{"product_id":"serpentin-devaporateur-comfortmaker-evd5x42s21b-v-3-5-tonnes","title":"COMFORTMAKER EVD5X42S21B Evaporator V-Coil | 3.5 Tons","description":"\u003ch2\u003eEVD5X42S21B: 3.5 tons, 21 in wide, the middle size of the series\u003c\/h2\u003e\n\u003cp\u003eOn paper, three 3.5-ton Comfortmaker coils look alike. In your basement, they are very different, because what matters is the metal box they sit on. The \u003cstrong\u003eComfortmaker EVD5X42S21B evaporator coil\u003c\/strong\u003e is 21 in wide: it sits in the middle between the narrow 17-1\/2 in version and the wide 24-1\/2 in version. Nominal size of 3.5 tons, or 42,000 BTU\/h, with \u003cstrong\u003eR-454B refrigerant\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWe install it for homeowners in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eStart with the furnace, not the catalogue\u003c\/h3\u003e\n\u003cp\u003eMany people choose a capacity first, then look for a coil. We work the other way around. A tape measure, the furnace's nameplate, a look at the plenum: that is what determines the width. Once the width is known, two or three models remain to be sorted out by capacity.\u003c\/p\u003e\n\u003cp\u003eThe EVD5X42S21B is the right candidate when the furnace is 21 in wide, or close to it, so that a simple transition is enough to connect the two.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the V shape brings\u003c\/h3\u003e\n\u003cp\u003eTwo faces of tubes arranged in a V share the cabinet. The air passes through them, flowing around them over their whole surface, and the condensation water runs down to the pan instead of staying trapped in the fins. The insulated cabinet prevents losses and limits condensation on the outside of the plenum.\u003c\/p\u003e\n\u003cp\u003eThe installation is vertical, with upflow or downflow airflow, depending on where the blower is: the manufacturer lists no other position.\u003c\/p\u003e\n\n\u003ch3\u003eAn add-on system, step by step\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eThe outdoor unit compresses the refrigerant and sends it to the coil.\u003c\/li\u003e\n\u003cli\u003eThe TXV metering device controls how much refrigerant enters the tubes.\u003c\/li\u003e\n\u003cli\u003eThe refrigerant evaporates, absorbs heat from the air and returns to the outdoor unit to start again.\u003c\/li\u003e\n\u003cli\u003eThe furnace blower distributes the cooled air through the existing ducts.\u003c\/li\u003e\n\u003cli\u003eWith a heat pump, the direction of the cycle reverses in winter and the same coil warms the air.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe furnace keeps its backup role: it takes over when the outdoor temperature drops below the threshold we set with you.\u003c\/p\u003e\n\n\u003ch3\u003e3.5-ton capacity: who is it for?\u003c\/h3\u003e\n\u003cp\u003eCottages, somewhat large single-storey homes and well-insulated two-storey houses. The more rooms the duct network serves, the greater the airflow required, and the more the furnace blower has to measure up. We measure it, along with the plenum and the returns, before confirming the size.\u003c\/p\u003e\n\n\u003ch3\u003eA drier house, not just a cooler one\u003c\/h3\u003e\n\u003cp\u003eSummer comfort depends as much on humidity as on temperature. Air at the same temperature but loaded with water feels heavy, sticks to the skin and encourages a musty smell in the basement. As it passes through the cold tubes, the air sheds part of its water vapour, which condenses in the pan and then flows out through the drain. That is why a well-sized central air conditioning system changes the feel of Montreal summers far more than window units that serve only one room.\u003c\/p\u003e\n\u003cp\u003eA system that is too big would do the opposite: it would shut off before it had time to dry the air. The load calculation done during the visit is there to avoid this trap, which is why it is important not to choose the capacity out of habit alone.\u003c\/p\u003e\n\n\u003ch3\u003eMatching and efficiency ratings\u003c\/h3\u003e\n\u003cp\u003eThe coil has no rating of its own. The published ratings belong to the certified system, the one that pairs this coil with a Comfortmaker outdoor unit of the same capacity and the same refrigerant. We find that system in the AHRI directory, with its number, before ordering.\u003c\/p\u003e\n\u003cp\u003eA note from the manufacturer: serial numbers with a B (EVD5X..S..B) are not yet listed in ENERGY STAR, unlike serial numbers with an A (EVD5X..M..A), which are certified with the Q5H9V and N5H9V heat pumps. For approved matches, AHRI is the authority.\u003c\/p\u003e\n\n\u003ch3\u003eThe three 3.5-ton models side by side\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eEVD5X42S17B\u003c\/strong\u003e: 17-1\/2 in, for a narrow furnace.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVD5X42S21B\u003c\/strong\u003e (this one): 21 in, for a mid-size furnace.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVD5X42S24B\u003c\/strong\u003e: 24-1\/2 in, for a wide furnace.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf your need is closer to 4 tons with the same 21 in width, look at the EVD5X48S21B. And if the target capacity is 5 tons at 21 in, two models exist, the EVD5X60S21B and the EVD5X61S21B. All of these models use R-454B and the TXV metering device.\u003c\/p\u003e\n\n\u003ch3\u003eEVD5X42S21B spec sheet\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003etype: cased evaporator coil;\u003c\/li\u003e\n\u003cli\u003eseries: EVD5X;\u003c\/li\u003e\n\u003cli\u003enominal size: 3.5 tons (42,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003ewidth: 21 in;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in for the liquid, 7\/8 in for the suction;\u003c\/li\u003e\n\u003cli\u003emetering device: TXV;\u003c\/li\u003e\n\u003cli\u003econdensate pan: PBT, sloped, three sealed plugs;\u003c\/li\u003e\n\u003cli\u003eleak detection: factory-installed A2L sensor, no mitigation board; furnace with built-in mitigation or ACAENCDIS01A kit required;\u003c\/li\u003e\n\u003cli\u003ewarranty: 10-year limited warranty on parts if registered within 90 days of installation, otherwise 5 years.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow we work\u003c\/h3\u003e\n\u003cp\u003eAirGreen, a family-owned heating and cooling company based in Montreal for more than fifteen years, works under RBQ licence 5645-9605-01. On this job, we:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasure the furnace and check the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstall the coil in the plenum and seal the air joints, with a transition built on site if necessary;\u003c\/li\u003e\n\u003cli\u003einstall the outdoor unit, braze the piping, run the nitrogen test and pull the vacuum;\u003c\/li\u003e\n\u003cli\u003econnect the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003estart the system, adjust the airflow and explain how it works.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eQuestions we often hear\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMy furnace is a little under 21 in. Is that a problem?\u003c\/strong\u003e No. We build an insulated transition on site and work it into the plenum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I keep my current air conditioner?\u003c\/strong\u003e Generally, no. The coil runs on R-454B and is matched with the outdoor unit specified by the manufacturer; we install the complete system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the furnace become useless with a heat pump?\u003c\/strong\u003e Quite the opposite: it keeps its blower and its filters, and serves as backup heat during the coldest weather.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this coil heat?\u003c\/strong\u003e Yes, when it is connected to a heat pump. With a central air conditioner, it only cools.\u003c\/p\u003e\n\n\u003ch3\u003eThree checks before buying\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-454B refrigerant for the whole system: coil and outdoor unit are installed together.\u003c\/li\u003e\n\u003cli\u003ePublished ratings valid for the certified match only.\u003c\/li\u003e\n\u003cli\u003eFurnace width and blower airflow confirmed during the visit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHydro-Québec programs\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec programs assess the complete system, not an isolated part. At the time of the quote, we check the official list based on the installation date and tell you what applies.\u003c\/p\u003e\n\n\u003ch3\u003eNext step: a visit with a tape measure\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate. We measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e lets you spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402721063204,"sku":"EVD5X42S21B","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EVD5X_EVD5X42S21B_00_3_5_TONNES_42000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765874","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-evd5x42s21b-v-3-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}