{"product_id":"serpentin-devaporateur-durastar-drbef2417mtanmc-n-2-tonnes","title":"DURASTAR DRBEF2417MTANMC Evaporator N-Coil | 2 Tons","description":"\u003ch2\u003eDRBEF2417MTANMC: a 2-ton N-coil, 17-1\/2 in wide, for a tight furnace\u003c\/h2\u003e\n\u003cp\u003eWhen you open the plenum of an older furnace, the first question is not \"which brand?\" but \"how much room is left?\". That is where the \u003cstrong\u003eDurastar DRBEF2417MTANMC evaporator coil\u003c\/strong\u003e earns its place. Its N shape and listed width of 17-1\/2 in make it a serious candidate for smaller furnaces, which are often found in bungalows, semi-detached homes and plex units.\u003c\/p\u003e\n\u003cp\u003eIt is a 2-ton (24,000 BTU\/h) model, using \u003cstrong\u003eR-454B refrigerant\u003c\/strong\u003e, supplied with its cabinet, so it is a cased coil. We install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWidth first: what does 17-1\/2 in mean in your home?\u003c\/h3\u003e\n\u003cp\u003eThe data sheet gives 17-1\/2 in for the coil width. Your furnace has its own width, and the two are not always the same. When the gap is small, an insulated transition built on site settles the matter cleanly. When the gap is large, it is better to know before ordering than in front of an open box in the basement.\u003c\/p\u003e\n\u003cp\u003eThat is why the estimate visit starts with a tape measure. We take the width, then the height available above the furnace. Only then do we confirm the model.\u003c\/p\u003e\n\n\u003ch3\u003eUnderstanding the N shape\u003c\/h3\u003e\n\u003cp\u003eAn N-coil folds its fins in a zigzag, with three faces instead of two. The resulting cabinet is lower than an A-coil of similar capacity. That is its selling point: it slips in where the \"A\" will not fit, under a beam, near a low ceiling or in a small utility closet.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer lists multi-position installation: upflow, downflow, horizontal left or right. The expansion valve is a TXV, which meters the refrigerant according to the demand of the air passing through.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the coil does for your comfort\u003c\/h3\u003e\n\u003cp\u003eIn summer, the refrigerant evaporates in the tubes and removes heat from the house air. Moisture condenses along the way, falls into the pan and runs to the drain, which here has two 3\/4 in NPT connections. You get cooler, drier air in every room, with no window units.\u003c\/p\u003e\n\u003cp\u003eIn winter, if the outdoor unit is a heat pump, the cycle runs the other way and the home is heated through the same ducts. The furnace then keeps a backup role for the coldest days.\u003c\/p\u003e\n\n\u003ch3\u003eOn the data sheet: the numbers to remember\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel: DRBEF2417MTANMC, cased coil, DRBEF series;\u003c\/li\u003e\n\u003cli\u003eNominal size: 2 tons, or 24,000 BTU\/h;\u003c\/li\u003e\n\u003cli\u003eWidth: 17-1\/2 in;\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-454B; expansion valve: TXV;\u003c\/li\u003e\n\u003cli\u003eConnections: 3\/8 in for liquid, 3\/4 in for suction;\u003c\/li\u003e\n\u003cli\u003eNet weight: 49 lb;\u003c\/li\u003e\n\u003cli\u003eBuilt-in leak detection: A2L sensor and mitigation board factory-installed (models without the L suffix), which pauses the outdoor unit if excess refrigerant is detected, compatible with any 24 V thermostat;\u003c\/li\u003e\n\u003cli\u003eConditional 10-year parts warranty, with registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhere it fits among its siblings in the DRBEF series\u003c\/h3\u003e\n\u003cp\u003eHere is a short decision guide, built only on the series data sheets:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eYour furnace is narrow and height is limited:\u003c\/strong\u003e this DRBEF2417MTANMC, or its neighbour the DRBEF2417STANMC, both 2-ton \"N\" coils at 17-1\/2 in;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeight is not a concern:\u003c\/strong\u003e the DRBEF2414STAAMC, a 2-ton \"A\";\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eYou are torn between two 2-ton N-shaped models:\u003c\/strong\u003e the DRBEF2421HTANMC and DRBEF2421MTANMC list no width on their data sheets; we compare them with your plenum during the visit;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eThe house is larger:\u003c\/strong\u003e step up to 3 tons, with for example the DRBEF3617STANMC, also a 17-1\/2 in \"N\".\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBetween the DRBEF2417MTANMC and the DRBEF2417STANMC, the shape, capacity, width, refrigerant and expansion valve are the same. The net weight differs; we confirm the exact difference on the manufacturer's data sheet when ordering.\u003c\/p\u003e\n\n\u003ch3\u003eThe coil does not work alone\u003c\/h3\u003e\n\u003cp\u003eA coil has no efficiency rating on its own. What you read in advertising (SEER2, EER2, HSPF2) belongs to a certified system, tied together by an AHRI number. We check that number in the directory before ordering the outdoor unit, which must have the same capacity and the same refrigerant.\u003c\/p\u003e\n\u003cp\u003eThis detail carries real weight: two quotes can look equivalent when one of them presents an uncertified match. The AHRI number is your proof.\u003c\/p\u003e\n\n\u003ch3\u003eOur installation, from measurement to start-up\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasuring the furnace, checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003eSetting the coil in the plenum and sealing the duct connections;\u003c\/li\u003e\n\u003cli\u003eInstalling the outdoor unit, brazed piping, nitrogen test and vacuum;\u003c\/li\u003e\n\u003cli\u003eConnecting the drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003eStart-up, airflow adjustment and a walk-through at your home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAll our refrigeration, ventilation and electrical work is covered by RBQ licence 5645-9605-01. AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years.\u003c\/p\u003e\n\n\u003ch3\u003eChecks before you buy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil's R-454B calls for an outdoor unit with the same refrigerant, installed at the same time;\u003c\/li\u003e\n\u003cli\u003eThe blower must be able to push the airflow the system needs;\u003c\/li\u003e\n\u003cli\u003ePublished ratings apply only to the certified match.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe steps that avoid bad surprises\u003c\/h3\u003e\n\u003cp\u003eA well-chosen coil can still perform poorly if the air has no path. So we check the condition of the filters, the cleanliness of the blower and the tightness of the ducts near the plenum. An air leak in a basement duct hurts comfort far more than the difference between two coil models.\u003c\/p\u003e\n\u003cp\u003eWe also check the slope of the drain. Condensate must leave freely, without backing up or standing in the pan. In Montreal and Longueuil homes with a low basement floor, this sometimes means planning a careful drainage path; we talk about it during the visit, not on installation day.\u003c\/p\u003e\n\u003cp\u003eFinally, we explain the maintenance routine: change the filter at regular intervals, keep the outdoor unit clear of snow and leaves, and check from time to time that the drain runs normally. These small steps help the whole system last.\u003c\/p\u003e\n\u003ch3\u003ePlanning the right time for the work\u003c\/h3\u003e\n\u003cp\u003eReplacing or adding a coil is simpler in spring or fall, when the furnace is not needed every day. During the cold season, we schedule the installation so that your home stays heated from morning to night. Call us early: a calendar booked in advance avoids deciding in the rush of a breakdown.\u003c\/p\u003e\n\u003ch3\u003eIncentives: LogisVert and more\u003c\/h3\u003e\n\u003cp\u003eWhether you are aiming for LogisVert or another Hydro-Québec program, eligibility rests on the complete system, not on the coil taken alone. We check the official list according to the installation date and tell you what applies before you sign.\u003c\/p\u003e\n\n\u003ch3\u003eDurastar in two sentences\u003c\/h3\u003e\n\u003cp\u003eDurastar is the heating and cooling brand of Ferguson, distributed in Canada by Wolseley. Its DRBEF coils running on R-454B are installed on a furnace and go with the brand's heat pumps and central air conditioners.\u003c\/p\u003e\n\n\u003ch2\u003eTake the next step\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Durastar system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Durastar","offers":[{"title":"Default Title","offer_id":68402709561636,"sku":"DRBEF2417MTANMC","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_DURASTAR_DRBEF_DRBEF2417MTANMC_00_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765883","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-durastar-drbef2417mtanmc-n-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}