{"product_id":"serpentin-devaporateur-comfortmaker-evm5x60m21a-v-5-tonnes","title":"COMFORTMAKER EVM5X60M21A Evaporator V-Coil | 5 Tons","description":"\u003ch2\u003eThe Comfortmaker EVM5X60M21A: 5 tons in a 21 in width, for large homes with a narrow furnace\u003c\/h2\u003e\n\u003cp\u003eThree questions come up almost every time the owner of a large home calls us about a 5-ton coil: is the furnace wide enough? will the blower keep up? and what does this size change compared with the smaller ones? This page answers those three questions for the \u003cstrong\u003eComfortmaker EVM5X60M21A\u003c\/strong\u003e, a 5-ton (60,000 BTU\/h) cased V-shaped evaporator coil with an insulated cabinet and R-454B refrigerant.\u003c\/p\u003e\n\u003cp\u003eWe install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, on furnaces and blower cabinets already in place.\u003c\/p\u003e\n\n\u003ch3\u003eFirst question: is the furnace wide enough?\u003c\/h3\u003e\n\u003cp\u003eThis model is 21 in wide, like the EVM5X43M21A, EVM5X44M21A, EVM5X48M21A and EVM5X49M21A. That is what sets it apart from its two 5-ton cousins, the EVM5X60M24A and EVM5X61M24A, whose cabinets are 24-1\/2 in wide. If your furnace is 21 in wide, the 60M21A fits it directly. If it is wider, we build an insulated transition, or we steer you toward a 24-1\/2 in model depending on what the measurement shows.\u003c\/p\u003e\n\u003cp\u003ePublished dimensions: 21 × 29-3\/4 in, net weight 49.6 lb. The cabinet is therefore fairly tall: we check the clearance above the furnace before any order.\u003c\/p\u003e\n\n\u003ch3\u003eSecond question: will the blower keep up?\u003c\/h3\u003e\n\u003cp\u003eThis is the decisive question. A 5-ton size calls for more airflow than any of the smaller sizes in the series. A worn-out blower, narrow return ducts or overly restrictive filters would make the coil frost up in summer. So during the visit we check the motor, the plenum size and the returns. Sometimes a small improvement to the distribution fixes everything; more rarely, we recommend a smaller size.\u003c\/p\u003e\n\u003cp\u003eThe multi-position coil accepts upflow, downflow or horizontal airflow: the direction of the air depends on your furnace, not on the coil.\u003c\/p\u003e\n\n\u003ch3\u003eThird question: what does the 5-ton size really change?\u003c\/h3\u003e\n\u003cp\u003eIt increases the exchange surface available to the refrigerant, and that is useful when a large residence has many rooms and windows. But be careful: the coil size is not the output of the complete unit. The real capacity of a system also depends on the outdoor unit. See the published figures:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQ5H9V48*K*AAA, AHRI 217954500: cooling 47,000 BTU\/h, heating 52,000 BTU\/h at 47 °F, SEER2 15.2, HSPF2 9.0;\u003c\/li\u003e\n\u003cli\u003eN5H9V48*K*AAA, AHRI 217954495: cooling 47,000 BTU\/h, heating 52,000 BTU\/h at 47 °F, SEER2 15.2, HSPF2 9.0;\u003c\/li\u003e\n\u003cli\u003eC5H8T48*K*AAA, AHRI 216349401: cooling 48,000 BTU\/h, heating 50,000 BTU\/h at 47 °F, SEER2 16.5, HSPF2 7.8.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn other words, the load calculation determines the outdoor unit; the 5-ton coil is sized to accompany it and to let the air through. Only the AHRI number, which links the two parts, is authoritative for the efficiency ratings.\u003c\/p\u003e\n\n\u003ch3\u003eWhere the 60M21A sits in the series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSmaller: the \u003cstrong\u003eEVM5X43M21A\u003c\/strong\u003e and \u003cstrong\u003eEVM5X44M21A\u003c\/strong\u003e (3.5 tons, matched with the B5H3V36*K*AAA) and the \u003cstrong\u003eEVM5X48M21A\u003c\/strong\u003e and \u003cstrong\u003eEVM5X49M21A\u003c\/strong\u003e (4 tons).\u003c\/li\u003e\n\u003cli\u003eSame size, wider: \u003cstrong\u003eEVM5X60M24A\u003c\/strong\u003e and \u003cstrong\u003eEVM5X61M24A\u003c\/strong\u003e, at 24-1\/2 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTo choose between the 60M21A and the 49M21A, look at the tonnage. With the same main outdoor unit (Q5H9V48*K*AAA), moving from 4 to 5 tons is justified by the volume of air to be handled, not by the capacity of the outdoor unit.\u003c\/p\u003e\n\n\u003ch3\u003eThe technical facts at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003etype: cased evaporator coil, EVM5X range;\u003c\/li\u003e\n\u003cli\u003eexpansion device: TXV;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in liquid, 7\/8 in suction;\u003c\/li\u003e\n\u003cli\u003edrain: sloped PBT pan and three sealed plugs;\u003c\/li\u003e\n\u003cli\u003eA2L leak detection and dissipation system installed or delivered with the unit, per sheet EVM5X-51-01PD;\u003c\/li\u003e\n\u003cli\u003e10-year limited warranty on parts, with registration within 90 days of installation (5 years otherwise).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe coil's role in your furnace heat pump\u003c\/h3\u003e\n\u003cp\u003eInstalled in the plenum, the coil receives the refrigerant from the outdoor unit. In summer, it picks up heat from the air; the condensation water is collected in the pan and carried to the drain. In winter, with a heat pump, the direction of the cycle changes and the outdoor heat is delivered to the air of the home. In a large residence, this distribution through ducts is a big advantage: you do not multiply wall-mounted units.\u003c\/p\u003e\n\u003cp\u003eComfortmaker states that the EVM5X matches with the Q5H9V and N5H9V heat pumps are certified ENERGY STAR cold climate. With a heat pump, the outdoor unit must have a piston expansion device in heating mode.\u003c\/p\u003e\n\n\u003ch3\u003eWhat a large home goes through in summer\u003c\/h3\u003e\n\u003cp\u003eIn a large two-storey home, July heat builds up upstairs, in the south-facing bedrooms and in the home office. Window units are noisy there and leave lukewarm zones. A central system connected to this coil moves the air of the whole house through the existing registers. You set one thermostat, and the air is dried along the way, which eases the sticky, humid feeling.\u003c\/p\u003e\n\u003cp\u003eIn winter, the same duct network spreads the heat from the heat pump, keeping the furnace as backup in deep cold.\u003c\/p\u003e\n\n\u003ch3\u003eWhat we do not do\u003c\/h3\u003e\n\u003cp\u003eWe do not choose a 5-ton coil out of habit, simply because the house is big. A coil too large for its system, or poorly supplied with air, costs more to buy and gives poorer comfort. That is why we start from the load calculation, then check the distribution, and only after that confirm the model. If the 4-ton is enough, we tell you, even if it lowers the quote.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation day\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01. For this job, the crew:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasures the furnace and checks the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalls the coil in the plenum and seals the duct connections, with a custom transition if needed;\u003c\/li\u003e\n\u003cli\u003esets the outdoor unit, brazes the piping, runs the nitrogen test and pulls the vacuum;\u003c\/li\u003e\n\u003cli\u003econnects the drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissions the system, adjusts the airflow and guides you through its use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eBefore you sign\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-454B requires an outdoor unit using the same refrigerant.\u003c\/li\u003e\n\u003cli\u003eThe ratings apply to the certified matched system.\u003c\/li\u003e\n\u003cli\u003eWidth of 21 in, height of 29-3\/4 in and blower airflow: three measurements to confirm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe brand\u003c\/h3\u003e\n\u003cp\u003eComfortmaker belongs to International Comfort Products (ICP), a Carrier subsidiary. The EVM5X60M21A is designed for its heat pumps and central air conditioners.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert rebate\u003c\/h3\u003e\n\u003cp\u003eThe matched Comfortmaker system is listed on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation. We check the official list when we prepare your quote and prepare the application with you.\u003c\/p\u003e\n\n\u003ch3\u003eHave your furnace assessed\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOur on-site estimate is free: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e helps spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402721194276,"sku":"EVM5X60M21A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EVM5X_EVM5X60M21A_00_5_TONNES_60000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765883","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-evm5x60m21a-v-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}