{"product_id":"serpentin-devaporateur-comfortmaker-evm5x49m21a-v-4-tonnes","title":"COMFORTMAKER EVM5X49M21A Evaporator V-Coil | 4 Tons","description":"\u003ch2\u003eEVM5X49M21A: 4 tons, ENERGY STAR cold-climate match with the Q5H9V48*K*AAA\u003c\/h2\u003e\n\u003cp\u003eIn Quebec, the real test of a heat pump does not come in July, but in January. That is what makes the \u003cstrong\u003eComfortmaker EVM5X49M21A evaporator coil\u003c\/strong\u003e interesting: among the seven EVM5X models on this page, it is one whose main outdoor unit, the \u003cstrong\u003eQ5H9V48*K*AAA\u003c\/strong\u003e, is part of the matches that Comfortmaker states are certified ENERGY STAR cold climate.\u003c\/p\u003e\n\u003cp\u003eIt is a cased 4-ton (48,000 BTU\/h) V-coil using R-454B refrigerant, which we install on furnaces in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhat \"cold climate\" means for your bill\u003c\/h3\u003e\n\u003cp\u003eA heat pump loses capacity as the outdoor temperature drops. Models designed for the cold limit that loss. For the matched range, Comfortmaker lists a heating capacity at -8.3 °C that runs from 19,600 to 45,500 BTU\/h depending on the match. The exact value depends on the outdoor unit chosen; we go over it with you before you sign.\u003c\/p\u003e\n\u003cp\u003eIn practical terms, the more capacity the heat pump keeps in cold weather, the less often the furnace has to take over. It stays there for the cold peaks, and it is the changeover threshold, programmed with you, that decides when.\u003c\/p\u003e\n\n\u003ch3\u003eThe three published matches\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQ5H9V48*K*AAA, AHRI 217954486: cooling 47,000 BTU\/h, heating 52,000 BTU\/h at 47 °F, SEER2 15.2, HSPF2 9.0;\u003c\/li\u003e\n\u003cli\u003eN5H9V48*K*AAA, AHRI 217954481: cooling 47,000 BTU\/h, heating 52,000 BTU\/h at 47 °F, SEER2 15.2, HSPF2 9.0;\u003c\/li\u003e\n\u003cli\u003eC5H8T48*K*AAA, AHRI 216349393: cooling 48,000 BTU\/h, heating 50,000 BTU\/h at 47 °F, SEER2 16.5, HSPF2 7.8.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe first two are variable-speed heat pumps from the QuietComfort and Performance 19 SEER2 series. The last is a model from the C5H8T family. In all three cases, the AHRI number identifies the complete system: the coil has no efficiency rating of its own.\u003c\/p\u003e\n\u003cp\u003eNote the difference between the figures: the last match shows a higher SEER2 but a lower HSPF2. For a home that heats more than it cools, HSPF2 is the figure to look at first.\u003c\/p\u003e\n\n\u003ch3\u003eWhich model to choose in the series?\u003c\/h3\u003e\n\u003cp\u003eLet us compare the EVM5X49M21A with its six neighbours:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eEVM5X48M21A\u003c\/strong\u003e: same 4-ton size, same width, but the main outdoor unit is the B5H0V48*K*AAA, and the cabinet is shorter. It suits better when height is lacking.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVM5X43M21A\u003c\/strong\u003e and \u003cstrong\u003eEVM5X44M21A\u003c\/strong\u003e: 3.5 tons, also 21 in, with the B5H3V36*K*AAA. Worth keeping in mind if the home's load is more modest.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVM5X60M21A\u003c\/strong\u003e: 5 tons, 21 in, same main outdoor unit as the 49M21A. If the house grows or the load is high, it is the next step up.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVM5X60M24A\u003c\/strong\u003e and \u003cstrong\u003eEVM5X61M24A\u003c\/strong\u003e: 5 tons, wider (24-1\/2 in), for wide furnaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 49M21A is therefore the right choice for a 4-ton home with a furnace 21 in wide, where you want a heat pump designed for winter.\u003c\/p\u003e\n\n\u003ch3\u003eA cabinet 29-3\/4 in high\u003c\/h3\u003e\n\u003cp\u003ePublished dimensions: 21 × 29-3\/4 in, with a net weight of 49.6 lb. The cabinet is taller than those of the EVM5X43M21A and EVM5X48M21A, which calls for a roomy plenum. We measure before ordering; if the height is borderline, we say so plainly and propose the shortest model that fits.\u003c\/p\u003e\n\n\u003ch3\u003eHow the coil fits into a heat pump\u003c\/h3\u003e\n\u003cp\u003eIn cooling, the refrigerant evaporates in the coil tubes and absorbs heat from the air in the house. In heating, the cycle is reversed: the refrigerant, warmed by the outdoor unit, releases its heat to the air passing through the coil. One important technical point: with a heat pump, the outdoor unit must have a piston expansion device in heating mode. The coil itself uses a TXV.\u003c\/p\u003e\n\u003cp\u003eThe condensate pan, in sloped PBT and fitted with three sealed plugs, carries away the water produced in cooling. The connections are 3\/8 in (liquid) and 7\/8 in (suction).\u003c\/p\u003e\n\n\u003ch3\u003eEVM5X49M21A sheet\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003erange: EVM5X, Comfortmaker;\u003c\/li\u003e\n\u003cli\u003etype: cased evaporator coil;\u003c\/li\u003e\n\u003cli\u003enominal size: 4 tons (48,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003epositions: upflow, downflow or horizontal;\u003c\/li\u003e\n\u003cli\u003eleak detection: A2L sensor and complete dissipation system supplied or installed at the factory (sheet EVM5X-51-01PD);\u003c\/li\u003e\n\u003cli\u003emanufacturer warranty: 10 years on parts with registration within 90 days of installation, 5 years without registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOur assessment visit\u003c\/h3\u003e\n\u003cp\u003eBefore proposing this system, we review the blower, the plenum and the return air. A 4-ton coil requires high airflow; if the furnace cannot supply it, we explain why and propose solutions. If the furnace width differs from 21 in, an insulated transition is built on site.\u003c\/p\u003e\n\n\u003ch3\u003eHow the work unfolds\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company that has worked in Montreal for more than fifteen years, under RBQ licence 5645-9605-01. The job includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, checking the blower and the panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil and sealing the duct connections;\u003c\/li\u003e\n\u003cli\u003ethe outdoor unit on a pad or bracket, brazed piping, the nitrogen test, the vacuum;\u003c\/li\u003e\n\u003cli\u003ethe drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and explanations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAn example January day\u003c\/h3\u003e\n\u003cp\u003eIn the morning, the thermostat calls for heat. The heat pump starts, the warmed air circulates in the same ducts as before and the house slowly rises in temperature, without the jolts of an electric resistance element. If the outdoor temperature plunges below the threshold set at installation, the furnace joins in or takes over. You have nothing to do: the thermostat manages the switching.\u003c\/p\u003e\n\u003cp\u003eIn spring, that same thermostat switches to cooling. The coil cools the air, the drain carries off the condensation and the house stays cool, from the basement to the upstairs bedrooms. One appliance to set, two seasons covered, and the chance to leave the window air conditioners in the garage from the first heat wave.\u003c\/p\u003e\n\n\u003ch3\u003eWhy we keep the furnace\u003c\/h3\u003e\n\u003cp\u003eIn an add-on system, the furnace keeps its blower, its filters and its heating elements. It becomes your safety net in deep cold. Rather than replacing everything, we add a layer of efficiency on top of equipment that still works.\u003c\/p\u003e\n\n\u003ch3\u003eChecks before you buy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-454B requires an outdoor unit using the same refrigerant, installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply to the matched system, not to the coil alone.\u003c\/li\u003e\n\u003cli\u003eThe available height must allow a 29-3\/4 in cabinet.\u003c\/li\u003e\n\u003cli\u003eThe furnace must have the right width and the right blower.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eComfortmaker\u003c\/h3\u003e\n\u003cp\u003eComfortmaker is part of International Comfort Products (ICP), a Carrier subsidiary. Its EVM5X coils are intended for its heat pumps and central air conditioners.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert and Hydro-Québec\u003c\/h3\u003e\n\u003cp\u003eThe matched Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. The amount varies with the installation date and your situation; we confirm it against the official list at the quote stage and prepare the application with you.\u003c\/p\u003e\n\n\u003ch3\u003ePlanning your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCall us for a free in-home estimate: we measure the furnace, check the electrical service and write a quote for the complete Comfortmaker system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e lets you spread the cost over time.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402719064356,"sku":"EVM5X49M21A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EVM5X_EVM5X49M21A_00_4_TONNES_48000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765882","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-evm5x49m21a-v-4-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}