{"product_id":"serpentin-devaporateur-durastar-drbef3621mtaamc-a-3-tonnes","title":"DURASTAR DRBEF3621MTAAMC Evaporator A-Coil | 3 Tons","description":"\u003ch2\u003eDRBEF3621MTAAMC: choosing the coil position, from vertical plenum to horizontal attic\u003c\/h2\u003e\n\u003cp\u003eThe same furnace is not installed the same way in every home. Some blow upward from a basement. Others blow downward from an attic or a crawl space. Still others lie on their side in a ceiling space. The \u003cstrong\u003eDurastar DRBEF3621MTAAMC evaporator coil\u003c\/strong\u003e has been published by the manufacturer as multi-position: upflow, downflow, horizontal left or horizontal right.\u003c\/p\u003e\n\u003cp\u003eIt is a 3-ton (36,000 BTU\/h) A-coil with a cabinet, so a cased coil, using \u003cstrong\u003eR-454B refrigerant\u003c\/strong\u003e. We install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eFour positions, four questions to ask\u003c\/h3\u003e\n\u003cp\u003eBefore choosing a coil, we look at how the furnace is installed:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eUpflow:\u003c\/strong\u003e the furnace is in the basement and blows upward; the coil goes on top;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDownflow:\u003c\/strong\u003e the furnace is up high and blows downward; the coil goes below the plenum;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHorizontal left:\u003c\/strong\u003e the furnace lies on its side and the air moves in one direction;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHorizontal right:\u003c\/strong\u003e the furnace lies on its side and the air moves in the other direction.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe DRBEF3621MTAAMC is listed for all four cases. We confirm on site that your configuration is one of them and we arrange the drain accordingly.\u003c\/p\u003e\n\n\u003ch3\u003eThe condensate drain rules\u003c\/h3\u003e\n\u003cp\u003eA coil at work produces water. In a horizontal position especially, the slope of the pan and the direction of the drain decide everything: if the water does not leave, it overflows. This model has two 3\/4 in NPT condensate connections. We use the one that matches the chosen position and cap the other neatly.\u003c\/p\u003e\n\u003cp\u003eIn an attic or a ceiling space, we provide a safety pan and an exit path, so that a possible leak does not stain a ceiling.\u003c\/p\u003e\n\n\u003ch3\u003eAn A-coil, with the weight that goes with it\u003c\/h3\u003e\n\u003cp\u003eThe two inclined faces, joined at the top, form the letter A. It is a classic and sturdy configuration. The listed net weight is 76 lb, which calls for two technicians and a solid support. We check the plenum, its joints and its fastening before proceeding.\u003c\/p\u003e\n\u003cp\u003eThe expansion valve is a TXV, which regulates the refrigerant flow according to the load of the air to be treated.\u003c\/p\u003e\n\n\u003ch3\u003eThe connections and safety\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLiquid: 3\/8 in; suction: 7\/8 in;\u003c\/li\u003e\n\u003cli\u003eLeak detection: A2L sensor and mitigation board in a single housing, factory-installed on models without the L suffix; if excess refrigerant is detected, the outdoor unit stops temporarily;\u003c\/li\u003e\n\u003cli\u003eCompatible with any 24 V thermostat.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eData sheet summary\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel: DRBEF3621MTAAMC, DRBEF series;\u003c\/li\u003e\n\u003cli\u003eType: cased evaporator coil;\u003c\/li\u003e\n\u003cli\u003eNominal size: 3 tons, or 36,000 BTU\/h;\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003eNet weight: 76 lb;\u003c\/li\u003e\n\u003cli\u003eConditional 10-year parts warranty, with registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA twin in the series: the DRBEF3621HTAAMC\u003c\/h3\u003e\n\u003cp\u003eThe data sheets of the DRBEF3621MTAAMC and the DRBEF3621HTAAMC list the same values: 3 tons, A shape, R-454B, TXV, 3\/8 in and 7\/8 in connections, 76 lb. They differ by their part reference. We ask the manufacturer to confirm the exact correspondence between the reference and your match before placing the order; it is a quick check that avoids a return of equipment.\u003c\/p\u003e\n\u003cp\u003eFor the others, here is how to tell them apart:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eA 3-ton \"N\":\u003c\/strong\u003e the DRBEF3617STANMC, DRBEF3621MTANMC and DRBEF3621STANMC, lower;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eA width of 17-1\/2 in:\u003c\/strong\u003e published for the DRBEF3617STANMC;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eLess capacity:\u003c\/strong\u003e the 2-ton models, including the DRBEF2414STAAMC, also an \"A\".\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe coil's role in your system\u003c\/h3\u003e\n\u003cp\u003eIt receives refrigerant from the outdoor unit and cools the air moving through your ducts. With a heat pump, it also gives back heat from outdoors in winter. It has no efficiency rating of its own: the published values belong to the certified match, identified by an AHRI number.\u003c\/p\u003e\n\u003cp\u003eThe outdoor unit must have the same capacity and the same refrigerant. We look up its number in the directory before the order.\u003c\/p\u003e\n\n\u003ch3\u003eOur installation method\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTechnical visit: furnace, blower, electrical panel, installation position;\u003c\/li\u003e\n\u003cli\u003eInstalling the coil in the chosen position, with sealed joints;\u003c\/li\u003e\n\u003cli\u003eOutdoor unit on a pad or bracket; brazed piping; nitrogen test; vacuum;\u003c\/li\u003e\n\u003cli\u003eCondensate drain and thermostat connected;\u003c\/li\u003e\n\u003cli\u003eStart-up, airflow adjustment, explanations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRBQ licence 5645-9605-01 covers our refrigeration, ventilation and electrical work. AirGreen, a family-run heating and cooling company, has been based in Montreal for more than fifteen years.\u003c\/p\u003e\n\n\u003ch3\u003eBefore ordering, let's check together\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSame refrigerant, R-454B, for the coil and the outdoor unit;\u003c\/li\u003e\n\u003cli\u003eFurnace installation position confirmed;\u003c\/li\u003e\n\u003cli\u003eFurnace width checked;\u003c\/li\u003e\n\u003cli\u003eBlower able to deliver the required airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec programs, notably LogisVert, take the matched system into account, not the coil alone. We check the official list according to the installation date and tell you what applies.\u003c\/p\u003e\n\n\u003ch3\u003eDurastar\u003c\/h3\u003e\n\u003cp\u003eDurastar is the heating and cooling brand of Ferguson, distributed in Canada by Wolseley. DRBEF coils running on R-454B are installed on a furnace and go with the brand's heat pumps and central air conditioners.\u003c\/p\u003e\n\n\u003ch3\u003eIf your furnace is in a tight space\u003c\/h3\u003e\n\u003cp\u003eA low attic, a crawl space or a utility closet needs a little preparation: a clear path, lighting, a safe working floor. We come to look before quoting, take photos and tell you honestly whether access is workable. Better to know at the estimate than during the installation.\u003c\/p\u003e\n\n\u003ch3\u003eA concrete example: the attic furnace\u003c\/h3\u003e\n\u003cp\u003ePicture a home whose furnace is in the attic space, above the second floor, blowing downward into the ducts. In that case, the coil goes in the downflow position. The weight of the cabinet then rests on the structure of the unit, which must be solid, and the condensate drain must run down without ever risking an overflow onto a ceiling.\u003c\/p\u003e\n\u003cp\u003eWe provide a safety pan, a secondary drain when useful, and access for maintenance. The attic floor is made safe so the work is done cleanly and without risk. This type of job takes a bit more preparation, but it goes very well when everything has been planned during the visit.\u003c\/p\u003e\n\u003ch3\u003eWhat the configuration changes at the thermostat\u003c\/h3\u003e\n\u003cp\u003eNothing changes for you. The thermostat controls the whole system the same way, whatever the position of the coil. You set the temperature, and the system takes care of the rest. The position is only a matter of installation.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation day, on the home side\u003c\/h3\u003e\n\u003cp\u003ePlan to clear the path to the furnace and put away whatever clutters the mechanical room. If a pet moves about freely, think about placing it in a room away from the work. The installation may require briefly shutting off the heat and the power; we warn you in advance and put everything back on before we leave.\u003c\/p\u003e\n\n\u003ch2\u003eBook your estimate appointment\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Durastar system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Durastar","offers":[{"title":"Default Title","offer_id":68402717262116,"sku":"DRBEF3621MTAAMC","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_DURASTAR_DRBEF_DRBEF3621MTAAMC_00_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765966","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-durastar-drbef3621mtaamc-a-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}