{"product_id":"serpentin-devaporateur-durastar-drbef2421heanmc-n-2-tonnes","title":"DURASTAR DRBEF2421HEANMC Evaporator N-Coil | 2 Tons","description":"\u003ch2\u003eLow basement, low ceiling: the DRBEF2421HEANMC, a 2-ton N-coil\u003c\/h2\u003e\n\u003cp\u003eIn many Greater Montreal homes, the furnace sits in a basement corner where a beam, a duct or a dropped ceiling limits the height. That is exactly the setting for which you choose an N-shaped coil. The \u003cstrong\u003eDRBEF2421HEANMC\u003c\/strong\u003e is a 2-ton (24,000 BTU\/h) Durastar evaporator coil, cased, running on \u003cstrong\u003eR-454B refrigerant\u003c\/strong\u003e. AirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eA common scenario\u003c\/h3\u003e\n\u003cp\u003eA family in Longueuil owns a bungalow from past decades with an electric furnace. They want to cool in summer and cut the winter bill. In the mechanical room, there is little clearance left between the top of the furnace and the ceiling. An A-coil wouldn't fit without moving everything; an N-coil slips into the same space.\u003c\/p\u003e\n\u003cp\u003eThis kind of constraint is settled with a tape measure, not a catalogue. During our visit, we measure the available height before we even talk about brands.\u003c\/p\u003e\n\n\u003ch3\u003eThe N shape, concretely\u003c\/h3\u003e\n\u003cp\u003eThe coil's tubing is folded into three zigzag faces. The whole is shorter than the A version for the same capacity, which gives a cabinet better suited to tight spaces. The DRBEF2421HEANMC ships in an insulated cabinet, ready to set on the furnace, which cuts installation time and limits air leaks around the coil.\u003c\/p\u003e\n\u003cp\u003eIt mounts in upflow, downflow or horizontal position, left or right.\u003c\/p\u003e\n\n\u003ch3\u003eWhat it brings to an add-on system\u003c\/h3\u003e\n\u003cp\u003eYour furnace keeps its role as the air mover: its blower, filters and ducts stay in place. The coil is inserted in the path of the air. In summer, it removes heat and humidity; in winter, when paired with a heat pump, it returns heat. The furnace only steps in if the outdoor temperature drops below the threshold programmed with you, for example during a January cold snap.\u003c\/p\u003e\n\n\u003ch3\u003eNo rating on its own, but a certified system\u003c\/h3\u003e\n\u003cp\u003eA coil carries no SEER2 or HSPF2 rating of its own. Those figures belong to the coil and outdoor unit together, linked by an AHRI number. Durastar publishes combinations with its DRHP14B and DRHP15B heat pumps (DRAC series, R-454B, two-stage compressor): those not certified for cold climates show a SEER2 of 15.2, an EER2 of 11.7 and an HSPF2 of 7.8. We verify the exact combination before buying, so that the ratings promised are the ones you get.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical data for the model\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emodel: DRBEF2421HEANMC, Durastar DRBEF range;\u003c\/li\u003e\n\u003cli\u003etype: cased N-coil;\u003c\/li\u003e\n\u003cli\u003esize: 2 tons, 24,000 BTU\/h;\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B, EEV metering;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in (liquid) and 7\/8 in (suction);\u003c\/li\u003e\n\u003cli\u003econdensate drain: two 3\/4 in NPT connections;\u003c\/li\u003e\n\u003cli\u003enet weight: 71 lb;\u003c\/li\u003e\n\u003cli\u003ewarranty: conditional 10-year parts warranty, with registration (sheet CDS-228);\u003c\/li\u003e\n\u003cli\u003esafety: factory A2L sensor and mitigation board, which pause the outdoor unit if excess refrigerant is detected; works with any 24 V thermostat.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe DRBEF2421HEANMC compared with its neighbours\u003c\/h3\u003e\n\u003cp\u003eWhen the choice comes down to several similar-looking model numbers, here are the differences we keep in mind for you.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eVersus the DRBEF2421HEAAMC\u003c\/strong\u003e: same capacity, same connections, but an A-coil. If your ceiling is low, the N shape of this model is the one to pick; if you have height, the A remains possible. The N cabinet is also a little lighter than the A.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eVersus the DRBEF2421MEANMC\u003c\/strong\u003e: same shape, same capacity, but the latter has a smaller suction connection and weighs noticeably less.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eVersus the DRBEF2417SEANMC\u003c\/strong\u003e: same capacity and same shape, with a cabinet whose published width is 17-1\/2 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eVersus the DRBEF3621MEANMC\u003c\/strong\u003e: same shape, but 3 tons, for a larger home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe winter bill, explained simply\u003c\/h3\u003e\n\u003cp\u003eAn electric furnace turns every kilowatt-hour into an equal amount of heat. A heat pump instead moves heat from outside to inside: in mild weather, it delivers two to three times more heat than the electricity it consumes. That efficiency drops with the cold, which is why the furnace stays as backup. The N-coil in this model is the link that brings that heat into your existing ducts.\u003c\/p\u003e\n\u003cp\u003eWe set with you the temperature threshold at which the furnace takes over. For a family in Laval or on the North Shore, that means a heat pump that works most of the season and a furnace that holds itself in reserve for cold peaks.\u003c\/p\u003e\n\n\u003ch3\u003eWhat we check before installing\u003c\/h3\u003e\n\u003cp\u003eThe plenum must be able to receive the cabinet without crushing the filter or blocking access to components. We also look at the alignment of the drain, because condensation water must flow to a low point with no slope running the wrong way. Finally, we check that the electrical circuit for the outdoor unit is ready to take the heat pump's load. These three points avoid most surprises on installation day.\u003c\/p\u003e\n\n\u003ch3\u003eOur installation method\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company in Montreal, active for more than fifteen years, holding RBQ licence 5645-9605-01 for its refrigeration, ventilation and electrical work.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eWe take the measurements: available height, furnace width, condition of the electrical panel.\u003c\/li\u003e\n\u003cli\u003eWe set the cabinet in the plenum, and we seal the connections with the ducts.\u003c\/li\u003e\n\u003cli\u003eWe install the outdoor unit, braze the piping, pressure-test with nitrogen, then pull the vacuum.\u003c\/li\u003e\n\u003cli\u003eWe connect the drain and the thermostat.\u003c\/li\u003e\n\u003cli\u003eWe start up the system, adjust the airflow and show you the settings.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eBefore you decide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil and the outdoor unit are chosen at the same time, with the same refrigerant.\u003c\/li\u003e\n\u003cli\u003eThe furnace width, unknown on the spec sheet, is checked on site.\u003c\/li\u003e\n\u003cli\u003eThe blower must deliver the system's airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eMaintenance: what you can do yourself\u003c\/h3\u003e\n\u003cp\u003eA clean coil works better. The simplest step is to change the furnace filter at the rate the manufacturer recommends, since dust that gets past the filter ends up on the fins. Also keep an eye on the drain: if you see water around the cabinet in the middle of a heat wave, call us before the floor suffers. An annual check before summer lets us clean the pan and confirm that the leak sensor and the thermostat are communicating properly.\u003c\/p\u003e\n\u003cp\u003eWe don't promise a specific lifespan for any unit, because it depends on the quality of the installation, the maintenance and the use. What we do guarantee is an installation done to the standards of the trade.\u003c\/p\u003e\n\n\u003ch3\u003eGovernment assistance\u003c\/h3\u003e\n\u003cp\u003eEligibility for incentives depends on the matched system and not on the coil alone. We consult the official Hydro-Québec list based on the installation date and tell you what applies.\u003c\/p\u003e\n\n\u003ch3\u003eYour estimate, on site\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBook your free estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Durastar system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Durastar","offers":[{"title":"Default Title","offer_id":68402727616804,"sku":"DRBEF2421HEANMC","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_DURASTAR_DRBEF_DRBEF2421HEANMC_00_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765885","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-durastar-drbef2421heanmc-n-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}