{"product_id":"serpentin-devaporateur-comfortmaker-evm5x36m17a-v-3-tonnes","title":"COMFORTMAKER EVM5X36M17A Evaporator V-Coil | 3 Tons","description":"\u003ch2\u003eEVM5X36M17A: your questions about the 3-ton Comfortmaker coil\u003c\/h2\u003e\n\u003cp\u003eHomeowners looking at the \u003cstrong\u003eComfortmaker EVM5X36M17A evaporator coil\u003c\/strong\u003e almost always ask the same questions. We answer them here, one by one, using the data published by the manufacturer. It is a cased V-shaped coil rated at 3 tons (36,000 BTU\/h), using R-454B refrigerant, that sits on a furnace or a blower cabinet. We install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eIs it the right size for my home?\u003c\/h3\u003e\n\u003cp\u003eThree tons suits a large share of the bungalows and two-storey homes in the region: furnace in the basement, ducts to every room, and often an old central air conditioner or window units. But the size can’t be guessed from floor area alone. Insulation, orientation, windows and the number of occupants all count. We do a load calculation before recommending anything, and we tell you whether a smaller or larger size would serve you better.\u003c\/p\u003e\n\n\u003ch3\u003eCan my old central air conditioner stay?\u003c\/h3\u003e\n\u003cp\u003eGenerally, no. This coil runs on R-454B, while the old equipment uses a different refrigerant. It has to be matched with the outdoor unit specified by the manufacturer, and the two components are installed together.\u003c\/p\u003e\n\n\u003ch3\u003eDoes it heat too?\u003c\/h3\u003e\n\u003cp\u003eYes, if the outdoor unit is a heat pump. In that case, the coil cools in summer and heats in winter, using the existing ducts. With a central air conditioner, it is used only for cooling. The furnace stays in place, with its blower and its filters, and serves as backup heating for the coldest nights.\u003c\/p\u003e\n\n\u003ch3\u003eWhat are the system ratings?\u003c\/h3\u003e\n\u003cp\u003eThe coil has none on its own: they belong to the certified system. For the EVM5X36M17A, Comfortmaker publishes two matches:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eQ5H9V24*K*AAA\u003c\/strong\u003e: AHRI 217953940, cooling 23,400 BTU\/h, heating 24,600 BTU\/h at 47 °F, SEER2 16.0, HSPF2 8.5;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eN5H9V24*K*AAA\u003c\/strong\u003e: AHRI 217953933, same capacities and same ratings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese units are variable-speed heat pumps from the QuietComfort \/ Performance 19 SEER2 line, using R-454B. Comfortmaker lists EVM5X matches with Q5H9V or N5H9V that are ENERGY STAR certified for cold climates, and a heating capacity at -8.3 °C of 19,600 to 45,500 BTU\/h depending on the match.\u003c\/p\u003e\n\u003cp\u003eWhen you compare two quotes, ask for the AHRI number of each. It is the most reliable way to know whether they describe the same system.\u003c\/p\u003e\n\n\u003ch3\u003eIs it the same size as the others in the series?\u003c\/h3\u003e\n\u003cp\u003eNo. The EVM5X36M17A measures 17-1\/2 × 19-7\/16 in and weighs 35.7 lb. Its 17-1\/2 in width is shared by most models in the series; the difference between them comes down to nominal capacity and casing height.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if my furnace isn’t that width?\u003c\/h3\u003e\n\u003cp\u003eWe measure and, if needed, build an insulated transition on site. It is a common and clean solution: there is no risk of air escaping when the joints are properly sealed.\u003c\/p\u003e\n\n\u003ch3\u003eWhat exactly is in the casing?\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ea multipoise V-coil: upflow, downflow or horizontal;\u003c\/li\u003e\n\u003cli\u003ea TXV metering device;\u003c\/li\u003e\n\u003cli\u003e3\/8 in (liquid) and 3\/4 in (suction) connections;\u003c\/li\u003e\n\u003cli\u003ea sloped PBT pan with 3 sealed plugs;\u003c\/li\u003e\n\u003cli\u003ean A2L leak sensor and a complete dissipation system, factory-installed or supplied (data sheet EVM5X-51-01PD);\u003c\/li\u003e\n\u003cli\u003ea 10-year limited parts warranty with registration within 90 days of installation, or 5 years without registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShould I choose it over another model?\u003c\/h3\u003e\n\u003cp\u003eLet’s compare it with its neighbours in the series, using only the published data sheets.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eEVM5X30M17A, EVM5X31M17A, EVM5X32M17A\u003c\/strong\u003e: 2.5 tons, the same 17-1\/2 in width. If the house needs less capacity, one of these models may be enough.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVM5X24M14A, EVM5X24M17A, EVM5X25M17A\u003c\/strong\u003e: 2 tons, for small homes and plex units. The EVM5X24M14A is the narrowest, at 14-3\/16 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVM5X42M21A\u003c\/strong\u003e: 3.5 tons at 21 in, with a B5H3V36*K*AAA unit; it is meant for a larger house or a wider furnace.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe EVM5X36M17A therefore sits in the middle of the series by capacity, and it relies on the same outdoor unit as the smaller models.\u003c\/p\u003e\n\n\u003ch3\u003eHow long does the work take?\u003c\/h3\u003e\n\u003cp\u003eWe do it in a single installation visit planned in advance. We measure the furnace, install the coil, install the outdoor unit, braze the piping, run the nitrogen test and evacuation, then connect the drain and the thermostat. Commissioning and airflow adjustment finish the job. The exact timing depends on the layout of the house; we spell it out in the quote.\u003c\/p\u003e\n\n\u003ch3\u003eWhat about maintenance after installation?\u003c\/h3\u003e\n\u003cp\u003eNot much, but it counts. Change the furnace filter regularly: a clogged filter reduces the airflow through the coil, and the system works harder for a lesser result. Keep the return grilles clear, with no furniture or rugs blocking them. In spring, take a look at the condensate drain to make sure water flows freely.\u003c\/p\u003e\n\u003cp\u003eAlso remember to register the product: the 10-year limited parts warranty requires registration within 90 days of installation, otherwise it drops to 5 years. We remind you of this step at the end of the job and can help you do it.\u003c\/p\u003e\n\u003cp\u003eFinally, plan to have a technician check the system from time to time. A clean coil, sealed piping and the correct refrigerant charge are the three conditions for stable operation, season after season.\u003c\/p\u003e\n\u003ch3\u003eWhy does the blower matter?\u003c\/h3\u003e\n\u003cp\u003eThe furnace blower has to deliver the system’s airflow. With a 3-ton size, the demand for air is greater than with a small model. We therefore check the motor, the speed setting, the filter and the condition of the return air paths. A well-chosen coil doesn’t make up for a choked duct system.\u003c\/p\u003e\n\n\u003ch2\u003eOur installation in Greater Montreal\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under our RBQ licence 5645-9605-01. For this coil and its outdoor unit:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum, custom transition if needed, sealed duct connections;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit on a pad or bracket, brazed piping, nitrogen leak test, evacuation;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and explanations at your home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat to check before choosing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-454B requires an outdoor unit with the same refrigerant, installed along with the coil.\u003c\/li\u003e\n\u003cli\u003eThe ratings apply to the certified match.\u003c\/li\u003e\n\u003cli\u003eThe furnace width and blower must be suitable; we confirm this at the visit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert grant\u003c\/h3\u003e\n\u003cp\u003eThe matched Comfortmaker system is on Hydro-Québec’s list of eligible heat pumps. The amount depends on the installation date and your situation. We check the official list when we prepare the quote and put the application together with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402714312996,"sku":"EVM5X36M17A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EVM5X_EVM5X36M17A_00_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765881","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-evm5x36m17a-v-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}