbal promise.\u003c\/p\u003e\n\u003cp\u003eBefore ordering, we confirm the match in the AHRI directory. As for ENERGY STAR, Comfortmaker states that serial numbers ending in B (EVD5X..S..B) are not listed there yet; only the numbers ending in A (EVD5X..M..A) are certified with the Q5H9V and N5H9V heat pumps.\u003c\/p\u003e\n\n\u003ch3\u003eEVD5X18S14B specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Comfortmaker, EVD5X series;\u003c\/li\u003e\n\u003cli\u003eType: cased evaporator coil;\u003c\/li\u003e\n\u003cli\u003eNominal capacity: 1.5 tons (18,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003eExpansion valve: TXV;\u003c\/li\u003e\n\u003cli\u003eWidth: 14-3\/16 in (360 mm);\u003c\/li\u003e\n\u003cli\u003eConnections: 3\/8 in for the liquid line, 5\/8 in for the suction line;\u003c\/li\u003e\n\u003cli\u003eCondensate: sloped PBT pan with 3 sealed plugs;\u003c\/li\u003e\n\u003cli\u003eRefrigerant leak detection: factory-installed A2L sensor, without a dissipation board. A furnace with built-in dissipation or the ACAENCDIS01A kit is therefore required;\u003c\/li\u003e\n\u003cli\u003eWarranty: 10 years on parts if you register the product within 90 days of installation, 5 years otherwise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe A2L sensor, explained simply\u003c\/h3\u003e\n\u003cp\u003eR-454B belongs to the A2L class of refrigerants, and the coil is fitted with a factory-installed leak sensor. This sensor has no dissipation board: the dissipation must therefore come from the furnace, if it has built-in dissipation, or from the ACAENCDIS01A kit. We confirm this point during the visit, before any order.\u003c\/p\u003e\n\n\u003ch3\u003eWhat a heat pump changes at home\u003c\/h3\u003e\n\u003cp\u003eAn electric furnace turns each kilowatt-hour into an equal amount of heat. A heat pump instead moves heat from the outside to the inside: in mild weather, it delivers two to three times more heat than the electricity it uses. Its efficiency drops in the cold, and that is the reason for the backup.\u003c\/p\u003e\n\u003cp\u003eIn summer, the same equipment replaces window air conditioners. One outdoor unit, cool air in every room and a single thermostat for both seasons: it is simple to live with.\u003c\/p\u003e\n\n\u003ch3\u003eOur installation in Greater Montreal\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company, based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under our RBQ licence 5645-9605-01. For this coil and its outdoor unit, the job includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace and checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum, with a custom transition if needed and airtight duct connections;\u003c\/li\u003e\n\u003cli\u003ethe outdoor unit on a pad or bracket, brazed piping, a nitrogen leak test and evacuation;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and a clear explanation of how everything works.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eBefore you buy: three checks\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil runs on R-454B: the outdoor unit must use the same refrigerant, and the two are installed together.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply to the certified match specified by the manufacturer, not to an improvised assembly.\u003c\/li\u003e\n\u003cli\u003eYour furnace must have the right width and the right blower. We confirm this on site.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIncentives: what you should know\u003c\/h3\u003e\n\u003cp\u003eEligibility for Hydro-Québec programs depends on the complete system, never on the coil alone. At the time of the quote, we check the match against the official list according to the installation date, then tell you what applies to your project.\u003c\/p\u003e\n\n\u003ch3\u003eWhy Comfortmaker\u003c\/h3\u003e\n\u003cp\u003eComfortmaker is a brand of International Comfort Products (ICP), a subsidiary of Carrier. Its R-454B coils go with the brand’s heat pumps and central air conditioners, installed on a furnace or a blower cabinet.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402705793316,"sku":"EVD5X18S14B","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EVD5X_EVD5X18S14B_00_1_5_TONNES_18000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765873","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-evd5x18s14b-v-1-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}