{"product_id":"serpentin-devaporateur-durastar-drbef2414staamc-a-2-tonnes","title":"DURASTAR DRBEF2414STAAMC Evaporator A-Coil | 2 Tons","description":"\u003ch2\u003eDRBEF2414STAAMC: a 2-ton A-coil for the small home heated by a furnace\u003c\/h2\u003e\n\u003cp\u003eIn many townhouses, semi-detached homes and plex units across Greater Montreal, the furnace sits in a corner of the basement and does only one job: heating. The \u003cstrong\u003eDurastar DRBEF2414STAAMC evaporator coil\u003c\/strong\u003e gives it a second one. Mounted on top of the furnace, it receives refrigerant from the outdoor unit and cools the air already moving through your ducts. If the outdoor unit is a heat pump, it also helps heat the home.\u003c\/p\u003e\n\u003cp\u003eThis 2-ton (24,000 BTU\/h) model runs on \u003cstrong\u003eR-454B\u003c\/strong\u003e and comes with its own cabinet, so it is a cased coil. AirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eTwo tons: where the size stops being just right\u003c\/h3\u003e\n\u003cp\u003eThe common reflex is to go bigger \"to be safe\". That is rarely a good idea. An oversized system reaches the requested temperature in a few minutes, shuts off, then starts again. The air gets cooler but does not stay on the coil long enough to leave its moisture behind. The result is a house that feels cool and clammy.\u003c\/p\u003e\n\u003cp\u003eThe 2-ton size is made for smaller homes. With us, the decision starts with measuring your house, never with the catalogue. If our assessment shows you need more, we tell you so and move up to a larger size in the series.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the coil actually does from June to September\u003c\/h3\u003e\n\u003cp\u003eInside the coil's tubes, the refrigerant turns from liquid to gas. To do that, it absorbs heat, and that heat comes from the house air that the blower pushes through the fins. The air comes out cooler, and the moisture it carried condenses on the metal. The water drops into the pan, then goes to the drain.\u003c\/p\u003e\n\u003cp\u003eThe DRBEF2414STAAMC has two 3\/4 in NPT condensate connections. We pick the one that suits the position of the furnace and the place where the water can drain away easily.\u003c\/p\u003e\n\n\u003ch3\u003eAnd in winter? The role in an add-on heat pump\u003c\/h3\u003e\n\u003cp\u003eWhen the outdoor unit is a heat pump, the cycle reverses. The coil becomes the place where heat collected outside is delivered to the house air. Your furnace keeps its blower, its filters and its backup role: below a temperature threshold set with you, it takes over.\u003c\/p\u003e\n\u003cp\u003eThis setup suits an electrically heated home that wants to stop paying full price for every kilowatt-hour. It suits just as well a homeowner who keeps the furnace because it is in good shape and simply wants to add central air conditioning.\u003c\/p\u003e\n\n\u003ch3\u003eThe A shape, and why it matters on top of a furnace\u003c\/h3\u003e\n\u003cp\u003ePicture two fin plates leaning toward each other and joined at the top: that is the \"A\". Air rises from the furnace, passes through the centre, then goes through each face. It is a familiar shape on upflow furnaces, and our technicians have been installing it for a long time.\u003c\/p\u003e\n\u003cp\u003eThe cabinet is supplied with the coil. It spares you a hand-built box and leaves less room for warm air to leak where it should not. The manufacturer lists multi-position installation: upflow, downflow, horizontal left or right. The expansion valve is a TXV, which adjusts the refrigerant flow to the load.\u003c\/p\u003e\n\n\u003ch3\u003eDRBEF2414STAAMC specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: Durastar DRBEF, cased evaporator coil;\u003c\/li\u003e\n\u003cli\u003eNominal capacity: 2 tons, or 24,000 BTU\/h;\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003eExpansion valve: TXV;\u003c\/li\u003e\n\u003cli\u003eLiquid connection: 3\/8 in; suction connection: 3\/4 in;\u003c\/li\u003e\n\u003cli\u003eCondensate: two 3\/4 in NPT connections;\u003c\/li\u003e\n\u003cli\u003eNet weight: 45 lb;\u003c\/li\u003e\n\u003cli\u003eLeak detection: A2L sensor and mitigation board combined in a single housing, factory-installed on models without the L suffix; the outdoor unit pauses if excess refrigerant is detected; compatible with any 24 V thermostat;\u003c\/li\u003e\n\u003cli\u003eManufacturer's warranty: ten years on parts, conditional, with registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eChoosing this model over another in the DRBEF series\u003c\/h3\u003e\n\u003cp\u003eThe series includes ten DRBEF coils in 2-ton and 3-ton capacities. Here is how they differ, based on the data sheets:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eShape.\u003c\/strong\u003e The DRBEF2414STAAMC is an \"A\". Its siblings DRBEF2417MTANMC, DRBEF2417STANMC, DRBEF2421HTANMC and DRBEF2421MTANMC are \"N\" coils, also 2 tons;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eListed width.\u003c\/strong\u003e The DRBEF2417MTANMC and DRBEF2417STANMC list 17-1\/2 in. Ours does not: we measure the furnace and check the fit before ordering;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCapacity.\u003c\/strong\u003e For a larger home, the series offers 3-ton models, including the DRBEF3621HTAAMC, also an \"A\";\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConstants.\u003c\/strong\u003e All of them share R-454B and the TXV expansion valve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRemember this: if your furnace has room above it and the home is modest, this 2-ton \"A\" is the natural starting point. If height is short, look at one of the \"N\" coils.\u003c\/p\u003e\n\n\u003ch3\u003eMatching with the outdoor unit\u003c\/h3\u003e\n\u003cp\u003eA coil on its own has no efficiency rating. The figures you see on brochures, such as SEER2 or HSPF2, describe a system: a specific coil, a specific outdoor unit and an AHRI number that ties them together. For the DRBEF2414STAAMC, we match it with a Durastar unit of the same capacity and the same refrigerant.\u003c\/p\u003e\n\u003cp\u003eBefore placing the order, we look up that AHRI number in the official directory. That way, when a quote states a rating, it matches what you will receive. It is also a good way to compare two offers honestly.\u003c\/p\u003e\n\n\u003ch3\u003eA typical day at your home\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe measure the furnace, check the blower and take a look at the electrical panel;\u003c\/li\u003e\n\u003cli\u003eWe set the coil in the plenum, with an insulated transition built on site if needed, then seal the joints;\u003c\/li\u003e\n\u003cli\u003eThe outdoor unit goes on a pad or bracket; the piping is brazed, tested with nitrogen, then put under vacuum;\u003c\/li\u003e\n\u003cli\u003eWe connect the drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003eWe start the system, set the airflow and show you how to use it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRefrigeration, ventilation and electrical work is carried out under RBQ licence 5645-9605-01. AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years.\u003c\/p\u003e\n\n\u003ch3\u003eTo check before ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe outdoor unit must use R-454B, like the coil, and be installed at the same time;\u003c\/li\u003e\n\u003cli\u003eThe furnace width must match the cabinet; if not, we build a transition;\u003c\/li\u003e\n\u003cli\u003eThe blower must deliver the airflow the system calls for;\u003c\/li\u003e\n\u003cli\u003ePublished ratings apply to the certified match, not to just any combination.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA word on noise and everyday comfort\u003c\/h3\u003e\n\u003cp\u003eThe coil makes no noise on its own: it is the furnace blower that moves the air. So we set the airflow so that air circulates without whistling at the registers. In a small home, a well-calibrated airflow shows mostly in the absence of cold drafts near the grilles.\u003c\/p\u003e\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eEligibility for Hydro-Québec programs, including LogisVert, depends on the complete system and not on the coil alone. Depending on the installation date, we check the official list when we prepare your quote and tell you what applies to your project.\u003c\/p\u003e\n\n\u003ch3\u003eWhy a brand like Durastar\u003c\/h3\u003e\n\u003cp\u003eDurastar is the heating and cooling brand of Ferguson, distributed in Canada by Wolseley. Its DRBEF coils running on R-454B go with the brand's heat pumps and central air conditioners, installed on a furnace.\u003c\/p\u003e\n\n\u003ch2\u003eRequest your estimate\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Durastar system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Durastar","offers":[{"title":"Default Title","offer_id":68402708775204,"sku":"DRBEF2414STAAMC","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_DURASTAR_DRBEF_DRBEF2414STAAMC_00_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765884","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-durastar-drbef2414staamc-a-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}