{"product_id":"serpentin-devaporateur-durastar-drbef2421heaamc-a-2-tonnes","title":"DURASTAR DRBEF2421HEAAMC Evaporator A-Coil | 2 Tons","description":"\u003ch2\u003eDRBEF2421HEAAMC: a 2-ton A-coil to replace an old central air conditioner\u003c\/h2\u003e\n\u003cp\u003eIs your central air conditioner wearing out, or have you never had one and your furnace has been running for years? The \u003cstrong\u003eDurastar DRBEF2421HEAAMC evaporator coil\u003c\/strong\u003e is worth a close look. It is an A-shaped coil that ships with its cabinet, runs on \u003cstrong\u003eR-454B refrigerant\u003c\/strong\u003e and is sized at 2 tons (24,000 BTU\/h). It sits on your existing furnace and receives refrigerant from a matching Durastar outdoor unit. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eFive questions homeowners ask us\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this coil provide heat?\u003c\/strong\u003e Yes, as long as it is paired with a heat pump: it cools in summer and heats in winter. With a simple central air conditioner, it only provides cooling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I keep my current air conditioner?\u003c\/strong\u003e Generally, no. This coil runs on R-454B and must connect to the outdoor unit the manufacturer specifies. We install both parts together.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs my furnace the right width?\u003c\/strong\u003e We measure it before ordering. If it differs from the cabinet, we prepare an insulated transition on site.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the furnace become useless?\u003c\/strong\u003e No. It keeps its blower, and it takes over when the outdoor temperature drops below the threshold we set with you.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat about incentives?\u003c\/strong\u003e They depend on the matched system, and we come back to that below.\u003c\/p\u003e\n\n\u003ch3\u003eWhy an A-coil\u003c\/h3\u003e\n\u003cp\u003eThe A is a coil shape with two sloped faces that meet at the top. Air rises through the centre of the furnace and passes along each side. This geometry is very common above upflow furnaces, and it is the one we install most often when the ceiling height in the basement is not an obstacle.\u003c\/p\u003e\n\u003cp\u003eIf height is lacking, the N shape of the DRBEF2421HEANMC or the DRBEF2421MEANMC, with the same capacity, will be a better fit. We check with a tape measure before choosing, not after.\u003c\/p\u003e\n\n\u003ch3\u003eHow the cooling cycle works inside it\u003c\/h3\u003e\n\u003cp\u003eIn the coil's tubes, liquid refrigerant turns to vapour as it absorbs heat from your home's air. Moisture in that air settles on the cold fins and drips into the pan, from which two 3\/4 in NPT condensate connections carry it away. The furnace blower then redistributes the cooled air to every room through the existing ducts.\u003c\/p\u003e\n\u003cp\u003eThe metering device, an EEV for this model, regulates the flow of refrigerant admitted to the coil. It keeps the coil in its normal operating range, without icing or a shortfall in capacity.\u003c\/p\u003e\n\n\u003ch3\u003eThe connections and weight to know about\u003c\/h3\u003e\n\u003cp\u003eThis model stands apart from its 2-ton cousins with its 7\/8 in suction connection (the liquid line stays at 3\/8 in) and a net weight of 76 lb. For the installer, these are concrete details: they determine the size of the copper piping to the outdoor unit and how the cabinet is handled on a basement staircase.\u003c\/p\u003e\n\u003cp\u003eThe DRBEF2421MEANMC, for example, has a smaller suction connection and a much lighter cabinet. If your job site is tight, this point can tip the balance.\u003c\/p\u003e\n\n\u003ch3\u003eDRBEF2421HEAAMC at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ebrand and range: Durastar, DRBEF;\u003c\/li\u003e\n\u003cli\u003ecased A-coil model, 2 tons, R-454B;\u003c\/li\u003e\n\u003cli\u003epositions: upflow, downflow, horizontal left or right;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in liquid, 7\/8 in suction;\u003c\/li\u003e\n\u003cli\u003enet weight: 76 lb;\u003c\/li\u003e\n\u003cli\u003emanufacturer warranty: conditional 10-year parts warranty, with registration (sheet CDS-228);\u003c\/li\u003e\n\u003cli\u003eleak detection: A2L sensor and mitigation board factory-installed in a single housing, pausing the outdoor unit if excess refrigerant is detected; compatible with any 24 V thermostat.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEfficiency ratings that belong to the system\u003c\/h3\u003e\n\u003cp\u003eDon't look for a SEER2 for the coil alone: it doesn't have one. The published ratings apply to a complete matched system, identified by an AHRI number. According to Durastar, the DRHP14B and DRHP15B heat pumps from the DRAC series on R-454B, with a two-stage compressor, pair with DRBEF coils; most of these combinations show a SEER2 of 15.2, an EER2 of 11.7 and an HSPF2 of 7.8. We confirm the exact combination before the order.\u003c\/p\u003e\n\n\u003ch3\u003eChoosing between this model and its neighbours in the series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eA-coil or N-coil\u003c\/strong\u003e: this coil is an A-coil. The DRBEF2421HEANMC, DRBEF2421MEANMC and DRBEF2417SEANMC are N-coils.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e: 2 tons here. The DRBEF3621MEAAMC is also an A-coil, but at 3 tons; it suits a larger or more glazed home.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e: this model's sheet does not publish the width; we confirm it on site. The DRBEF2417SEANMC shows 17-1\/2 in, which makes it the natural choice for a narrow space.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMetering device and refrigerant\u003c\/strong\u003e: EEV and R-454B, like almost every model in the series (only the DRBEF6024STANMC has a TXV).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow Quebec's climate changes the choice\u003c\/h3\u003e\n\u003cp\u003eOur summers are short, but humid. One heat-wave week in July is enough to turn a basement or a second floor into a steam room. A properly sized central air conditioner handles the temperature and the humidity at once, whereas a window unit looks after only one room. The 2-ton A-coil is cut out for homes where the load is moderate and a single zone is enough.\u003c\/p\u003e\n\u003cp\u003eIf, on the contrary, your upper rooms overheat while the basement stays cool, a single system won't fix everything. We say so during the visit, because it is better to correct the air circulation or the insulation than to buy more tons.\u003c\/p\u003e\n\n\u003ch3\u003eWhy we install the outdoor unit and the coil on the same day\u003c\/h3\u003e\n\u003cp\u003eA new coil connected to an old outdoor unit is like a chain with a worn link: the capacity, the refrigerant and the piping must agree. Since this model runs on R-454B, the outdoor unit must use the same fluid. Installing both parts together lets us braze new piping, pressure-test with nitrogen and pull the vacuum once, with a single commissioning report to hand you.\u003c\/p\u003e\n\n\u003ch3\u003eHow an installation with AirGreen unfolds\u003c\/h3\u003e\n\u003cp\u003eA family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company based in Montreal for more than fifteen years, AirGreen does its own refrigeration, ventilation and electrical work under RBQ licence 5645-9605-01. For this coil, here are our steps:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring visit: furnace, blower, electrical panel;\u003c\/li\u003e\n\u003cli\u003esetting the cabinet in the plenum and sealing the duct connections;\u003c\/li\u003e\n\u003cli\u003emounting the outdoor unit, brazed piping, nitrogen test, vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment, handing over the operating instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePoints to validate before you sign\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-454B requires pairing the coil with an outdoor unit using the same refrigerant.\u003c\/li\u003e\n\u003cli\u003eThe furnace blower must deliver the required airflow.\u003c\/li\u003e\n\u003cli\u003eThe house's load calculation must confirm that 2 tons is the right choice.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFinancial assistance programs\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec incentives are tied to the complete system. We check the official list based on the installation date, then explain what applies before you sign anything.\u003c\/p\u003e\n\n\u003ch3\u003eTaking the next step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate. We measure the furnace, check the electrical service and give you a written quote for the complete Durastar system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e lets you spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Durastar","offers":[{"title":"Default Title","offer_id":68402727321892,"sku":"DRBEF2421HEAAMC","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_DURASTAR_DRBEF_DRBEF2421HEAAMC_00_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765885","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-durastar-drbef2421heaamc-a-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}