{"product_id":"serpentin-devaporateur-durastar-drbef3621meaamc-a-3-tonnes","title":"DURASTAR DRBEF3621MEAAMC Evaporator A-Coil | 3 Tons","description":"\u003ch2\u003eThree tons, A-coil shape: the DRBEF3621MEAAMC for the mid-sized home\u003c\/h2\u003e\n\u003cp\u003eBetween the small bungalow and the large multi-storey property, there is a wide range of mid-sized homes: suburban cottages, split-levels, semi-detached houses with a finished basement. For them, the 3-ton size (36,000 BTU\/h) is often the starting point of the discussion. The \u003cstrong\u003eDRBEF3621MEAAMC\u003c\/strong\u003e is a Durastar evaporator coil of that capacity, A-shaped, cased, running on \u003cstrong\u003eR-454B refrigerant\u003c\/strong\u003e. AirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eThree common mistakes this size helps you avoid\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFirst mistake: choosing by floor area alone.\u003c\/strong\u003e Two homes with the same floor area can call for different capacities depending on insulation, windows and orientation. We do a load calculation, not a rule of thumb.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSecond mistake: neglecting the blower.\u003c\/strong\u003e At 3 tons, the airflow the coil requires is greater than with a small model. If the furnace blower can't deliver it, the coil may ice up or the house will lack comfort. We check before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThird mistake: buying a coil without thinking about the outdoor unit.\u003c\/strong\u003e The two parts are a couple. The outdoor unit must have the same capacity and run on R-454B.\u003c\/p\u003e\n\n\u003ch3\u003eThe A shape, its logic and its footprint\u003c\/h3\u003e\n\u003cp\u003eThe A-coil rests on two sloped faces that join at the top. Air rises along the furnace axis and passes through each face. It is a classic geometry for upflow furnaces, and it suits mechanical rooms that offer a bit of height above the unit.\u003c\/p\u003e\n\u003cp\u003eIf clearance is limited, the N version of the same capacity, the DRBEF3621MEANMC, offers a shorter cabinet. We help you decide by measuring the real space.\u003c\/p\u003e\n\n\u003ch3\u003eA coil for air conditioning and heating at once\u003c\/h3\u003e\n\u003cp\u003eOn its own, a coil produces nothing: the outdoor unit supplies the refrigerant, and the coil exchanges heat with your home's air. With a central air conditioner, it cools in summer. With a heat pump, it also heats in winter, using the same ducts. The furnace keeps its blower and serves as backup during the deep cold.\u003c\/p\u003e\n\u003cp\u003eThe condensation water that forms on the coil runs into the pan and leaves through the two 3\/4 in NPT condensate connections. The metering device is an EEV.\u003c\/p\u003e\n\n\u003ch3\u003eDRBEF3621MEAAMC data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emanufacturer and range: Durastar, DRBEF;\u003c\/li\u003e\n\u003cli\u003etype: cased A-coil;\u003c\/li\u003e\n\u003cli\u003esize: 3 tons, 36,000 BTU\/h;\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in for liquid, 7\/8 in for suction;\u003c\/li\u003e\n\u003cli\u003epositions: upflow, downflow, horizontal left or right;\u003c\/li\u003e\n\u003cli\u003enet weight: 76 lb;\u003c\/li\u003e\n\u003cli\u003ewarranty: conditional 10-year parts warranty, with registration (sheet CDS-228);\u003c\/li\u003e\n\u003cli\u003eleak detection: factory-installed A2L sensor and mitigation board, pausing the outdoor unit if excess refrigerant is detected, compatible with any 24 V thermostat.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEfficiency: reading the ratings correctly\u003c\/h3\u003e\n\u003cp\u003eThe coil has no rating on its own. SEER2, EER2 and HSPF2 values describe a system, that is, a specific outdoor unit linked to a specific coil, with an AHRI number. Durastar states that its DRHP14B and DRHP15B heat pumps, from the DRAC series on R-454B and with a two-stage compressor, pair with DRBEF coils; the standard pairings show a SEER2 of 15.2, an EER2 of 11.7 and an HSPF2 of 7.8. Only certain TXV coils are listed on ENERGY STAR, with ratings for the American market.\u003c\/p\u003e\n\u003cp\u003eThis detail matters when you compare two quotes: always ask for the AHRI number.\u003c\/p\u003e\n\n\u003ch3\u003eHow this model compares with the series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eTo the DRBEF3621MEANMC\u003c\/strong\u003e: same capacity and same connections; the latter is an N-coil, so shorter.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eTo the 2-ton models\u003c\/strong\u003e (DRBEF2421HEAAMC, DRBEF2421HEANMC, DRBEF2421MEANMC, DRBEF2417SEANMC): lower capacity, for small homes or a plex unit.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eTo the DRBEF4821SEAAMC\u003c\/strong\u003e: same A shape, but 4 tons, for a larger home or higher airflow.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eTo the 5-ton models\u003c\/strong\u003e (DRBEF6021SEAAMC, DRBEF6024SEANMC and DRBEF6024STANMC): for the largest properties.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMetering device\u003c\/strong\u003e: this model has an EEV, like most of its neighbours; only the DRBEF6024STANMC has a TXV.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHumidity, noise, comfort: what we really look at\u003c\/h3\u003e\n\u003cp\u003eMany homeowners judge an air conditioning system on a single criterion: the thermostat temperature. Yet the feeling of comfort also comes from the humidity of the air. A properly sized coil runs long enough to dry the air, whereas an oversized coil short-cycles and leaves an unpleasant clamminess. That is one of the reasons we don't sell one size up \"just in case.\"\u003c\/p\u003e\n\u003cp\u003eAir noise in the ducts is another clue. If the vents whistle, it is often because the ducts or filters are limiting the flow. We take that into account, because a 3-ton system only delivers its full effect if the air circulates freely.\u003c\/p\u003e\n\n\u003ch3\u003eWhat remains of your current installation\u003c\/h3\u003e\n\u003cp\u003eIn most cases, the furnace, filters and ducts stay. What changes: the coil in the plenum, the outdoor unit, the refrigerant piping, the drain and the thermostat. It is a relatively limited renovation that requires no demolition and no new ducts in the walls. It still comes with a check of the electrical panel, because the heat pump or the outdoor air conditioner needs its own circuit.\u003c\/p\u003e\n\n\u003ch3\u003eAn installation carried out by a single team\u003c\/h3\u003e\n\u003cp\u003eAirGreen has been a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company in Montreal for more than fifteen years, and we work under RBQ licence 5645-9605-01. The same people handle the refrigeration, ventilation and electrical side of your project.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eMeasuring the furnace, checking the blower and the electrical panel.\u003c\/li\u003e\n\u003cli\u003eSetting the coil in the plenum, sealing the duct connections, insulated transition if the width differs.\u003c\/li\u003e\n\u003cli\u003ePlacing the outdoor unit on its base, brazed piping, nitrogen pressure test, vacuum.\u003c\/li\u003e\n\u003cli\u003eConnecting the drain and the thermostat.\u003c\/li\u003e\n\u003cli\u003eCommissioning, airflow adjustment, demonstration of the controls.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eQuestions to ask before ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIs the furnace width compatible with the cabinet? We measure it at your home.\u003c\/li\u003e\n\u003cli\u003eDoes the blower reach the airflow a 3-ton system calls for?\u003c\/li\u003e\n\u003cli\u003eDoes the load calculation confirm this size?\u003c\/li\u003e\n\u003cli\u003eDoes the outdoor unit use R-454B?\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA word about the warranty\u003c\/h3\u003e\n\u003cp\u003eDurastar offers a conditional 10-year parts warranty, with registration (sheet CDS-228). The word \"conditional\" matters: the unit must be registered, and the installation must be done to the rules. We handle this step with you at commissioning, so the registration deadline isn't missed.\u003c\/p\u003e\n\n\u003ch3\u003eHydro-Québec incentives\u003c\/h3\u003e\n\u003cp\u003eThe programs apply to the complete system, not the coil alone. We consult the official list at the time of the quote, taking the installation date into account, then tell you what applies to your file.\u003c\/p\u003e\n\n\u003ch3\u003eNext step: a visit\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate. We measure the furnace, check the electrical service and give you a written quote for the complete Durastar system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Durastar","offers":[{"title":"Default Title","offer_id":68402718834980,"sku":"DRBEF3621MEAAMC","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_DURASTAR_DRBEF_DRBEF3621MEAAMC_00_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765969","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-durastar-drbef3621meaamc-a-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}