{"product_id":"serpentin-devaporateur-comfortmaker-evd5x42s24b-v-3-5-tonnes","title":"COMFORTMAKER EVD5X42S24B Evaporator V-Coil | 3.5 Tons","description":"\u003ch2\u003eA wide furnace, a coil to match: the 3.5-ton EVD5X42S24B\u003c\/h2\u003e\n\u003cp\u003eOlder cottage and townhouse furnaces are often wider than those in recent construction. For this kind of cabinet, a transition costs time, and a coil that is too narrow lets air slip past the tubes. The \u003cstrong\u003eComfortmaker EVD5X42S24B evaporator coil\u003c\/strong\u003e settles the question with its 24-1\/2 in width, the largest in the series for this capacity. It offers a nominal 3.5 tons (42,000 BTU\/h) and uses \u003cstrong\u003eR-454B refrigerant\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eAirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhy width matters so much\u003c\/h3\u003e\n\u003cp\u003eAll the air in the house has to pass through the coil. If the cross-section of the cabinet does not match that of the plenum, you lose air tightness, you create zones where air races by without being cooled and you complicate the installation. On a wide furnace, a coil of the same width fits together without tricks: the joints are short, the sealing is clean and the result lasts longer.\u003c\/p\u003e\n\u003cp\u003eConversely, mounting a 24-1\/2 in coil on a narrow furnace is possible, but it means building a more pronounced transition. We build and insulate it on site when it is needed, but we would rather not need it.\u003c\/p\u003e\n\n\u003ch3\u003eThe cabinet supplied with the coil\u003c\/h3\u003e\n\u003cp\u003eThis model arrives in its insulated cabinet. On a job site, that means fewer parts to assemble and a sealed enclosure from the moment of delivery. The condensate pan, made of PBT, is sloped to empty the water completely; it offers three sealed plugs so the drain outlet can be chosen to suit the layout of the mechanical room.\u003c\/p\u003e\n\u003cp\u003eThe installation is vertical, with upflow or downflow airflow: the manufacturer lists these two positions. The metering device is a TXV, which adapts the refrigerant flow to the coil's needs. The connections are 3\/8 in for the liquid and 7\/8 in for the suction.\u003c\/p\u003e\n\n\u003ch3\u003eWhen to choose a 3.5-ton coil\u003c\/h3\u003e\n\u003cp\u003eThink of it as the happy medium: more generous than the 3-ton for homes with many rooms or a lot of glass, more measured than the 4-ton for those that do not need all that airflow. Two-storey cottages, long single-storey homes and townhouses with a finished basement are natural candidates.\u003c\/p\u003e\n\u003cp\u003eWe do not gamble on capacity. A load calculation, measuring the ducts and the plenum, then checking the blower: that is what justifies the size before any order.\u003c\/p\u003e\n\n\u003ch3\u003eAir conditioning in summer, heating in winter\u003c\/h3\u003e\n\u003cp\u003eMatched with a central air conditioner, it cools and dries the air in the house. Matched with a heat pump, it also heats, using the ducts you already have. In winter, the cycle turns around: the refrigerant warmed outside gives up its heat to the air passing through the cabinet.\u003c\/p\u003e\n\u003cp\u003eThe furnace does not disappear. It keeps its blower, its filters and its heating elements, and takes over during the coldest weather. The switchover threshold is set with you, according to your comfort and your electricity bill.\u003c\/p\u003e\n\n\u003ch3\u003eChoosing between the three 3.5-ton widths\u003c\/h3\u003e\n\u003cp\u003eThe capacity, the refrigerant, the metering device and the cabinet are identical from one model to the next. What differs:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eEVD5X42S17B\u003c\/strong\u003e: 17-1\/2 in, for compact furnaces;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVD5X42S21B\u003c\/strong\u003e: 21 in, for intermediate widths;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVD5X42S24B\u003c\/strong\u003e (this model): 24-1\/2 in, for wide furnaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOther models share this 24-1\/2 in width with a higher capacity: the 4-ton EVD5X48S24B and EVD5X49S24B, as well as the 5-ton EVD5X60S24B and EVD5X61S24B. If your furnace is wide but the house only calls for 3.5 tons, this is where you stop.\u003c\/p\u003e\n\n\u003ch3\u003eA typical job with a wide furnace\u003c\/h3\u003e\n\u003cp\u003eTake a South Shore cottage built several decades ago. The furnace, in the basement, was chosen to heat the whole house and its cabinet is generous. An original central air conditioner, still in place, no longer cools as it used to. The owner wants a system that cools better and can also heat, to reduce reliance on the furnace.\u003c\/p\u003e\n\u003cp\u003eWe measure, we find that the 24-1\/2 in width matches the opening, and we propose a heat pump matched with this coil. The furnace is kept, and so is its duct network. Once the work is done, the house goes from a tired air conditioner to a complete system that handles summer and a significant part of winter.\u003c\/p\u003e\n\u003cp\u003eThis scenario is not universal, but it illustrates why we start with the box that receives the coil before talking about brand or capacity.\u003c\/p\u003e\n\n\u003ch3\u003eThe certified match\u003c\/h3\u003e\n\u003cp\u003eThe coil does not display an efficiency rating of its own. The published ratings apply to a certified system: this coil, a Comfortmaker outdoor unit of the same capacity and the same refrigerant, and an AHRI number that links them. We check this number in the directory before ordering, and it is the one we ask you to compare between quotes.\u003c\/p\u003e\n\u003cp\u003eManufacturer's detail: serial numbers with a B (EVD5X..S..B) are not yet in ENERGY STAR; only serial numbers with an A (EVD5X..M..A) are certified there with the Q5H9V and N5H9V heat pumps.\u003c\/p\u003e\n\n\u003ch3\u003eEVD5X42S24B technical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003etype: cased evaporator coil;\u003c\/li\u003e\n\u003cli\u003eseries: EVD5X;\u003c\/li\u003e\n\u003cli\u003enominal size: 3.5 tons (42,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003ewidth: 24-1\/2 in;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in liquid, 7\/8 in suction;\u003c\/li\u003e\n\u003cli\u003emetering device: TXV;\u003c\/li\u003e\n\u003cli\u003epositions: vertical, upflow or downflow;\u003c\/li\u003e\n\u003cli\u003eleak detection: factory A2L sensor, no mitigation board; furnace with built-in mitigation or ACAENCDIS01A kit required;\u003c\/li\u003e\n\u003cli\u003ewarranty: 10-year limited warranty on parts with registration within 90 days of installation, 5 years without registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAn installation done by the book\u003c\/h3\u003e\n\u003cp\u003eA family-owned heating and cooling company in Montreal for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01. For this coil and its outdoor unit, here is how the work unfolds:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstallation in the plenum with sealing of the duct joints;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit on a pad or bracket, brazed piping, nitrogen leak test, vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment, explanations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA mechanical room with room to breathe\u003c\/h3\u003e\n\u003cp\u003eA wide coil also needs space around it: clearance for service, access to the condensate pan, room for the filter. We check that the mechanical room allows easy inspection in the future, because equipment that is accessible is equipment that gets maintained.\u003c\/p\u003e\n\n\u003ch3\u003eTo check before deciding\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-454B requires an outdoor unit with the same refrigerant, installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe advertised ratings belong to the certified match.\u003c\/li\u003e\n\u003cli\u003eThe furnace width and the capacity of its blower are confirmed on site.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec assesses the complete system, not the coil alone. We check the official list at the time of the quote, based on the installation date, and we tell you what applies to your home.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFree on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402707071268,"sku":"EVD5X42S24B","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EVD5X_EVD5X42S24B_00_3_5_TONNES_42000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765876","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-evd5x42s24b-v-3-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}