{"product_id":"serpentin-devaporateur-comfortmaker-evm5x31m17a-v-2-5-tonnes","title":"COMFORTMAKER EVM5X31M17A Evaporator V-Coil | 2.5 Tons","description":"\u003ch2\u003eThe EVM5X31M17A from the mechanical room: a tall 2.5-ton casing\u003c\/h2\u003e\n\u003cp\u003eOn paper, the \u003cstrong\u003eComfortmaker EVM5X31M17A evaporator coil\u003c\/strong\u003e comes down to one line: cased V-coil, 2.5 tons (30,000 BTU\/h), R-454B refrigerant, 17-1\/2 in wide. In a mechanical room, it is something else. This model is 25-13\/16 in tall and weighs 42.3 lb: it is a casing you see, lift and have to find room for. Here is what we look at in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e before proposing it.\u003c\/p\u003e\n\n\u003ch3\u003eFirst check: vertical clearance\u003c\/h3\u003e\n\u003cp\u003eAt 25-13\/16 in tall, the EVM5X31M17A needs room between the top of the furnace and the ceiling or the start of the ducts. We measure from the furnace’s air outlet, taking into account the existing sheet metal, the supports and whatever will need to be recut. In a basement with an unfinished ceiling, this is usually simple. Under a dropped ceiling or in a closed cabinet, we would rather know before delivery.\u003c\/p\u003e\n\u003cp\u003eIf space is too tight, another coil from the same series can solve the problem. We say so right away, rather than forcing an installation.\u003c\/p\u003e\n\n\u003ch3\u003eSecond check: weight and access\u003c\/h3\u003e\n\u003cp\u003eAt 42.3 lb, the casing is still manageable, but it has to be carried down a narrow staircase without bumping the walls. Two technicians take care of it, and the work is done with protection in place: we cover the floor and the steps. The 17-1\/2 in width is no problem for getting through a standard basement door.\u003c\/p\u003e\n\n\u003ch3\u003eThird check: the furnace width\u003c\/h3\u003e\n\u003cp\u003eThe 17-1\/2 in wide casing has to connect to the furnace’s air outlet. When the furnace has a different size, we build an insulated transition. It is a routine job, which we do on site with sheet metal and insulation, rather than ordering a standard part that doesn’t fit.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the certified ratings promise\u003c\/h3\u003e\n\u003cp\u003eA coil has no efficiency rating on its own. Here are the systems published by Comfortmaker with the EVM5X31M17A:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eQ5H9V24*K*AAA\u003c\/strong\u003e: AHRI 217953908, cooling 23,800 BTU\/h, heating 25,000 BTU\/h at 47 °F, SEER2 16.5, HSPF2 8.5;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eN5H9V24*K*AAA\u003c\/strong\u003e: AHRI 217953901, same capacities, SEER2 16.5 and HSPF2 8.5.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe SEER2 16.5 rating belongs to this specific system, not to a promise attached to the coil. If you replace the outdoor unit or the coil, the ratings change and you need to consult the sheet for the new match.\u003c\/p\u003e\n\u003cp\u003eThe Q5H9V and N5H9V units belong to Comfortmaker’s variable-speed QuietComfort \/ Performance 19 SEER2 line, using R-454B. The manufacturer describes them as ENERGY STAR certified for cold climates with the EVM5X, and publishes a heating capacity at -8.3 °C of 19,600 to 45,500 BTU\/h depending on the match.\u003c\/p\u003e\n\n\u003ch3\u003eList of features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emodel EVM5X31M17A, cased coil, EVM5X series;\u003c\/li\u003e\n\u003cli\u003e2.5 tons, 30,000 BTU\/h nominal;\u003c\/li\u003e\n\u003cli\u003edimensions W × H × D: 17-1\/2 × 25-13\/16 in; net weight: 42.3 lb;\u003c\/li\u003e\n\u003cli\u003e3\/8 in liquid connection, 3\/4 in suction;\u003c\/li\u003e\n\u003cli\u003esloped PBT pan with 3 sealed plugs;\u003c\/li\u003e\n\u003cli\u003eTXV metering device; multipoise (upflow, downflow, horizontal);\u003c\/li\u003e\n\u003cli\u003eA2L leak sensor and complete dissipation, factory-installed or supplied (data sheet EVM5X-51-01PD);\u003c\/li\u003e\n\u003cli\u003e10-year limited parts warranty with registration within 90 days of installation, 5 years without registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePlanning installation day\u003c\/h3\u003e\n\u003cp\u003eA casing this size takes some preparation. Before the crew arrives, we clear access to the furnace with you: boxes, shelves and sometimes a dryer get moved. We also ask you to plan a spot for the condensate drain, either a floor drain nearby or a pump, which we assess during the visit.\u003c\/p\u003e\n\u003cp\u003eIn the morning, we install the casing and connect the refrigerant piping. By early afternoon, the outdoor unit is in place, and the pipes are brazed and pressurized with nitrogen to check for leaks. Evacuation comes next, then commissioning and airflow adjustment. Before leaving, we show you how the thermostat works and where each component is located.\u003c\/p\u003e\n\u003cp\u003eIf your furnace doesn’t have the right width, that day includes building the transition. We never leave a casing sitting on a poorly fitted opening: hot or cold air would escape through the joints and the system’s efficiency would suffer.\u003c\/p\u003e\n\u003cp\u003eFinally, we clean up after ourselves. Sheet-metal offcuts, packaging and tools leave the house with us.\u003c\/p\u003e\n\u003ch3\u003eHeating: from electric to a heat pump\u003c\/h3\u003e\n\u003cp\u003eMany of our customers heat today with an electric furnace. Adding a heat pump changes the logic: instead of turning each kilowatt-hour into an equal amount of heat, the heat pump moves heat from outside to inside and delivers more than the electricity it consumes, especially in mild weather. The colder it gets, the less the unit delivers, which is why the furnace stays on as backup.\u003c\/p\u003e\n\u003cp\u003eThe coil is the surface through which heat enters the air in the house. In summer, it does the opposite job and removes heat and moisture.\u003c\/p\u003e\n\n\u003ch3\u003eHow does it fit in the series?\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eEVM5X30M17A\u003c\/strong\u003e and \u003cstrong\u003eEVM5X32M17A\u003c\/strong\u003e: the same 2.5-ton capacity and the same 17-1\/2 in width. What changes: the casing and the AHRI sheet. The EVM5X32M17A adds a match with the B5H0V24*K*AAA unit.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVM5X24M14A, EVM5X24M17A, EVM5X25M17A\u003c\/strong\u003e: 2 tons. The first is narrow, at 14-3\/16 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVM5X36M17A\u003c\/strong\u003e: 3 tons.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVM5X42M21A\u003c\/strong\u003e: 3.5 tons, 21 in wide, with a B5H3V36*K*AAA unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTXV metering device and R-454B everywhere: neither helps you tell them apart. Count instead on the available space and on the ratings sheet.\u003c\/p\u003e\n\n\u003ch3\u003eWhat doesn’t change with a tall model\u003c\/h3\u003e\n\u003cp\u003eThe furnace keeps its blower, its filters and its heating elements. The ducts stay the same. The thermostat controls the whole system. The only real difference is seen above the furnace, where a taller casing takes its place.\u003c\/p\u003e\n\n\u003ch2\u003eThe AirGreen job, step by step\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under our RBQ licence 5645-9605-01. For this coil:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the clearance and the furnace, checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum, custom transition if needed, sealed duct connections;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit on a pad or bracket, brazed piping, nitrogen test and evacuation;\u003c\/li\u003e\n\u003cli\u003econdensate drain and thermostat connected;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and explanation of how the system works.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat to check before choosing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe outdoor unit must use R-454B, like the coil, and be installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply to the certified match.\u003c\/li\u003e\n\u003cli\u003eThe furnace width, the clearance and the blower are confirmed during the visit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert grant\u003c\/h3\u003e\n\u003cp\u003eThe matched Comfortmaker system is on Hydro-Québec’s list of eligible heat pumps. The amount depends on the installation date and your situation. We check the official list when we prepare the quote and put the application together with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402708873508,"sku":"EVM5X31M17A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EVM5X_EVM5X31M17A_00_2_5_TONNES_30000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765881","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-evm5x31m17a-v-2-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}