{"product_id":"serpentin-devaporateur-comfortmaker-evm5x25m17a-v-2-tonnes","title":"COMFORTMAKER EVM5X25M17A Evaporator V-Coil | 2 Tons","description":"\u003ch2\u003eEVM5X25M17A: reading the AHRI sheet for a 2-ton Comfortmaker coil\u003c\/h2\u003e\n\u003cp\u003eWhen a quote mentions an \"EVM5X25M17A coil\", it refers to a specific part: a cased V-shaped evaporator coil from the \u003cstrong\u003eComfortmaker EVM5X\u003c\/strong\u003e series, rated at 2 tons (24,000 BTU\/h), using R-454B refrigerant. It measures 17-1\/2 × 19-7\/16 in. But the part on its own isn’t what matters for your comfort and your bill: it is the certified system it belongs to. This page explains how to read that system, using the real figures for the EVM5X25M17A.\u003c\/p\u003e\n\u003cp\u003eWe install this coil in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, on gas, oil or electric furnaces.\u003c\/p\u003e\n\n\u003ch3\u003eOne number that ties three parts together\u003c\/h3\u003e\n\u003cp\u003eAn AHRI number identifies a set: an outdoor unit, an indoor coil and, where needed, a blower. The published ratings (SEER2, HSPF2, capacities) apply only to that set. Change the coil and the figures change too.\u003c\/p\u003e\n\u003cp\u003eFor the EVM5X25M17A, Comfortmaker publishes two systems:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ewith \u003cstrong\u003eQ5H9V24*K*AAA\u003c\/strong\u003e: AHRI 217953876, cooling 23,400 BTU\/h, heating 24,600 BTU\/h at 47 °F, SEER2 16.0, HSPF2 8.5;\u003c\/li\u003e\n\u003cli\u003ewith \u003cstrong\u003eN5H9V24*K*AAA\u003c\/strong\u003e: AHRI 217953869, same capacities, SEER2 16.0 and HSPF2 8.5.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eKeep in mind the three things these lines tell you: the cooling capacity, the heating capacity at 47 °F, and the seasonal rating for each mode.\u003c\/p\u003e\n\n\u003ch3\u003eSEER2 and HSPF2: what are they for?\u003c\/h3\u003e\n\u003cp\u003eSEER2 measures cooling efficiency over a season, and HSPF2 does the same for a heat pump’s heating. The higher the rating, the less electricity the system uses to deliver the same warmth or the same cooling. For this model, the system shows SEER2 16.0, HSPF2 8.5.\u003c\/p\u003e\n\u003cp\u003eThese values come from laboratories and standardized conditions. In your home, the result also depends on how well the ducts are sealed, on the insulation and on how the system is set up at commissioning. That is why we take the time to check the airflow, and not just plug the units in.\u003c\/p\u003e\n\n\u003ch3\u003eHeating in the cold: what the manufacturer says\u003c\/h3\u003e\n\u003cp\u003eA heat pump loses capacity when the outdoor temperature drops. Comfortmaker publishes a heating capacity at -8.3 °C that ranges from 19,600 to 45,500 BTU\/h depending on the match. The EVM5X combinations with the Q5H9V and N5H9V units are ENERGY STAR certified for cold climates.\u003c\/p\u003e\n\u003cp\u003eThe furnace stays on as backup. It takes over below a temperature threshold that we set with you, based on the comfort you want and the energy rate you pay.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is inside the casing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eV-coil, multipoise: upflow, downflow or horizontal;\u003c\/li\u003e\n\u003cli\u003eTXV metering device, which regulates the refrigerant flow;\u003c\/li\u003e\n\u003cli\u003e3\/8 in (liquid) and 3\/4 in (suction) connections;\u003c\/li\u003e\n\u003cli\u003esloped PBT pan, 3 sealed plugs to choose the drain outlet;\u003c\/li\u003e\n\u003cli\u003enet weight of 35.7 lb;\u003c\/li\u003e\n\u003cli\u003eA2L leak sensor and complete dissipation system, factory-installed or supplied, per data sheet EVM5X-51-01PD;\u003c\/li\u003e\n\u003cli\u003e10-year limited parts warranty with registration within 90 days of installation, or 5 years without registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA height of 19-7\/16 in: a good middle size\u003c\/h3\u003e\n\u003cp\u003eThe EVM5X25M17A is taller than the lowest models in the series, without reaching the height of the largest. In practice, it needs a plenum with enough vertical clearance, and we measure for it during the visit. Many basement furnaces accommodate it without difficulty.\u003c\/p\u003e\n\u003cp\u003eIts 17-1\/2 in width is the same as that of several other models in the series. If the furnace is narrower or wider, we build a custom insulated transition.\u003c\/p\u003e\n\n\u003ch3\u003eChoosing between the EVM5X25M17A and its neighbours\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eEVM5X24M14A\u003c\/strong\u003e: 2 tons, narrower at 14-3\/16 in. It goes in small furnace cabinets.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVM5X24M17A\u003c\/strong\u003e: also 2 tons, 17-1\/2 in wide, with its own AHRI sheet.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVM5X30M17A, EVM5X31M17A, EVM5X32M17A\u003c\/strong\u003e: 2.5 tons, the same 17-1\/2 in width.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVM5X36M17A\u003c\/strong\u003e: 3 tons.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVM5X42M21A\u003c\/strong\u003e: 3.5 tons, 21 in, matched with B5H3V36*K*AAA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe refrigerant, the metering device and the Q5H9V24*K*AAA outdoor unit are common to most of them. To tell apart two models of the same capacity, we place their AHRI sheets side by side and see which one matches the height, the width and the ratings you are looking for.\u003c\/p\u003e\n\n\u003ch3\u003eAsking your installer the right questions\u003c\/h3\u003e\n\u003cp\u003eBefore you sign, ask: what is the AHRI number of the proposed system? Does the sheet really match this coil and this outdoor unit? Who checks the airflow at commissioning? A clear answer to these three questions says a lot about how seriously the work is done.\u003c\/p\u003e\n\u003cp\u003eAt AirGreen, we provide the quote in writing with the exact models, here the EVM5X25M17A and its outdoor unit. Nothing is left open to interpretation, and you can compare our offer with another one, line by line, using the AHRI number.\u003c\/p\u003e\n\u003cp\u003eWe also explain, in plain terms, what the system will do in your home: which rooms will be best served, where the air will come out, and what you will hear, or won’t hear, at start-up.\u003c\/p\u003e\n\u003ch3\u003eWhat this coil does not do\u003c\/h3\u003e\n\u003cp\u003eIt produces neither cooling nor heat by itself: it exchanges heat with the air passing through it. It does not replace a blower, does not fix poorly sealed ducts and cannot be matched with an old outdoor unit. Because it runs on R-454B, the outdoor unit must use the same refrigerant and be installed at the same time.\u003c\/p\u003e\n\n\u003ch2\u003eThe AirGreen installation, from measuring to start-up\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under our RBQ licence 5645-9605-01. Here is how it goes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum, building a transition if needed, sealed duct connections;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit on a pad or bracket, brazed piping, nitrogen leak test, evacuation;\u003c\/li\u003e\n\u003cli\u003econdensate drain and thermostat connected;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and explanations on site.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat to check before choosing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSame refrigerant (R-454B) for the coil and the outdoor unit.\u003c\/li\u003e\n\u003cli\u003eRatings valid for the certified match only.\u003c\/li\u003e\n\u003cli\u003eFurnace width and blower capacity, confirmed during the visit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert grant\u003c\/h3\u003e\n\u003cp\u003eThe matched Comfortmaker system is on Hydro-Québec’s list of eligible heat pumps. The amount varies with the installation date and your situation: we check it on the official list when we prepare the quote and help you put the application together.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402707104036,"sku":"EVM5X25M17A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EVM5X_EVM5X25M17A_00_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765873","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-evm5x25m17a-v-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}