{"product_id":"serpentin-devaporateur-comfortmaker-evm5x32m17a-v-2-5-tonnes","title":"COMFORTMAKER EVM5X32M17A Evaporator V-Coil | 2.5 Tons","description":"\u003ch2\u003eThree outdoor units, one coil: the 2.5-ton EVM5X32M17A\u003c\/h2\u003e\n\u003cp\u003eMost coils in the Comfortmaker EVM5X series are matched with two outdoor units. The \u003cstrong\u003eEVM5X32M17A\u003c\/strong\u003e, a cased V-shaped evaporator coil rated at 2.5 tons (30,000 BTU\/h) and using R-454B refrigerant, accepts three. This page is therefore mostly here to answer the real question it raises: which of these three units should you choose for your home in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e or on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e?\u003c\/p\u003e\n\n\u003ch3\u003eThe three certified systems\u003c\/h3\u003e\n\u003cp\u003eEach match has its own AHRI number and its own ratings. Here is what Comfortmaker publishes for this coil:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eQ5H9V24*K*AAA\u003c\/strong\u003e: AHRI 217953924, cooling 24,000 BTU\/h, heating 25,200 BTU\/h at 47 °F, SEER2 17.0, HSPF2 8.5;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eN5H9V24*K*AAA\u003c\/strong\u003e: AHRI 217953917, same capacities and same ratings as the previous one;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eB5H0V24*K*AAA\u003c\/strong\u003e: AHRI 218169644, cooling 24,400 BTU\/h, heating 27,800 BTU\/h at 47 °F, SEER2 19.0, HSPF2 8.5.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTwo things stand out. First, the third unit shows SEER2 19.0 and a higher heating capacity at 47 °F. Second, all three share the same seasonal heating rating, HSPF2 8.5. The gain is therefore mostly on the cooling side and in heating capacity in mild weather.\u003c\/p\u003e\n\n\u003ch3\u003eQuietComfort or SoftSound?\u003c\/h3\u003e\n\u003cp\u003eThe Q5H9V and N5H9V units belong to Comfortmaker’s QuietComfort \/ Performance 19 SEER2 line. The B5H0V unit is part of the SoftSound 20 \/ 23 line. All are variable-speed heat pumps and run on R-454B. The manufacturer states that the matches with Q5H9V and N5H9V are ENERGY STAR certified for cold climates, and that heating capacity at -8.3 °C ranges from 19,600 to 45,500 BTU\/h depending on the match.\u003c\/p\u003e\n\u003cp\u003eOur advice is simple. If the budget is tight and the house is mid-sized, the Q5H9V or N5H9V pair meets most needs. If you want the highest rating in the table, the match with B5H0V24*K*AAA shows the highest SEER2 for this coil. We lay the quotes side by side so you can see the price difference against the difference in ratings.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the SEER2 rating will change on your bill\u003c\/h3\u003e\n\u003cp\u003eA higher SEER2 rating means less electricity used for the same cooling. But the saving depends on your habits: if you cool the house on only a few days each summer, the difference is measured in very few kilowatt-hours. If you keep the house cool from June to September, it becomes more noticeable. It is a calculation to do with your real consumption, and we help you do it.\u003c\/p\u003e\n\n\u003ch3\u003eA question of noise and comfort\u003c\/h3\u003e\n\u003cp\u003eA variable-speed heat pump adjusts its speed to the load instead of starting and stopping. The result: the temperature of the air delivered varies less, and the outdoor unit makes less noise when it runs slowly. The SoftSound line is named for that very reason. If your patio or a bedroom window is close to the unit, this detail weighs in the decision.\u003c\/p\u003e\n\u003cp\u003eWe choose the location of the outdoor unit with you: at a good distance from bedroom windows, away from places where snow piles up, with enough clearance for airflow and servicing.\u003c\/p\u003e\n\u003cp\u003eTo decide between the three matches, we proceed like this: a walk through the house to estimate the load, a look at your electricity bill, then a written quote for each option you keep, with the AHRI number of each. You then compare a price against a ratings sheet, instead of comparing promises.\u003c\/p\u003e\n\u003ch3\u003eThe casing: large and heavy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003edimensions W × H × D: 17-1\/2 × 29-3\/4 in;\u003c\/li\u003e\n\u003cli\u003enet weight: 47.1 lb;\u003c\/li\u003e\n\u003cli\u003e3\/8 in liquid connection, 3\/4 in suction connection;\u003c\/li\u003e\n\u003cli\u003esloped PBT pan, 3 sealed plugs;\u003c\/li\u003e\n\u003cli\u003eTXV metering device;\u003c\/li\u003e\n\u003cli\u003emultipoise: upflow, downflow, horizontal;\u003c\/li\u003e\n\u003cli\u003eA2L leak sensor and complete dissipation system, factory-installed or supplied (data sheet EVM5X-51-01PD);\u003c\/li\u003e\n\u003cli\u003e10-year limited parts warranty with registration within 90 days of installation, 5 years without registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAt 29-3\/4 in tall, this casing needs a generous plenum. We measure the free space above the furnace before proposing this model. If the clearance is limited, another 2.5-ton coil from the same series may suit.\u003c\/p\u003e\n\n\u003ch3\u003eThe casing, the furnace, the blower\u003c\/h3\u003e\n\u003cp\u003eThe coil adds resistance to the passage of air, and the blower has to overcome it while delivering the intended airflow. We therefore check the motor, the selected speed and the condition of the filter. A tall casing offers surface area, but it doesn’t make up for a blower that is too weak or return ducts that are undersized.\u003c\/p\u003e\n\n\u003ch3\u003eWhere does it fit in the series?\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eEVM5X30M17A\u003c\/strong\u003e and \u003cstrong\u003eEVM5X31M17A\u003c\/strong\u003e: the same 2.5-ton size and the same 17-1\/2 in width, but a shorter casing and different ratings. Only the EVM5X32M17A offers the B5H0V option.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e2-ton models\u003c\/strong\u003e (EVM5X24M14A, EVM5X24M17A, EVM5X25M17A): for smaller homes; the EVM5X24M14A is the narrowest, at 14-3\/16 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVM5X36M17A\u003c\/strong\u003e: 3 tons, 17-1\/2 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVM5X42M21A\u003c\/strong\u003e: 3.5 tons, 21 in, with B5H3V36*K*AAA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe \"add-on\" heat pump in a few words\u003c\/h3\u003e\n\u003cp\u003eThe furnace keeps its blower, its filters and its heating elements. The coil is installed in the plenum. In summer, it cools and dries the air; in winter, with a heat pump, it releases the heat captured outside into the air. The furnace takes over below the temperature threshold that we set with you.\u003c\/p\u003e\n\n\u003ch2\u003eOur installation in Greater Montreal\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under our RBQ licence 5645-9605-01. For this coil and the outdoor unit you choose:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace and the clearance, checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum, transition if needed, sealed duct connections;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit on a pad or bracket, brazed piping, nitrogen test and evacuation;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and demonstration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat to check before choosing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil and the outdoor unit use R-454B and are installed together.\u003c\/li\u003e\n\u003cli\u003eThe ratings apply only to the specific match you choose.\u003c\/li\u003e\n\u003cli\u003eThe furnace must have the right width and blower; we confirm this during the visit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert grant\u003c\/h3\u003e\n\u003cp\u003eThe matched Comfortmaker system is on Hydro-Québec’s list of eligible heat pumps. The amount depends on the installation date and your situation. We check it on the official list when we prepare the quote, then put the application together with you. The result may vary depending on the outdoor unit you choose.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402711920932,"sku":"EVM5X32M17A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EVM5X_EVM5X32M17A_00_2_5_TONNES_30000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765879","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-evm5x32m17a-v-2-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}