{"product_id":"serpentin-devaporateur-comfortmaker-evd5x48s21b-v-4-tonnes","title":"COMFORTMAKER EVD5X48S21B Evaporator V-Coil | 4 Tons","description":"\u003ch2\u003eEVD5X48S21B: 4 tons in 21 in for the two-storey house with a finished basement\u003c\/h2\u003e\n\u003cp\u003eWhen the primary bedroom upstairs is always the last room to cool down, the unit's capacity is not always the problem: it is often a lack of airflow. The \u003cstrong\u003eComfortmaker EVD5X48S21B evaporator coil\u003c\/strong\u003e was designed for homes where the air conditioning has to serve several levels. It offers a nominal 4 tons (48,000 BTU\/h), fits in a cabinet 21 in wide and runs on \u003cstrong\u003eR-454B refrigerant\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWe install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, in two-storey homes, spacious single-storey homes and enlarged semi-detached houses.\u003c\/p\u003e\n\n\u003ch3\u003eThe coil's role in the cooling chain\u003c\/h3\u003e\n\u003cp\u003eA central air conditioning system is made up of three elements that work as a team: the outdoor unit, which compresses the refrigerant; the coil, which evaporates it indoors; and the furnace blower, which pushes the air through the tubes and into the ducts. None of the three works alone. The coil is the one that absorbs the heat from the house and collects the water that the air leaves behind.\u003c\/p\u003e\n\n\u003ch3\u003eWhat 4 tons means\u003c\/h3\u003e\n\u003cp\u003eThe 48,000 BTU\/h figure on the spec sheet is a nominal size: it places the coil in the range, but it does not by itself describe the comfort you will get. This capacity is suitable when the house is large, has a lot of glass or is spread over several levels. In a more modest house, it would be too much and would cause short cycles that leave the air humid.\u003c\/p\u003e\n\u003cp\u003eThe question to ask is therefore not \"how many tons can I afford?\" but \"how many does the house call for?\" Our visit answers that question with measurements, not with an impression.\u003c\/p\u003e\n\n\u003ch3\u003eWhy the blower has to pass the test\u003c\/h3\u003e\n\u003cp\u003eThe larger the size, the more air has to circulate. A furnace blower that is too weak for a 4-ton system leads to uneven comfort and wears on the equipment. We assess its airflow, the size of the plenum and the cross-section of the return air before confirming this model. If the distribution is inadequate, we tell you, and we offer to correct the duct network or choose a smaller size.\u003c\/p\u003e\n\n\u003ch3\u003eThe 21 in width: the advantage of compactness\u003c\/h3\u003e\n\u003cp\u003eAt this capacity, you would expect a wider cabinet. Yet this model offers 4 tons in 21 in, while its twin of the same capacity, the EVD5X48S24B, measures 24-1\/2 in. For a mid-width furnace, the 21 in version avoids a transition; for a wide furnace, the 24-1\/2 in version is the one to pick. When the furnace is narrower than the coil, we build an insulated transition on site.\u003c\/p\u003e\n\n\u003ch3\u003eA summer day in a two-level house\u003c\/h3\u003e\n\u003cp\u003eCool air is heavier than warm air: it naturally sinks toward the basement and leaves the upper floor lagging behind. A well-balanced central system compensates by pushing air toward the bedrooms, thanks to a sufficient blower and well-distributed vents. The 4-ton coil provides the cooling capacity; the furnace and its duct network take care of the distribution.\u003c\/p\u003e\n\u003cp\u003eThat is why we always ask, during the estimate, whether some rooms are warmer than others. An answer like \"the office on the second floor\" tells us as much about the duct network as about the coil.\u003c\/p\u003e\n\n\u003ch3\u003eConstruction details\u003c\/h3\u003e\n\u003cp\u003eThe coil is a V-coil model with an insulated cabinet, installed vertically with upflow or downflow airflow. It has a TXV metering device, a sloped PBT condensate pan with three sealed plugs, a 3\/8 in liquid connection and a 7\/8 in suction connection. Because the whole cabinet is delivered ready to install, air tightness is better and assembly is faster.\u003c\/p\u003e\n\n\u003ch3\u003eAdd-on heat pump: the furnace keeps its post\u003c\/h3\u003e\n\u003cp\u003ePaired with a heat pump, the coil also heats in winter. The furnace then keeps its blower, its filters and its heating elements, and steps in as backup when the outdoor temperature falls below the threshold we set with you. In a large electrically heated home, the part of the season covered by the heat pump weighs heavily on the bill, since a heat pump moves heat instead of producing it: in mild temperatures, it delivers two to three times more heat than the electricity it consumes.\u003c\/p\u003e\n\n\u003ch3\u003eChoosing between the 4-ton models and their neighbours\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eEVD5X48S21B\u003c\/strong\u003e (this model): 4 tons, 21 in;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVD5X48S24B\u003c\/strong\u003e and \u003cstrong\u003eEVD5X49S24B\u003c\/strong\u003e: 4 tons, 24-1\/2 in;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVD5X42S21B\u003c\/strong\u003e: 3.5 tons, the same 21 in width, if the house calls for less capacity;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVD5X60S21B\u003c\/strong\u003e and \u003cstrong\u003eEVD5X61S21B\u003c\/strong\u003e: 5 tons, the same 21 in width, for the largest homes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAll the models in the series have the same R-454B refrigerant and the same TXV metering device. Only the capacity and the width change the decision.\u003c\/p\u003e\n\n\u003ch3\u003eMatching, AHRI and ENERGY STAR\u003c\/h3\u003e\n\u003cp\u003eThis coil pairs with a Comfortmaker outdoor unit of the same capacity and the same refrigerant. The efficiency ratings are those of the certified match, with its AHRI number, which we check in the directory before ordering. To compare two quotes, look at this number rather than the slogans.\u003c\/p\u003e\n\u003cp\u003eComfortmaker points out that serial numbers with a B (EVD5X..S..B) are not yet in ENERGY STAR, while serial numbers with an A (EVD5X..M..A) are certified there with the Q5H9V and N5H9V heat pumps.\u003c\/p\u003e\n\n\u003ch3\u003eEVD5X48S21B spec sheet\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003etype: cased evaporator coil, EVD5X series;\u003c\/li\u003e\n\u003cli\u003esize: 4 tons (48,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003ewidth: 21 in;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in liquid, 7\/8 in suction;\u003c\/li\u003e\n\u003cli\u003emetering device: TXV;\u003c\/li\u003e\n\u003cli\u003epositions: vertical, upflow or downflow;\u003c\/li\u003e\n\u003cli\u003eleak detection: factory-installed A2L sensor, no mitigation board; furnace with built-in mitigation or ACAENCDIS01A kit required;\u003c\/li\u003e\n\u003cli\u003ewarranty: 10-year limited warranty on parts with registration within 90 days of installation, 5 years without registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow the installation unfolds\u003c\/h3\u003e\n\u003cp\u003eAirGreen has been a family-owned heating and cooling company in Montreal for more than fifteen years, under RBQ licence 5645-9605-01. Our team:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasures the furnace, checks the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalls the coil and seals the plenum joints;\u003c\/li\u003e\n\u003cli\u003einstalls the outdoor unit, brazes the piping, runs the nitrogen test and the vacuum;\u003c\/li\u003e\n\u003cli\u003econnects the drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003eadjusts the airflow and guides you through commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat we do not promise\u003c\/h3\u003e\n\u003cp\u003eWe do not guarantee a bill amount or a precise temperature. Actual savings depend on insulation, air tightness, the thermostat and your habits. What we do ensure is a system in which every part was chosen to work with the others, installed according to the standards of the trade and clearly explained.\u003c\/p\u003e\n\n\u003ch3\u003eBefore choosing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil and the outdoor unit share R-454B and are installed together.\u003c\/li\u003e\n\u003cli\u003eThe advertised ratings apply to the certified system.\u003c\/li\u003e\n\u003cli\u003eThe furnace must offer the right width and enough airflow for 4 tons.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHydro-Québec incentives\u003c\/h3\u003e\n\u003cp\u003eEligibility depends on the complete system. We check the official list based on the installation date, then tell you what applies to your project.\u003c\/p\u003e\n\n\u003ch3\u003eAn estimate before any decision\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFree on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e lets you spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402707693860,"sku":"EVD5X48S21B","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EVD5X_EVD5X48S21B_00_4_TONNES_48000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765872","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-evd5x48s21b-v-4-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}