{"product_id":"serpentin-devaporateur-durastar-drbef2421htanmc-n-2-tonnes","title":"DURASTAR DRBEF2421HTANMC Evaporator N-Coil | 2 Tons","description":"\u003ch2\u003eDRBEF2421HTANMC: a 2-ton N-coil, 7\/8 in suction and 71 lb of well-seated metal\u003c\/h2\u003e\n\u003cp\u003eSome coils are chosen by capacity. Others are read by their piping. The \u003cstrong\u003eDurastar DRBEF2421HTANMC\u003c\/strong\u003e belongs to the second category: its data sheet lists a 7\/8 in suction connection, larger than that of several 2-ton models in the series, and a net weight of 71 lb. Those two details steer the installation, long before anyone talks about thermostat colour.\u003c\/p\u003e\n\u003cp\u003eThis 2-ton (24,000 BTU\/h) N-coil, supplied in a cabinet and so a cased coil, uses \u003cstrong\u003eR-454B refrigerant\u003c\/strong\u003e. AirGreen connects it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhy the suction diameter deserves a closer look\u003c\/h3\u003e\n\u003cp\u003eTwo tubes run between the outdoor unit and the coil. The thinner one carries liquid refrigerant: here, 3\/8 in. The larger one brings the gas back to the compressor: here, 7\/8 in. A tube that is too narrow hampers that return; a poorly insulated tube lets heat creep in along the way.\u003c\/p\u003e\n\u003cp\u003eOur job is to connect those two diameters to the existing piping or to run a new compliant line. When the tubes in place do not match, we replace them rather than force a fitting.\u003c\/p\u003e\n\n\u003ch3\u003e71 lb: plan for solid support\u003c\/h3\u003e\n\u003cp\u003eA 71 lb cabinet calls for a plenum in good shape and a support that will not give way over time. We check the rigidity of the sheet metal, the alignment with the furnace and the way the mass is distributed. A coil that works every day, with condensate collecting on it, deserves a well-shimmed mounting.\u003c\/p\u003e\n\u003cp\u003eIt takes two people to handle. We plan the basement delivery accordingly and protect the route from the door to the mechanical room.\u003c\/p\u003e\n\n\u003ch3\u003eThe N shape explained without jargon\u003c\/h3\u003e\n\u003cp\u003eThree faces of fins arranged in a zigzag, rather than two meeting at a point: that is the N-coil. It fits in a shorter cabinet than an A-coil. That choice makes sense when the plenum is low or when a duct, a beam or a ceiling limits the available height.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer lists multi-position installation: upflow, downflow, horizontal left or right. The expansion valve is a TXV.\u003c\/p\u003e\n\n\u003ch3\u003eThe DRBEF2421HTANMC data sheet at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal capacity: 2 tons (24,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003eExpansion valve: TXV;\u003c\/li\u003e\n\u003cli\u003eConnections: 3\/8 in liquid, 7\/8 in suction;\u003c\/li\u003e\n\u003cli\u003eCondensate: two 3\/4 in NPT connections;\u003c\/li\u003e\n\u003cli\u003eNet weight: 71 lb;\u003c\/li\u003e\n\u003cli\u003eSafety: A2L sensor and mitigation board in a single housing, factory-installed on models without the L suffix; temporary shutdown of the outdoor unit if excess refrigerant is detected; compatible with any 24 V thermostat;\u003c\/li\u003e\n\u003cli\u003eManufacturer's warranty: ten years on parts, conditional and with registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eChoose it, or look elsewhere in the series?\u003c\/h3\u003e\n\u003cp\u003eA few pointers drawn from the DRBEF series data sheets:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSame capacity, same shape:\u003c\/strong\u003e the DRBEF2421MTANMC is also a 2-ton \"N\", with no width listed on its data sheet. Its weight and connection values differ; we compare the two data sheets with you;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eKnown width of 17-1\/2 in:\u003c\/strong\u003e the DRBEF2417MTANMC and DRBEF2417STANMC give it, which makes it easier to fit a narrow furnace;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDifferent shape:\u003c\/strong\u003e the DRBEF2414STAAMC is an \"A\";\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMore capacity:\u003c\/strong\u003e the 3-ton models, such as the DRBEF3621HTAAMC or DRBEF3621MTANMC, are for larger homes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf your home is modest but the existing piping is already large-gauge, or if it will be redone, this model holds its own very well.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the coil does through the seasons\u003c\/h3\u003e\n\u003cp\u003eIn summer, the refrigerant boils inside the tubes and picks up heat from the air passing through them. That air, cooled and dehumidified, goes back into the ducts. In winter, with a heat pump, the cycle reverses and the heat collected outside is delivered to the house. The furnace keeps its filters, its blower and its backup role for the harshest cold.\u003c\/p\u003e\n\u003cp\u003eA coil has no efficiency rating of its own. The match and its AHRI number carry the SEER2, EER2 and HSPF2 ratings. We check that number before any order.\u003c\/p\u003e\n\n\u003ch3\u003eThe installation, step by step\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAssessment of the furnace, the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003eSetting the coil in the plenum, with an insulated transition on site if needed;\u003c\/li\u003e\n\u003cli\u003eBrazed refrigerant piping, nitrogen leak test, vacuum;\u003c\/li\u003e\n\u003cli\u003eConnecting the drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003eStart-up and airflow adjustment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBrazing, vacuum pulling and electrical connections are done under RBQ licence 5645-9605-01. Our family-run heating and cooling company has been in Montreal for more than fifteen years.\u003c\/p\u003e\n\n\u003ch3\u003eThe final look before ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe outdoor unit must run on R-454B, like the coil;\u003c\/li\u003e\n\u003cli\u003eThe furnace width must be checked before ordering;\u003c\/li\u003e\n\u003cli\u003eThe blower must deliver the system's airflow;\u003c\/li\u003e\n\u003cli\u003eIncentives depend on the complete system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eBrazing, nitrogen, vacuum: the three steps that make it last\u003c\/h3\u003e\n\u003cp\u003eRefrigerant fittings are brazed under a light flow of nitrogen, so that the inside of the tube stays clean. Then we pressurize the line to look for the slightest leak, and pull a vacuum to remove air and moisture before opening the refrigerant.\u003c\/p\u003e\n\u003cp\u003eThese steps are more demanding on a large-diameter suction tube, because the surfaces to heat and insulate are larger. We allow the time needed, and we skip no step to save an hour.\u003c\/p\u003e\n\u003cp\u003eFinally, we insulate the suction line along its whole visible length. A cold, bare tube drips in summer, and a dripping tube eventually stains a ceiling or a wall.\u003c\/p\u003e\n\u003ch3\u003eWhy the suction line belongs in a quote\u003c\/h3\u003e\n\u003cp\u003eA serious quote states the diameter of the connections and the nature of the piping. That lets you compare two offers on the same basis: one may include a new line, the other may reuse the existing one. Ask for this information in writing; it often explains part of the price gap between two contractors.\u003c\/p\u003e\n\u003ch3\u003eIncentive and paperwork\u003c\/h3\u003e\n\u003cp\u003eEligibility for Hydro-Québec programs, including LogisVert, is determined on the matched system, not on the coil alone. We check the official list according to the installation date, then tell you what applies to your project.\u003c\/p\u003e\n\n\u003ch3\u003eAbout the brand\u003c\/h3\u003e\n\u003cp\u003eDurastar is the heating and cooling brand of Ferguson, which Wolseley distributes in Canada. Its DRBEF coils running on R-454B are installed on a furnace to go with Durastar heat pumps and central air conditioners.\u003c\/p\u003e\n\n\u003ch3\u003eA word on maintenance after installation\u003c\/h3\u003e\n\u003cp\u003eA coil of this weight benefits from a periodic check: clean fins, a pan free of deposits, a drain that runs freely. We give you a simple list of what to look at yourself and what calls for a technician. A check visit before summer can catch a weeping joint or an overloaded filter.\u003c\/p\u003e\n\n\u003ch2\u003eRequest your estimate\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Durastar system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Durastar","offers":[{"title":"Default Title","offer_id":68402711724324,"sku":"DRBEF2421HTANMC","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_DURASTAR_DRBEF_DRBEF2421HTANMC_00_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765885","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-durastar-drbef2421htanmc-n-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}