{"product_id":"serpentin-devaporateur-comfortmaker-evd5x24s14b-v-2-tonnes","title":"COMFORTMAKER EVD5X24S14B Evaporator V-Coil | 2 Tons","description":"\u003ch2\u003eTurning an electric furnace into a central heat pump with the 2-ton EVD5X24S14B\u003c\/h2\u003e\n\u003cp\u003eMany bungalows in the region still heat with an electric furnace: a blower, heating elements, and ducts that only get used in winter. The \u003cstrong\u003eComfortmaker EVD5X24S14B coil\u003c\/strong\u003e lets that installation work all year long. With a nominal capacity of 2 tons (24,000 BTU\/h) and a width of 14-3\/16 in, it fits on a compact furnace.\u003c\/p\u003e\n\u003cp\u003eWe install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, always with the outdoor unit that goes with it.\u003c\/p\u003e\n\n\u003ch3\u003eThe typical scenario: bungalow, electric furnace, ducts in good shape\u003c\/h3\u003e\n\u003cp\u003eIf your ducts are in good condition, you already have the most expensive part of a central system. What is missing is a heat exchanger in the path of the air and a unit outside. The EVD5X24S14B plays the first role; a Comfortmaker outdoor unit of the same capacity plays the second.\u003c\/p\u003e\n\u003cp\u003eThe result: in summer, cool air blown into every room. In winter, with a heat pump, heat delivered through the same vents, and a furnace that only steps in on the coldest days. You avoid drilling through walls for wall-mounted units in every bedroom.\u003c\/p\u003e\n\n\u003ch3\u003eWhy 2 tons?\u003c\/h3\u003e\n\u003cp\u003eCapacity is chosen according to the house, not according to preference. A well-insulated, single-storey home of average size is often comfortable with this size; a large two-storey house with a lot of glazing will need more. We do a load calculation before proposing anything, and we explain the numbers to you.\u003c\/p\u003e\n\u003cp\u003eEquipment that is too big runs short cycles, leaves the air humid and wears out its components faster. Equipment that is well chosen runs longer and more gently, and the temperature stays steady from room to room.\u003c\/p\u003e\n\n\u003ch3\u003eHow to choose it among its neighbours in the series\u003c\/h3\u003e\n\u003cp\u003eFour 2-ton coils are in the series: the EVD5X24S14B (14-3\/16 in), the EVD5X24S17B (17-1\/2 in), the EVD5X25S14B (14-3\/16 in) and the EVD5X25S17B (17-1\/2 in). On our listings, they share the same R-454B refrigerant, the same TXV expansion valve and the same capacity. What sets the EVD5X24S14B apart from its cousins is mainly the width: this one is narrower than the two 17-1\/2 in models.\u003c\/p\u003e\n\u003cp\u003eThe EVD5X25S14B shows identical characteristics on the points we publish. If one of the two is hard to get, the other may do; we always confirm the exact match before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eWhat we do on installation day\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum, with an insulated transition built on site if the widths differ, and sealed duct joints;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit on a pad or bracket, brazed piping, nitrogen test, evacuation;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment, explanation at your home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEVD5X24S14B technical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ecased evaporator coil, EVD5X series, manufacturer Comfortmaker;\u003c\/li\u003e\n\u003cli\u003e2 tons nominal (24,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003eR-454B refrigerant, TXV expansion valve;\u003c\/li\u003e\n\u003cli\u003evertical positions, upflow or downflow;\u003c\/li\u003e\n\u003cli\u003ewidth of 14-3\/16 in;\u003c\/li\u003e\n\u003cli\u003eliquid 3\/8 in, suction 5\/8 in;\u003c\/li\u003e\n\u003cli\u003esloped PBT condensate pan, 3 sealed plugs;\u003c\/li\u003e\n\u003cli\u003efactory-installed A2L leak sensor, without a dissipation board: a furnace with built-in dissipation or the ACAENCDIS01A kit must be provided;\u003c\/li\u003e\n\u003cli\u003elimited warranty of 10 years on parts, with registration within 90 days of installation (5 years without registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe coil and the furnace: a division of tasks\u003c\/h3\u003e\n\u003cp\u003eIn this setup, the furnace keeps what it does well: moving the air, filtering it and, if necessary, heating it. The coil adds cooling and, in winter, serves as the exchange point for the heat pump. It is a sharing of roles, not a replacement.\u003c\/p\u003e\n\u003cp\u003eThe outdoor temperature at which the furnace takes over is programmed with you. It depends on your home, your comfort and your electricity rate.\u003c\/p\u003e\n\n\u003ch3\u003eEfficiency: where to read the right ratings\u003c\/h3\u003e\n\u003cp\u003eA coil has no efficiency rating of its own. The SEER2, EER2 and HSPF2 values attach to a complete system identified by an AHRI number. That is the number to ask for, and it is the one we check before the order.\u003c\/p\u003e\n\u003cp\u003eComfortmaker states that serial numbers ending in B (EVD5X..S..B) are not yet listed in ENERGY STAR; only the numbers ending in A (EVD5X..M..A) are, with the Q5H9V and N5H9V heat pumps. Approved matches can be looked up in the AHRI directory.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this coil heat?\u003c\/strong\u003e Yes, when it is paired with a heat pump. With a simple central air conditioner, it only cools.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I keep my old air conditioner?\u003c\/strong\u003e Generally, no. The coil runs on R-454B and must connect to the outdoor unit designed for that refrigerant.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy furnace is not the same width.\u003c\/strong\u003e We measure it, then build an insulated transition if necessary.\u003c\/p\u003e\n\n\u003ch3\u003eOur company\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. Comfortmaker belongs to International Comfort Products (ICP), a subsidiary of Carrier.\u003c\/p\u003e\n\n\u003ch3\u003ePoints to confirm before ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-454B refrigerant shared by the coil and the outdoor unit.\u003c\/li\u003e\n\u003cli\u003ePublished ratings valid for the certified match only.\u003c\/li\u003e\n\u003cli\u003eA furnace with a suitable width and blower, checked during the visit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFinancial assistance\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec programs apply to the complete system, never to the coil alone. We validate the match against the official list at the time of the quote, taking the installation date into account.\u003c\/p\u003e\n\n\u003ch3\u003eSummer humidity: the coil’s real job\u003c\/h3\u003e\n\u003cp\u003ePeople often think an air conditioner is there to lower the temperature. It is there just as much to remove humidity. In Montreal, the muggy weeks of July make a house uncomfortable even at a reasonable temperature. A properly sized coil, with air passing through it unhurried, condenses the water out of the air and sends it down the drain.\u003c\/p\u003e\n\u003cp\u003eThat is one more reason not to oversize: a system that is too big reaches the requested temperature before it has done its work on humidity.\u003c\/p\u003e\n\n\u003ch3\u003eWhat changes in the house after installation\u003c\/h3\u003e\n\u003cp\u003eThe most visible change is the relative quiet of the heating: no more electric elements switching on at every drop of the thermostat. The heat pump supplies heat more continuously, and the furnace only starts for the coldest days. The least visible is the electricity bill, which may go down because each kilowatt-hour produces more heat than it does with simple elements.\u003c\/p\u003e\n\u003cp\u003eWe do not promise a specific figure: it depends on your house, its insulation and your habits. We prefer to show you how it is calculated during the visit.\u003c\/p\u003e\n\n\u003ch3\u003eAn installation that respects your home\u003c\/h3\u003e\n\u003cp\u003eThe existing ducts stay in place, and the coil is installed in the furnace plenum. There is no major plaster work and no opened walls, unless a piping route requires it. We protect the floors, we clean up the job site and we explain what we are doing at each step.\u003c\/p\u003e\n\u003cp\u003eThe electrical work is done under our licence, so that the connection of the outdoor unit and the thermostat is compliant.\u003c\/p\u003e\n\n\u003ch3\u003eWhen to choose a wider or larger model instead\u003c\/h3\u003e\n\u003cp\u003eIf, during the visit, we find a 17-1\/2 in furnace, we will steer you toward the EVD5X24S17B or the EVD5X25S17B. If the calculated load exceeds what 2 tons can provide, the series then offers 2.5-ton sizes (EVD5X30S14B, EVD5X30S17B, EVD5X31S17B) and 3-ton sizes. What matters is that the decision rests on a measurement, not on a hunch.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402707497252,"sku":"EVD5X24S14B","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EVD5X_EVD5X24S14B_00_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765875","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-evd5x24s14b-v-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}