{"product_id":"serpentin-devaporateur-comfortmaker-evd5x36s17b-v-3-tonnes","title":"COMFORTMAKER EVD5X36S17B Evaporator V-Coil | 3 Tons","description":"\u003ch2\u003eEVD5X36S17B: 3 tons at 17-1\/2 in, the Comfortmaker coil for a large forced-air home\u003c\/h2\u003e\n\u003cp\u003eThe bigger the house, the more heat the system has to move, and the more every detail of the installation counts. The \u003cstrong\u003eComfortmaker EVD5X36S17B evaporator coil\u003c\/strong\u003e offers 3 tons nominal (36,000 BTU\/h) in a cabinet 17-1\/2 in wide. It is a cased V-coil from the EVD5X series and runs on R-454B refrigerant.\u003c\/p\u003e\n\u003cp\u003eAirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, in two-storey houses, enlarged cottages and large bungalows.\u003c\/p\u003e\n\n\u003ch3\u003eWhen we talk about 3 tons\u003c\/h3\u003e\n\u003cp\u003eThree tons is the highest capacity in the EVD5X series. It is meant for homes whose load calculation exceeds what 2.5 tons can handle: large floor areas, high ceilings, a lot of glazing or average insulation. We recommend it only after a calculation, not on the basis of floor area.\u003c\/p\u003e\n\u003cp\u003eErring on the high side is no wiser than erring on the low side. A system that is too big runs short cycles, leaves the air clammy and puts more frequent strain on its components.\u003c\/p\u003e\n\n\u003ch3\u003eThe ducts, first judge of capacity\u003c\/h3\u003e\n\u003cp\u003eA large capacity needs a large airflow. If the ducts in the house are narrow, poorly sealed or too long, the air does not arrive in sufficient quantity in the distant rooms. We therefore inspect the accessible ducts, the blower and the plenum. A 3-ton system connected to an undersized network will disappoint, whatever the quality of the coil.\u003c\/p\u003e\n\u003cp\u003eWhen necessary, we recommend corrections: sealing, balancing or replacing a section. The choice remains yours, but you know the consequences.\u003c\/p\u003e\n\n\u003ch3\u003eNext to its 3-ton neighbours\u003c\/h3\u003e\n\u003cp\u003eThe series has three 3-ton coils. This one is the narrowest at 17-1\/2 in. The EVD5X36S21B and EVD5X37S21B are 21 in wide. All share R-454B refrigerant and the TXV expansion valve.\u003c\/p\u003e\n\u003cp\u003eIf your furnace is 17-1\/2 in wide, this model is the natural choice. If it is 21 in, one of the other two is more appropriate. Below 3 tons, the series offers 2.5-ton models in the same 17-1\/2 in width: the EVD5X30S17B and EVD5X31S17B.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel: EVD5X36S17B (Comfortmaker, EVD5X series);\u003c\/li\u003e\n\u003cli\u003eType: cased evaporator coil;\u003c\/li\u003e\n\u003cli\u003eNominal capacity: 3 tons, or 36,000 BTU\/h;\u003c\/li\u003e\n\u003cli\u003eWidth: 17-1\/2 in;\u003c\/li\u003e\n\u003cli\u003eR-454B refrigerant, TXV expansion valve;\u003c\/li\u003e\n\u003cli\u003eVertical installation, upflow or downflow;\u003c\/li\u003e\n\u003cli\u003e3\/8 in liquid connection, 3\/4 in suction connection;\u003c\/li\u003e\n\u003cli\u003eSloped PBT condensate pan, 3 sealed plugs;\u003c\/li\u003e\n\u003cli\u003eFactory-installed A2L leak sensor, without a dissipation board: furnace with built-in dissipation or the ACAENCDIS01A kit;\u003c\/li\u003e\n\u003cli\u003eLimited warranty of 10 years on parts with registration within 90 days of installation, 5 years without registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe condensate of a large house\u003c\/h3\u003e\n\u003cp\u003eThe bigger the system, the more water it removes from the air on muggy days. The sloped pan of the EVD5X36S17B, with its 3 sealed plugs, lets the outlet be directed to the most convenient drain. We check that the flow is free and the slope is sufficient, because an overflowing drain causes water damage that is noticed too late.\u003c\/p\u003e\n\n\u003ch3\u003eHeat pump and furnace: sharing the seasons\u003c\/h3\u003e\n\u003cp\u003eWith a heat pump, this coil makes it possible to heat through the existing ducts. The furnace keeps its blower, its filters and its backup role. In mild weather, the heat pump supplies two to three times more heat than the electricity it consumes; it loses efficiency when it is very cold, and that is when the furnace takes over, below the threshold that we program with you.\u003c\/p\u003e\n\u003cp\u003eIn a large house, this sharing of tasks can make a noticeable difference on the electricity bill, but we do not promise a figure: it all depends on insulation, habits and the rate.\u003c\/p\u003e\n\n\u003ch3\u003eRatings and certification\u003c\/h3\u003e\n\u003cp\u003eA coil has no efficiency rating of its own; the SEER2, EER2 and HSPF2 values attach to a matched system identified by an AHRI number. We confirm it before ordering. Comfortmaker also states that serial numbers ending in B (EVD5X..S..B) are not yet listed in ENERGY STAR; only those ending in A (EVD5X..M..A) are certified there with the Q5H9V and N5H9V heat pumps.\u003c\/p\u003e\n\n\u003ch3\u003eThe job\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum, insulated transition if needed, sealed duct joints;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit on a pad or bracket, brazed piping, nitrogen leak test, evacuation;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment, explanation of how it works.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our work is done under RBQ licence 5645-9605-01. Comfortmaker belongs to International Comfort Products (ICP), a subsidiary of Carrier.\u003c\/p\u003e\n\n\u003ch3\u003eTo check before you buy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-454B is shared by the coil and the outdoor unit, installed together.\u003c\/li\u003e\n\u003cli\u003eThe ratings apply to the certified match.\u003c\/li\u003e\n\u003cli\u003eThe furnace has the width, the blower and the ducts to handle a 3-ton system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA two-storey house: the question of distribution\u003c\/h3\u003e\n\u003cp\u003eIn a house with several floors, cool air sinks and warm air rises. In summer, the upper floor is often hotter than the ground floor; in winter, it is the reverse. A well-adjusted system, with airflow balanced between the vents, reduces this gap. We therefore look at how the ducts serve each floor before proposing anything.\u003c\/p\u003e\n\u003cp\u003eSometimes a simple adjustment of the registers is enough to rebalance. Sometimes a modification to a section is needed. We tell you plainly.\u003c\/p\u003e\n\n\u003ch3\u003eWhy we do not promise a savings figure\u003c\/h3\u003e\n\u003cp\u003eA heat pump paired with this coil can reduce the heating consumption of a home heated with electricity, because it moves heat instead of producing it. But the exact amount depends on insulation, air tightness, the temperature you maintain and the electricity rate. A single figure would be a disservice.\u003c\/p\u003e\n\u003cp\u003eWhat we can do is explain the mechanism and show you on site where the main possible gains lie.\u003c\/p\u003e\n\n\u003ch3\u003eAfter installation\u003c\/h3\u003e\n\u003cp\u003eRemember to register the unit within 90 days after installation: that is what takes the parts warranty from 5 to 10 years. Keep the invoice and the model number, EVD5X36S17B, close at hand.\u003c\/p\u003e\n\n\u003ch3\u003eOne last piece of advice before deciding\u003c\/h3\u003e\n\u003cp\u003eAsk yourself whether your load calculation has really been done. Many systems are chosen based on the size of the old unit, which may itself have been poorly chosen. A calculation done on site, with your windows, your insulation and your ducts, is worth more than any rule of thumb.\u003c\/p\u003e\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eEligibility for Hydro-Québec programs concerns the complete system. We check the match against the official list at the quote, according to the installation date, and tell you what applies.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402715558180,"sku":"EVD5X36S17B","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EVD5X_EVD5X36S17B_00_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765875","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-evd5x36s17b-v-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}