{"product_id":"serpentin-devaporateur-comfortmaker-evm5x30m17a-v-2-5-tonnes","title":"COMFORTMAKER EVM5X30M17A Evaporator V-Coil | 2.5 Tons","description":"\u003ch2\u003eEVM5X30M17A, a 2.5-ton coil that works all year round\u003c\/h2\u003e\n\u003cp\u003ePeople often talk about a coil as a summer part. Yet the \u003cstrong\u003eComfortmaker EVM5X30M17A\u003c\/strong\u003e, a cased V-shaped evaporator coil rated at 2.5 tons (30,000 BTU\/h) and using R-454B refrigerant, plays a role in every season when it is matched with a heat pump. Here is what a year with this model looks like in a home in our region: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e or the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eJuly: cool, dry air in every room\u003c\/h3\u003e\n\u003cp\u003eWhen the outdoor unit starts, the refrigerant arrives cold at the coil installed in the furnace plenum. The blower pushes the house air through the two faces of the V. The air loses its heat and some of its moisture, the water runs into the sloped pan and out to the drain. The same ducts that served in winter now distribute cool air, with no window unit and no noise in the bedroom.\u003c\/p\u003e\n\u003cp\u003eThe 2.5-ton size serves a mid-sized home well, for example a larger bungalow or a compact two-storey house. We always confirm the load before promising anything.\u003c\/p\u003e\n\n\u003ch3\u003eOctober: the shoulder season\u003c\/h3\u003e\n\u003cp\u003eDays that are cool but not cold are a heat pump’s home ground. The outdoor unit draws heat from the outside air and transfers it, through the coil, to the air in the house. The direction of the cycle reverses, but the path of the air stays the same. The furnace itself doesn’t start up.\u003c\/p\u003e\n\n\u003ch3\u003eJanuary: the furnace as backup\u003c\/h3\u003e\n\u003cp\u003eWhen the cold sets in, the heat pump delivers less heat. Comfortmaker lists a heating capacity at -8.3 °C of 19,600 to 45,500 BTU\/h depending on the match. Below a threshold that we set with you, the furnace takes over with its blower, its filters and its heating elements. That way you benefit from the heat pump for most of the season, and keep the furnace for the harshest nights.\u003c\/p\u003e\n\n\u003ch3\u003eThe certified system around the EVM5X30M17A\u003c\/h3\u003e\n\u003cp\u003eThe coil has no efficiency rating of its own. The figures belong to the set defined by an AHRI number. For this model, Comfortmaker publishes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eQ5H9V24*K*AAA\u003c\/strong\u003e outdoor unit, AHRI 217953892: cooling 23,400 BTU\/h, heating 24,600 BTU\/h at 47 °F, SEER2 16.0, HSPF2 8.5;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eN5H9V24*K*AAA\u003c\/strong\u003e outdoor unit, AHRI 217953885: same capacities and same ratings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese variable-speed heat pumps belong to Comfortmaker’s QuietComfort \/ Performance 19 SEER2 family, using R-454B. The EVM5X matches with Q5H9V and N5H9V are ENERGY STAR certified for cold climates. With a heat pump, the outdoor unit must have a piston metering device in heating.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the data sheet says\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003edimensions W × H × D: 17-1\/2 × 19-7\/16 in;\u003c\/li\u003e\n\u003cli\u003enet weight: 35.7 lb;\u003c\/li\u003e\n\u003cli\u003e3\/8 in liquid connection, 3\/4 in suction connection;\u003c\/li\u003e\n\u003cli\u003edrain: sloped PBT pan and 3 sealed plugs;\u003c\/li\u003e\n\u003cli\u003eTXV metering device;\u003c\/li\u003e\n\u003cli\u003emultipoise, so upflow, downflow or horizontal;\u003c\/li\u003e\n\u003cli\u003eA2L leak sensor and complete dissipation system, factory-installed or supplied (data sheet EVM5X-51-01PD);\u003c\/li\u003e\n\u003cli\u003e10-year limited parts warranty with registration within 90 days of installation, 5 years without registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOne of three 2.5-ton models\u003c\/h3\u003e\n\u003cp\u003eThe series offers three 2.5-ton coils: the EVM5X30M17A, the EVM5X31M17A and the EVM5X32M17A. All three are 17-1\/2 in wide and use R-454B and the TXV metering device. They differ in casing height, weight, AHRI number and system ratings. The EVM5X32M17A, for example, is also matched with a B5H0V24*K*AAA unit.\u003c\/p\u003e\n\u003cp\u003eOur approach is simple: we measure the clearance above the furnace, then go over the three data sheets with you. If space is limited, the choice is quick; if there is plenty of room, we compare the published ratings for each match.\u003c\/p\u003e\n\n\u003ch3\u003eAnd if the house needs more or less?\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eEVM5X24M14A, EVM5X24M17A, EVM5X25M17A\u003c\/strong\u003e: 2 tons, for smaller homes. The first is the narrowest, at 14-3\/16 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVM5X36M17A\u003c\/strong\u003e: 3 tons, at 17-1\/2 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVM5X42M21A\u003c\/strong\u003e: 3.5 tons, at 21 in, with a B5H3V36*K*AAA unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApril and November: the seasonal changeovers\u003c\/h3\u003e\n\u003cp\u003eThese are the times when the thermostat hesitates between heating and cooling. With a matched system, a single control is enough: the thermostat picks the mode, and the coil follows. There is no filter swap or valve to handle. For a homeowner, that is one less task in the year and a house that stays comfortable without supervision.\u003c\/p\u003e\n\u003cp\u003eIt is also a good time to think about maintenance. We advise keeping the furnace filters clean, since the blower is what pushes the air through the coil; a clogged filter reduces airflow and strains the system.\u003c\/p\u003e\n\u003cp\u003eFinally, make sure the condensate drain stays clear. We show you where it is at commissioning, so you know what to look at at the start of summer.\u003c\/p\u003e\n\u003ch3\u003eThe mistakes we see too often\u003c\/h3\u003e\n\u003cp\u003eFirst, choosing a size that is too big \"to be safe\". Excess capacity makes the system run in short bursts and leaves moisture in the air. Second, believing that an old outdoor unit can be connected to a new coil. R-454B doesn’t mix with the old refrigerant, and the two components must be matched. Third, forgetting to check the blower: it is the blower that has to deliver the system’s airflow.\u003c\/p\u003e\n\n\u003ch2\u003eOur installation service in Greater Montreal\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is carried out under our RBQ licence 5645-9605-01. For this coil and its outdoor unit, we plan for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace and checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum, with a custom transition if the width requires it, and sealed duct connections;\u003c\/li\u003e\n\u003cli\u003einstalling the outdoor unit, brazed piping, nitrogen test and evacuation;\u003c\/li\u003e\n\u003cli\u003econnecting the drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and an explanation of how the system works.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat to check before ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-454B requires an outdoor unit with the same refrigerant, installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe ratings apply to the certified match, not to the coil alone.\u003c\/li\u003e\n\u003cli\u003eThe furnace must have the right width and blower; we confirm this at your home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert grant\u003c\/h3\u003e\n\u003cp\u003eThe matched Comfortmaker system is listed on Hydro-Québec’s list of eligible heat pumps. The amount depends on the installation date and your situation. We confirm it on the official list at the time of the quote and put the application together with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402708185380,"sku":"EVM5X30M17A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EVM5X_EVM5X30M17A_00_2_5_TONNES_30000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765880","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-evm5x30m17a-v-2-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}