{"product_id":"serpentin-devaporateur-durastar-drbef3624mtanmc-n-3-tonnes","title":"DURASTAR DRBEF3624MTANMC Evaporator N-Coil | 3 Tons","description":"\u003ch2\u003eDRBEF3624MTANMC: the 3-ton N-coil, 24-1\/2 in wide, for the bungalow with a low furnace\u003c\/h2\u003e\n\u003cp\u003ePicture this: you go down to the basement with a contractor, a flashlight and a tape measure. In front of you are the furnace, a plenum with slightly crumpled sheet metal and, above it, a beam that leaves very little room to spare. That is exactly the kind of setting where the \u003cstrong\u003eDurastar DRBEF3624MTANMC evaporator coil\u003c\/strong\u003e fits. It belongs to the DRBEF series, it is N-shaped, it comes in its own cabinet, and it serves homes in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e that want central air conditioning or, with a heat pump, central heating through the existing ductwork.\u003c\/p\u003e\n\u003cp\u003eOn the spec sheet you will read three things: \u003cstrong\u003e3 tons\u003c\/strong\u003e (36,000 BTU\/h at the nominal size), a width of \u003cstrong\u003e24-1\/2 in\u003c\/strong\u003e and the \u003cstrong\u003eR-454B\u003c\/strong\u003e refrigerant. The rest of this page explains what those numbers mean in your home.\u003c\/p\u003e\n\n\u003ch3\u003eWhat an evaporator coil actually does\u003c\/h3\u003e\n\u003cp\u003ePeople talk a lot about the outdoor unit, because it is the one you can see. Yet half of the work happens indoors, in a box nobody looks at. The coil is a series of aluminum and copper tubes. In summer, the refrigerant evaporates inside it and absorbs heat from the air passing through; moisture condenses on the fins, drips into the pan and runs off to the drain. The air comes out cool and drier.\u003c\/p\u003e\n\u003cp\u003eWith a heat pump, the cycle reverses in winter: the coil becomes the place where the heat captured outdoors is released into the air of the house. One appliance, two seasons.\u003c\/p\u003e\n\n\u003ch3\u003eWhy the N shape matters here\u003c\/h3\u003e\n\u003cp\u003eA-coils are taller. The DRBEF3624MTANMC spreads its surfaces in a zigzag, with three faces, inside a cabinet that is less tall. As a result, it can slip into spaces where the height above the furnace is tight, under a beam or under pipes, for example. That is often the situation in older bungalows and single-storey homes in Longueuil or Montreal, where the basement was finished with a low ceiling.\u003c\/p\u003e\n\u003cp\u003eThe cabinet is insulated and delivered ready to install, which avoids building a box on site and reduces air leaks around the coil.\u003c\/p\u003e\n\n\u003ch3\u003eA width of 24-1\/2 in: the first measurement to take\u003c\/h3\u003e\n\u003cp\u003eBefore even talking about capacity, get out the tape measure. This coil is 24-1\/2 in wide, and that is the value to compare with the plenum of your furnace. If the gap is small, an insulated transition made on site takes care of it. That is precisely what our visit is for: measure, take notes and confirm before ordering. We never place an order hoping it will be close enough.\u003c\/p\u003e\n\u003cp\u003eAlso note the net weight, 83 lb. It is not a light package, but two installers can bring it downstairs without difficulty.\u003c\/p\u003e\n\n\u003ch3\u003eWhere the DRBEF3624MTANMC can be installed\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer states that it is multi-position: upflow, downflow, horizontal left or horizontal right. In plain terms, it follows your furnace, whether it blows upward, downward or sideways in an attic or a crawl space. The metering device is a TXV, a valve that adjusts the flow of refrigerant according to the load.\u003c\/p\u003e\n\u003cp\u003eTwo 3\/4 in NPT condensate connections let you choose the drain side that suits the plumbing in the room.\u003c\/p\u003e\n\n\u003ch3\u003eThree tons: for what kind of house?\u003c\/h3\u003e\n\u003cp\u003eThe 3-ton size matches what we see most often in a medium-sized single-family home: one storey or a storey and a half, a basement, and a furnace whose blower serves every room. If your ducts are short and clean, the coil and the blower work well together. If they are narrow or very long, we will see it at the visit, because a coil does not make up for a poorly sized air distribution system.\u003c\/p\u003e\n\u003cp\u003eOne tip from the field: if you hesitate between this size and the next, look at how the house behaves today. Upstairs bedrooms that stay warm all night are not always fixed by going up a size; sometimes it is the airflow that needs a second look.\u003c\/p\u003e\n\n\u003ch3\u003eMatching: the coil never works alone\u003c\/h3\u003e\n\u003cp\u003eThe DRBEF3624MTANMC connects to a Durastar outdoor unit of the same capacity and the same refrigerant. It has no efficiency rating of its own: the published ratings belong to the matched system, with its AHRI number. That number is what lets you compare two quotes or confirm that a system appears on a rebate list. We check it before ordering, so the figures advertised are the ones you actually get.\u003c\/p\u003e\n\u003cp\u003eAnother point to remember: the old air conditioner is generally not kept. The coil runs on R-454B and must be installed at the same time as the planned outdoor unit.\u003c\/p\u003e\n\n\u003ch3\u003eChoosing between the 3-ton and the other DRBEF coils\u003c\/h3\u003e\n\u003cp\u003eIn the series, the 3-ton is the smallest. Here is how it compares:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe 3.5-ton models, DRBEF4221HTAAMC and DRBEF4221STAAMC, are A-coils in a larger size; they suit homes whose furnace has some height to offer.\u003c\/li\u003e\n\u003cli\u003eThe 4-ton models include A-coil versions (DRBEF4821HTAAMC, DRBEF4821STAAMC) and N-coil versions (DRBEF4821STANMC, DRBEF4824MTANMC, DRBEF4824STANMC).\u003c\/li\u003e\n\u003cli\u003eThe 5-ton models are the DRBEF6021STAAMC, an A-coil, and the DRBEF6024HTANMC, an N-coil.\u003c\/li\u003e\n\u003cli\u003eAmong those with a width of 24-1\/2 in, like this one, you will also find the DRBEF4824MTANMC, DRBEF4824STANMC and DRBEF6024HTANMC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThey all share R-454B and a TXV. What changes is the capacity, the shape and the matching. If your furnace has the right width, the ceiling is low and the house is medium-sized, the DRBEF3624MTANMC is the logical starting point.\u003c\/p\u003e\n\n\u003ch3\u003eWhat to know about refrigerant safety\u003c\/h3\u003e\n\u003cp\u003eR-454B belongs to the category of mildly flammable refrigerants, which is why a detector is included. This model comes with a factory-installed module as standard, combining a sensor and a control board. If it detects excess refrigerant, it pauses the outdoor unit. It works with any 24 V thermostat, and the manufacturer's CDS-228 sheet gives the details. The manufacturer also offers a conditional 10-year parts warranty, subject to registration.\u003c\/p\u003e\n\n\u003ch3\u003eOur installation, from the visit to start-up\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-run \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company based in Montreal for more than fifteen years; refrigeration, ventilation and electrical work are done under RBQ licence 5645-9605-01. For this coil, here is how it goes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ewe measure the furnace, assess the blower and look at the electrical panel;\u003c\/li\u003e\n\u003cli\u003ewe install the coil in the plenum, add an insulated transition if needed and seal the joints;\u003c\/li\u003e\n\u003cli\u003ewe set the outdoor unit on a stand, braze the piping, pressure-test with nitrogen and pull a vacuum;\u003c\/li\u003e\n\u003cli\u003ewe connect the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ewe start the system, adjust the airflow and show you how to use it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eRebates, without bad surprises\u003c\/h3\u003e\n\u003cp\u003eEligibility depends on the complete system, never on the coil alone. Hydro-Québec programs change and depend on the installation date; we consult the official list at the time of the quote and tell you what applies to your project. If the chosen match is on it, we help you put the application together.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently asked questions about the DRBEF3624MTANMC\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan it heat my home?\u003c\/strong\u003e Yes, when it is paired with a heat pump. With a central air conditioner, it provides cooling only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs my furnace still useful?\u003c\/strong\u003e Yes. It keeps its blower and takes over as backup heat when the outdoor temperature drops below the threshold we set with you.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat if the width does not match?\u003c\/strong\u003e We build a custom insulated transition.\u003c\/p\u003e\n\n\u003ch3\u003eNext step: an estimate at your home\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWe come to your home, free of charge, to measure the furnace, check the electrical service and write up a written quote for the complete Durastar system. To spread out the cost, \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Durastar","offers":[{"title":"Default Title","offer_id":68402717163812,"sku":"DRBEF3624MTANMC","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_DURASTAR_DRBEF_DRBEF3624MTANMC_00_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765967","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-durastar-drbef3624mtanmc-n-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}