{"product_id":"serpentin-devaporateur-comfortmaker-evd5x42s17b-v-3-5-tonnes","title":"COMFORTMAKER EVD5X42S17B Evaporator V-Coil | 3.5 Tons","description":"\u003ch2\u003eThe EVD5X42S17B, or how to fit 3.5 tons into a narrow furnace\u003c\/h2\u003e\n\u003cp\u003eSome homes need a little more capacity than a 3-ton system, but their furnace is nothing imposing. That is the situation the \u003cstrong\u003eComfortmaker EVD5X42S17B evaporator coil\u003c\/strong\u003e solves: a nominal size of 3.5 tons (42,000 BTU\/h) in a cabinet only 17-1\/2 in wide, with \u003cstrong\u003eR-454B refrigerant\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis page answers the questions homeowners in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e most often ask before choosing this model.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is an evaporator coil for?\u003c\/h3\u003e\n\u003cp\u003eIt is the part where the air in the house meets the cold. The refrigerant, sent by the outdoor unit, circulates through finned tubes; the warm air passing through gives up its heat and its moisture. Nothing else in your system directly cools the air you breathe.\u003c\/p\u003e\n\u003cp\u003eHere, the tubes are folded into a V inside an insulated cabinet. This shape provides a large exchange surface in a compact volume, which makes it attractive in a modest-sized furnace.\u003c\/p\u003e\n\n\u003ch3\u003eWhy 3.5 tons rather than 3?\u003c\/h3\u003e\n\u003cp\u003eA half size more is the right move when the house has been enlarged, when a sunroom has been added or when afternoon sun exposure pushes a 3-ton unit to its limits. We always check this with a simple load calculation during the visit: floor area, insulation, windows, number of occupants.\u003c\/p\u003e\n\u003cp\u003eThat said, bigger is not always better. If your house gets by with the 3-ton, the EVD5X38S17B, which has the same width, is the logical choice. We will tell you so frankly.\u003c\/p\u003e\n\n\u003ch3\u003eA system that also heats, if the outdoor unit is a heat pump\u003c\/h3\u003e\n\u003cp\u003eThe coil handles air conditioning in every case. With a matched heat pump, it also works in winter: the refrigerant warmed outside gives up its heat to the air passing through the cabinet. The furnace stays in place with its blower and filters, and takes over when the outdoor temperature falls below the threshold we set with you.\u003c\/p\u003e\n\u003cp\u003eWith a simple central air conditioner, on the other hand, the coil only does the cooling.\u003c\/p\u003e\n\n\u003ch3\u003eHow the coil is installed\u003c\/h3\u003e\n\u003cp\u003eIt is installed vertically, with upflow or downflow airflow, on top of the furnace or beneath it. Since it is already in its insulated cabinet, there is no box to build: we mount it, seal the joints and connect the piping. The liquid connection is 3\/8 in and the suction connection is 7\/8 in.\u003c\/p\u003e\n\u003cp\u003eThe TXV metering device adjusts the refrigerant to the load. The condensate pan, made of PBT and sloped, empties the water toward the drain thanks to three sealed plugs that adapt to the position of the pipe.\u003c\/p\u003e\n\n\u003ch3\u003eIs my furnace the right width?\u003c\/h3\u003e\n\u003cp\u003eThe coil measures 17-1\/2 in. If your furnace is the same width, the installation goes in a straight line. If not, we build an insulated transition on site, after measuring at your home. This step is part of the estimate visit; nothing is ordered before we have checked.\u003c\/p\u003e\n\u003cp\u003eThe blower matters as much as the width. A 3.5-ton size needs more air than a 3-ton, and a blower that is too tight reduces comfort. We check its airflow, the size of the plenum and the condition of the return air.\u003c\/p\u003e\n\n\u003ch3\u003eThe comfort you notice in practice\u003c\/h3\u003e\n\u003cp\u003eA well-sized system starts its cooling, reaches the requested temperature and holds that level without abrupt cycling. The house cools evenly, and the air loses its moisture as it passes over the cold tubes. Occupants mostly notice two things: a less stuffy upper floor and easier nights.\u003c\/p\u003e\n\u003cp\u003eThe 3.5-ton capacity also serves homes where the air distribution is generous, with several vents per floor. In a small house with a limited duct network, it would be pointless, because the air has nowhere to go; that is why we talk about airflow before we talk about tonnage.\u003c\/p\u003e\n\n\u003ch3\u003eWhich outdoor unit should you choose?\u003c\/h3\u003e\n\u003cp\u003eA Comfortmaker unit of the same capacity and the same refrigerant. The exact match goes through the AHRI directory, where we note the number of the certified system before ordering. That number is what ties efficiency ratings to the coil-plus-outdoor-unit assembly.\u003c\/p\u003e\n\u003cp\u003eA clarification from Comfortmaker: serial numbers with a B (EVD5X..S..B) are not yet listed in ENERGY STAR, while serial numbers with an A (EVD5X..M..A) are certified there with the Q5H9V and N5H9V heat pumps. The AHRI directory lists the approved matches.\u003c\/p\u003e\n\n\u003ch3\u003eEVD5X42S17B, EVD5X42S21B or EVD5X42S24B?\u003c\/h3\u003e\n\u003cp\u003eThese three models offer the same 3.5-ton capacity, the same R-454B and the same TXV metering device. Only the width changes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e17-1\/2 in: the EVD5X42S17B, for narrow furnaces;\u003c\/li\u003e\n\u003cli\u003e21 in: the EVD5X42S21B, for mid-width furnaces;\u003c\/li\u003e\n\u003cli\u003e24-1\/2 in: the EVD5X42S24B, for large furnaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe right model is the one whose width fits your equipment. Between this model and the EVD5X38S17B, the width is identical; only the capacity, 3 tons against 3.5, separates them.\u003c\/p\u003e\n\n\u003ch3\u003eEVD5X42S17B features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003etype: cased evaporator coil, EVD5X series;\u003c\/li\u003e\n\u003cli\u003esize: 3.5 tons (42,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003ewidth: 17-1\/2 in;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in liquid, 7\/8 in suction;\u003c\/li\u003e\n\u003cli\u003emetering device: TXV;\u003c\/li\u003e\n\u003cli\u003edrain: sloped PBT pan, three sealed plugs;\u003c\/li\u003e\n\u003cli\u003eleak detection: factory A2L sensor with no mitigation board, which requires a furnace with built-in mitigation or the ACAENCDIS01A kit;\u003c\/li\u003e\n\u003cli\u003e10-year limited warranty on parts with registration within 90 days after installation, 5 years without registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat AirGreen's installation includes\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 for its refrigeration, ventilation and electrical work. For this coil, the job covers:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace and checking the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum and sealing the air connections;\u003c\/li\u003e\n\u003cli\u003ethe outdoor unit on a bracket, brazed piping, the nitrogen test and the vacuum;\u003c\/li\u003e\n\u003cli\u003ethe condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003estart-up, airflow adjustment and a full demonstration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eReplacing an old central air conditioner\u003c\/h3\u003e\n\u003cp\u003eIf your home already has a central air conditioner, the temptation is to change only the outdoor unit. With this coil, that is not possible: it runs on R-454B and must be matched with the unit specified by the manufacturer. An old coil and an old unit using a different refrigerant do not mix with this system.\u003c\/p\u003e\n\u003cp\u003eThe upside: a complete replacement, coil and unit together, brings back a manufacturer's warranty on parts and a system in which every element was chosen to work with the others. We keep the furnace, its filters and its air network as they are, unless the visit reveals a defect that needs correcting.\u003c\/p\u003e\n\n\u003ch3\u003ePoints to confirm before ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe same refrigerant, R-454B, for the coil and the outdoor unit, installed together.\u003c\/li\u003e\n\u003cli\u003ePublished ratings that apply to the certified system, not to mismatched parts.\u003c\/li\u003e\n\u003cli\u003eA furnace of the right width with a blower that delivers the system's airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFinancial assistance\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec programs apply to the complete system. We check the official list based on the installation date and tell you in the quote what applies to your project.\u003c\/p\u003e\n\n\u003ch3\u003eLet's look at your home's numbers\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate. We measure the furnace, assess the electrical service and write up a quote for the complete Comfortmaker system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402718998820,"sku":"EVD5X42S17B","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EVD5X_EVD5X42S17B_00_3_5_TONNES_42000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765877","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-evd5x42s17b-v-3-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}