{"product_id":"serpentin-devaporateur-durastar-drbef2417stanmc-n-2-tonnes","title":"DURASTAR DRBEF2417STANMC Evaporator N-Coil | 2 Tons","description":"\u003ch2\u003eThe DRBEF2417STANMC: a 43 lb N-coil, 2 tons, for a basement staircase that forgives nothing\u003c\/h2\u003e\n\u003cp\u003eEquipment that does not fit well into the house is installed badly. Before capacity and refrigerant, we think about the route: front door, staircase, the corner of the mechanical room. At 43 lb net, the \u003cstrong\u003eDurastar DRBEF2417STANMC evaporator coil\u003c\/strong\u003e can be handled without special equipment, which matters in finished basements in Montreal, Laval and Longueuil.\u003c\/p\u003e\n\u003cp\u003eIt is a 2-ton (24,000 BTU\/h) N-coil with a cabinet, so a cased coil, 17-1\/2 in wide, running on \u003cstrong\u003eR-454B\u003c\/strong\u003e. Our team also installs it on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eAt a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eA coil that completes an existing furnace;\u003c\/li\u003e\n\u003cli\u003eAir conditioning in summer; heating in winter with a heat pump;\u003c\/li\u003e\n\u003cli\u003eA required match with an outdoor unit of the same capacity and the same refrigerant;\u003c\/li\u003e\n\u003cli\u003eInstallation in a single pass, with the furnace kept in place.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe coil's route, from the van to the furnace\u003c\/h3\u003e\n\u003cp\u003eThe cabinet arrives ready to install. Two technicians carry it to the plenum, shim it, then connect it. At 43 lb, it needs no mechanical lifting: no hoist or scaffolding. That reduces the risk of scuffing a finished wall or a step.\u003c\/p\u003e\n\u003cp\u003eOnce in place, we seal the duct joints and check that nothing moves. A poorly shimmed coil produces vibration, then condensation in places where it has no business being.\u003c\/p\u003e\n\n\u003ch3\u003eN shape: three faces, a lower cabinet\u003c\/h3\u003e\n\u003cp\u003eThe fins of an N-coil form a zigzag. They offer the needed heat-exchange surface in a shorter volume than an A-coil. Under a beam, at the bottom of a basement ceiling or in a small utility room, that economy of height makes all the difference.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer lists multi-position installation: upflow, downflow, horizontal left or right. A TXV-type expansion valve adjusts the refrigerant supply according to the air temperature.\u003c\/p\u003e\n\n\u003ch3\u003eWhat you cannot see: leak detection\u003c\/h3\u003e\n\u003cp\u003eRefrigerants in the A2L family, including R-454B, have led manufacturers to build in a safety device. On this model, an A2L sensor and a mitigation board are combined in a single housing, factory-installed on models without the L suffix. If excess refrigerant is detected, the outdoor unit pauses. The whole thing works with any 24 V thermostat.\u003c\/p\u003e\n\n\u003ch3\u003eData sheet details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal capacity: 2 tons, 24,000 BTU\/h;\u003c\/li\u003e\n\u003cli\u003eWidth: 17-1\/2 in; net weight: 43 lb;\u003c\/li\u003e\n\u003cli\u003eR-454B refrigerant, TXV expansion valve;\u003c\/li\u003e\n\u003cli\u003e3\/8 in liquid connection, 3\/4 in suction;\u003c\/li\u003e\n\u003cli\u003eTwo 3\/4 in NPT condensate connections;\u003c\/li\u003e\n\u003cli\u003eDRBEF series; type: cased evaporator coil;\u003c\/li\u003e\n\u003cli\u003eWarranty: ten years on parts, subject to registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow to tell this model from its siblings\u003c\/h3\u003e\n\u003cp\u003eThe DRBEF2417STANMC looks a lot like the DRBEF2417MTANMC: same N shape, same 2-ton capacity, same 17-1\/2 in width, same R-454B and same TXV. The difference visible on the data sheets comes down to net weight and part reference. Ask us for the comparison at the estimate; we draw it up from the manufacturer's document.\u003c\/p\u003e\n\u003cp\u003eOther pointers to decide:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA 2-ton \"A\" such as the DRBEF2414STAAMC takes more height than an \"N\";\u003c\/li\u003e\n\u003cli\u003eThe DRBEF2421HTANMC and DRBEF2421MTANMC are also 2-ton \"N\" coils, with no width listed on the data sheet;\u003c\/li\u003e\n\u003cli\u003eFor a larger home, look at the 3-ton models; the DRBEF3617STANMC keeps the 17-1\/2 in width.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe complete system: who talks to whom\u003c\/h3\u003e\n\u003cp\u003eThe coil, on its own, has no efficiency rating. The SEER2 and HSPF2 ratings in circulation describe a match, tied to an AHRI number. Before ordering, we look up that number for the chosen outdoor unit, so that the promise in the quote is exactly that of the equipment delivered.\u003c\/p\u003e\n\u003cp\u003eOur rule is simple: a coil and an outdoor unit that do not appear together in the directory are not matched at AirGreen.\u003c\/p\u003e\n\n\u003ch3\u003eA five-step installation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVisit: measuring the furnace, the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003eCoil: set in the plenum, insulated transition if needed;\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: pad or bracket, brazed piping, nitrogen test, vacuum;\u003c\/li\u003e\n\u003cli\u003eConnections: condensate drain, thermostat;\u003c\/li\u003e\n\u003cli\u003eTesting: start-up, airflow adjustment, walk-through.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe work is carried out under RBQ licence 5645-9605-01. AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years.\u003c\/p\u003e\n\n\u003ch3\u003eBefore you say yes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSame refrigerant on both sides: R-454B;\u003c\/li\u003e\n\u003cli\u003eFurnace width confirmed against the 17-1\/2 in;\u003c\/li\u003e\n\u003cli\u003eBlower able to deliver the airflow required;\u003c\/li\u003e\n\u003cli\u003eRatings read from the certified match, not from the coil alone.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eGetting an installation right in a finished basement\u003c\/h3\u003e\n\u003cp\u003eMany of our customers have finished their basements: suspended ceiling, playroom, small office. In that case, the mechanical room is often the only place left unfinished, and space there is tight. We take the time to protect the floors, cover nearby surfaces and locate the piping pass-throughs before starting.\u003c\/p\u003e\n\u003cp\u003eThe refrigerant piping between the furnace and the outdoor unit follows a route that we plan with you. We look for the shortest and most discreet path, without kinking the tubes, and we insulate what needs it. A good layout also simplifies future service.\u003c\/p\u003e\n\n\u003ch3\u003eQuestions we are often asked\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this coil provide heat?\u003c\/strong\u003e Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner, it only provides cooling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I keep my current air conditioner?\u003c\/strong\u003e Generally no. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat if my furnace is not the same width?\u003c\/strong\u003e We measure it and, if needed, build an insulated transition on site.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the furnace still useful?\u003c\/strong\u003e Yes. It keeps its blower and takes over when the outdoor temperature falls below the threshold we program with you.\u003c\/p\u003e\n\u003ch3\u003eOne simple step after installation\u003c\/h3\u003e\n\u003cp\u003eFill out the manufacturer's registration form: that is what makes the ten-year parts warranty applicable. We help you do it on start-up day, so nothing is forgotten.\u003c\/p\u003e\n\u003ch3\u003eMaintaining what you cannot see\u003c\/h3\u003e\n\u003cp\u003eOnce the cabinet is closed up, nobody looks at it for years. Yet that is where dust builds up on the fins and where the pan can collect deposits. A check before the warm season lets us clean what needs cleaning, check the drain and make sure the airflow has not dropped. It takes little time and protects the investment.\u003c\/p\u003e\n\u003ch3\u003eFinancial help\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec incentives, notably LogisVert, are tied to the complete system. The amount and eligibility vary with the installation date: we check the official list when we prepare your quote and tell you what concerns your file.\u003c\/p\u003e\n\n\u003ch3\u003eThe manufacturer\u003c\/h3\u003e\n\u003cp\u003eDurastar is the heating and cooling brand of Ferguson; Wolseley distributes it in Canada. DRBEF coils running on R-454B are installed on a furnace to complete Durastar heat pumps and central air conditioners.\u003c\/p\u003e\n\n\u003ch2\u003eNext step: the estimate\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Durastar system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Durastar","offers":[{"title":"Default Title","offer_id":68402710511908,"sku":"DRBEF2417STANMC","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_DURASTAR_DRBEF_DRBEF2417STANMC_00_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765884","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-durastar-drbef2417stanmc-n-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}