{"product_id":"serpentin-devaporateur-durastar-drbef3621htaamc-a-3-tonnes","title":"DURASTAR DRBEF3621HTAAMC Evaporator A-Coil | 3 Tons","description":"\u003ch2\u003eDRBEF3621HTAAMC: the 3-ton A-coil, 76 lb, for the two-storey home with an upflow furnace\u003c\/h2\u003e\n\u003cp\u003eThe large suburban two-storey home has its habits: a basement furnace that blows upward, a duct network serving two floors, and summers when the upper floor turns into a steam room. For that profile, the \u003cstrong\u003eDurastar DRBEF3621HTAAMC evaporator coil\u003c\/strong\u003e has good arguments. It is a 3-ton (36,000 BTU\/h) A-coil with a cabinet, so a cased coil, running on \u003cstrong\u003eR-454B refrigerant\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWe install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, in homes where central air conditioning must reach the upper floor without overloading the main floor.\u003c\/p\u003e\n\n\u003ch3\u003eA 3-ton size for a multi-storey home\u003c\/h3\u003e\n\u003cp\u003eThe larger the home, the more air there is to treat, and the more generous the coil's heat-exchange surface must be. The 3-ton size is there for that. It suits many two-level suburban homes with a basement, provided the load calculation confirms it.\u003c\/p\u003e\n\u003cp\u003eWe insist on that calculation. If your home needs less, we steer you to a 2-ton model; if it needs more, we tell you that too. In every case, the quote is based on the house, not on what is in stock.\u003c\/p\u003e\n\n\u003ch3\u003eWhy an \"A\" on an upflow furnace\u003c\/h3\u003e\n\u003cp\u003eThe A-coil is made of two fin plates leaning together and joined at the top. Air arrives from below, rises through the centre and passes through both faces. On an upflow furnace, it is a natural arrangement, one we know well. It needs a little more height above the furnace than an N-coil: so we measure the plenum space before proposing it.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer lists multi-position installation: upflow, downflow, horizontal left or right. The expansion valve is a TXV.\u003c\/p\u003e\n\n\u003ch3\u003eThe weight: 76 lb to carry and to support\u003c\/h3\u003e\n\u003cp\u003eThe listed net weight is 76 lb. That means two technicians for handling and a plenum that must be solid. We check the sheet metal, the supports and the alignment, then seal all the joints.\u003c\/p\u003e\n\u003cp\u003eThat mass has an advantage: a sturdy cabinet stands up better to years of use and condensation. It only requires preparing the route through the house well, particularly in a narrow basement staircase.\u003c\/p\u003e\n\n\u003ch3\u003e7\/8 in connections: the piping follows\u003c\/h3\u003e\n\u003cp\u003eThis coil's connections are 3\/8 in for liquid and 7\/8 in for suction. That suction line calls for careful brazing, a good nitrogen test and complete insulation. We check the existing piping: if it is not suitable, we run a new line.\u003c\/p\u003e\n\n\u003ch3\u003eWhat to remember from the data sheet\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel DRBEF3621HTAAMC, cased coil, DRBEF series;\u003c\/li\u003e\n\u003cli\u003eNominal capacity: 3 tons (36,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003eR-454B refrigerant; TXV expansion valve;\u003c\/li\u003e\n\u003cli\u003eConnections: 3\/8 in liquid, 7\/8 in suction;\u003c\/li\u003e\n\u003cli\u003eCondensate: two 3\/4 in NPT connections;\u003c\/li\u003e\n\u003cli\u003eNet weight: 76 lb;\u003c\/li\u003e\n\u003cli\u003eBuilt-in leak detection: A2L sensor and mitigation board, factory-installed on models without the L suffix, pausing the outdoor unit if excess refrigerant is detected, compatible with any 24 V thermostat;\u003c\/li\u003e\n\u003cli\u003eConditional 10-year parts warranty, with registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShould you choose this one over another 3-ton?\u003c\/h3\u003e\n\u003cp\u003eThe series offers five 3-ton coils. Here is how to tell them apart from the published data:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eThe \"A\" coils:\u003c\/strong\u003e the DRBEF3621HTAAMC and DRBEF3621MTAAMC share the same shape and the same data sheet values; we help you choose according to the reference your match calls for;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eThe \"N\" coils:\u003c\/strong\u003e the DRBEF3617STANMC, DRBEF3621MTANMC and DRBEF3621STANMC, lower, for a plenum with limited height;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDesignated match:\u003c\/strong\u003e the DRBEF3617STANMC and DRBEF3621STANMC are tied to the DRHP15B36AJ2AN unit;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWidth of 17-1\/2 in:\u003c\/strong\u003e published only for the DRBEF3617STANMC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf your furnace has height to spare and you want the classic A shape, this model fits well.\u003c\/p\u003e\n\n\u003ch3\u003eCooling and heating: how the roles are split\u003c\/h3\u003e\n\u003cp\u003eIn summer, the refrigerant evaporating in the coil removes heat from the air and condenses the moisture. Upstairs, that means bedrooms where you sleep better. In winter, with a heat pump, the cycle reverses and the same ducts carry heated air. The furnace takes over below the temperature threshold we set with you.\u003c\/p\u003e\n\u003cp\u003eThe coil has no efficiency rating of its own: the SEER2, EER2 and HSPF2 ratings belong to the certified match, and an AHRI number ties them together.\u003c\/p\u003e\n\n\u003ch3\u003eMatching with the outdoor unit\u003c\/h3\u003e\n\u003cp\u003eThis coil is matched with a Durastar outdoor unit of the same capacity and the same refrigerant. We check the exact match and its AHRI number in the directory before ordering. The outdoor heat pump and the coil are installed together, with the same refrigerant.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation day\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAssessment of the furnace, the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003eInstalling the coil and sealing the duct connections;\u003c\/li\u003e\n\u003cli\u003eInstalling the outdoor unit, brazing, nitrogen test, vacuum;\u003c\/li\u003e\n\u003cli\u003eConnecting the drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003eStart-up, airflow adjustment, walk-through.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe work under RBQ licence 5645-9605-01. AirGreen, a family-run heating and cooling company, has been based in Montreal for more than fifteen years.\u003c\/p\u003e\n\n\u003ch3\u003eThe usual checks\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSame refrigerant on both sides: R-454B;\u003c\/li\u003e\n\u003cli\u003eEnough height above the furnace for an \"A\";\u003c\/li\u003e\n\u003cli\u003eFurnace width confirmed before ordering;\u003c\/li\u003e\n\u003cli\u003eBlower able to deliver the system's airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHydro-Québec incentives\u003c\/h3\u003e\n\u003cp\u003eEligibility for LogisVert and the other programs depends on the complete system, not on the coil alone. We check the official list according to the installation date and tell you what applies to your project.\u003c\/p\u003e\n\n\u003ch3\u003eThe brand\u003c\/h3\u003e\n\u003cp\u003eDurastar is the heating and cooling brand of Ferguson, distributed in Canada by Wolseley. Its DRBEF coils running on R-454B go with the brand's heat pumps and central air conditioners.\u003c\/p\u003e\n\n\u003ch3\u003eComfort upstairs, a detail that changes everything\u003c\/h3\u003e\n\u003cp\u003eIn a multi-storey home, a single thermostat does not tell the whole story. Warm air rises, the upstairs bedroom is often the warmest, and the basement room the coolest. A well-set airflow and balanced registers help spread the comfort. We check these settings at start-up and adjust them with you on the first hot day.\u003c\/p\u003e\n\n\u003ch3\u003ePlanning maintenance for a sturdy cabinet\u003c\/h3\u003e\n\u003cp\u003eA coil installed on a furnace is cleaned from the plenum. We leave convenient access and show you where the pan is. The filter remains the most important element: clean, it protects the fins from dust and extends the life of the blower.\u003c\/p\u003e\n\n\u003cp\u003ePlan for a check before the cooling season and another before heating. Our team serves Montreal, Laval, Longueuil, the North Shore and the South Shore, and schedules these visits with you according to your calendar, so the system is ready before the first big heat.\u003c\/p\u003e\n\n\u003ch2\u003eRequest your estimate\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Durastar system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Durastar","offers":[{"title":"Default Title","offer_id":68402716541220,"sku":"DRBEF3621HTAAMC","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_DURASTAR_DRBEF_DRBEF3621HTAAMC_00_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765967","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-durastar-drbef3621htaamc-a-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}