{"product_id":"serpentin-devaporateur-durastar-drbef4821stanmc-n-4-tonnes","title":"DURASTAR DRBEF4821STANMC Evaporator N-Coil | 4 Tons","description":"\u003ch2\u003eDRBEF4821STANMC: the 4-ton N-coil, matched to face the Quebec winter\u003c\/h2\u003e\n\u003cp\u003eMost coils come with a capacity and a shape. This one arrives with a named partner: the \u003cstrong\u003eDRHP15B42AJ2AN\u003c\/strong\u003e outdoor unit. The \u003cstrong\u003eDurastar DRBEF4821STANMC evaporator coil\u003c\/strong\u003e, N-shaped, cased, with a nominal size of \u003cstrong\u003e4 tons\u003c\/strong\u003e (48,000 BTU\/h) and \u003cstrong\u003eR-454B\u003c\/strong\u003e refrigerant, is one of the two matches that Durastar publishes as certified for cold climates. For a home in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e or the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e where the thermometer stays below zero for weeks, that detail changes how you read the spec sheet.\u003c\/p\u003e\n\n\u003ch3\u003eWhat \"cold climate\" means here\u003c\/h3\u003e\n\u003cp\u003eIn the manufacturer's documentation, the match of the DRBEF4821STANMC with the DRHP15B42AJ2AN heat pump shows (HSPF2 8.1, 40,000 BTU\/h at -8 °C). These values describe the system, not the coil alone. The SEER2 published for this system is 15.2. The AHRI numbers that correspond to this combination are 216686804, 216686811.\u003c\/p\u003e\n\u003cp\u003eWhy do these numbers matter? Because they link a specific coil to a specific outdoor unit. It is the only way to prove, in a public directory, that the advertised ratings really apply to what is installed in your home.\u003c\/p\u003e\n\n\u003ch3\u003eA heat pump that works in winter, a furnace that stands watch\u003c\/h3\u003e\n\u003cp\u003eEven with a match certified for the cold, the furnace does not disappear. It keeps its blower, its filters and its ducts, and it stays ready to take over the heating when the outdoor temperature drops below the threshold we program with you. This division of labour, the heat pump for most of the season and the furnace for the harshest nights, is what makes the project reasonable for a home that is already equipped.\u003c\/p\u003e\n\u003cp\u003eIf you currently heat with electricity, the difference is telling. An electric furnace converts each kilowatt-hour into an equivalent amount of heat. A heat pump moves heat from outdoors, and in mild weather provides roughly two to three times the energy it consumes; that efficiency drops with the cold, which is why a match designed for low temperatures is worth having.\u003c\/p\u003e\n\n\u003ch3\u003eWhy the N shape?\u003c\/h3\u003e\n\u003cp\u003eThree faces in a zigzag, in a cabinet less tall than that of an A-coil. It is the solution when the space above the furnace is restricted: a beam, piping, a finished ceiling. The insulated cabinet is delivered ready to install. The positions allowed by the manufacturer are: upflow, downflow, horizontal left or horizontal right. The TXV regulates the refrigerant flow.\u003c\/p\u003e\n\u003cp\u003eThis model is the lightest of its size: 71 lb net weight, less than each of the other 4-tons. The connections are 3\/8 in (liquid) and 7\/8 in (suction), with two 3\/4 in NPT condensate connections.\u003c\/p\u003e\n\n\u003ch3\u003eA width to confirm\u003c\/h3\u003e\n\u003cp\u003eUnlike the DRBEF4824 models, this coil has no published width in our sheet. So we measure the furnace during the visit and confirm that the plenum is suitable. If needed, an insulated transition is built on site.\u003c\/p\u003e\n\n\u003ch3\u003eDRBEF4821STANMC or DRBEF4824STANMC?\u003c\/h3\u003e\n\u003cp\u003eBoth are 4-ton N-coils, both are certified for cold climates, and both appear in Durastar's standard-efficiency ENERGY STAR list (4821S and 4824S), with ratings published for the US market. Here is what sets them apart:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethe DRBEF4821STANMC weighs 71 lb and is matched to the DRHP15B42AJ2AN;\u003c\/li\u003e\n\u003cli\u003ethe DRBEF4824STANMC shows a width of 24-1\/2 in, weighs more and offers two outdoor unit options, the DRHP15B42AJ2AN or the DRHP14B42AJ2AN.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf you are looking for the lightest option to handle and your furnace allows it, this is the one. If you want a known width and more matching choices, look at the other.\u003c\/p\u003e\n\n\u003ch3\u003eCompared with the other sizes in the series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3 tons: DRBEF3624MTANMC, N-coil, 24-1\/2 in wide.\u003c\/li\u003e\n\u003cli\u003e3.5 tons: DRBEF4221HTAAMC and DRBEF4221STAAMC, A-coils.\u003c\/li\u003e\n\u003cli\u003e4 tons as A-coils: DRBEF4821HTAAMC and DRBEF4821STAAMC.\u003c\/li\u003e\n\u003cli\u003e4 tons as N-coils: DRBEF4824MTANMC in addition to the DRBEF4824STANMC.\u003c\/li\u003e\n\u003cli\u003e5 tons: DRBEF6021STAAMC as an A-coil, DRBEF6024HTANMC as an N-coil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhy cold changes the choice of system\u003c\/h3\u003e\n\u003cp\u003eHere, winter is not an average: it is a succession of icy mornings, thaws and setbacks. A heat pump whose spec sheet only talks about mild temperatures leaves you guessing what happens when the mercury plunges. A match whose heating output is published at -8 °C gives you, by contrast, a concrete reference that you can compare from one quote to the next. It is not a guarantee that your home will stay comfortable in extreme cold, but it is a solid basis for discussion, and we use it to decide with you on the threshold for switching to the furnace.\u003c\/p\u003e\n\n\u003ch3\u003eAn example home for this coil\u003c\/h3\u003e\n\u003cp\u003eThink of an expanded bungalow in Longueuil, with a gas or electric furnace in the basement, a finished ceiling that is a little low and a cooling need that grows each summer. Four tons suits this size of house when the ducts are in good shape, and the N shape avoids sacrificing space. The match certified for the cold is reassuring for winter, and the furnace is still there for the extreme moments. This is the kind of home we have in mind when we recommend this model.\u003c\/p\u003e\n\n\u003ch3\u003eLeak detector and warranty\u003c\/h3\u003e\n\u003cp\u003eA box installed at the factory on models without the L suffix contains an A2L sensor and a mitigation board. It stops the outdoor unit if there is excess refrigerant, and it suits any 24 V thermostat (CDS-228 sheet). The manufacturer offers a conditional 10-year parts warranty, with registration.\u003c\/p\u003e\n\n\u003ch3\u003eOur way of installing\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-run \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company, based in Montreal for more than fifteen years. Refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. For this system, we proceed as follows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003ecoil in the plenum, insulated transition if needed, sealed joints;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit on a base or stand, brazed piping, nitrogen test, vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003estart-up, airflow adjustment and explanations at your home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTo check before committing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil only works with an outdoor unit using the same refrigerant, installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe ratings apply to the certified match, so to the DRHP15B42AJ2AN, and not to another unit.\u003c\/li\u003e\n\u003cli\u003eThe furnace blower must provide the airflow this size requires.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert rebate\u003c\/h3\u003e\n\u003cp\u003eThe matched Durastar system appears on Hydro-Québec's list of eligible heat pumps. The amount varies according to the installation date and your situation: we verify it on the official list when we prepare the quote and put the application together with you.\u003c\/p\u003e\n\n\u003ch3\u003eAsk for your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBook a free visit: we measure the furnace, check the electrical supply and leave you a written quote for the complete Durastar system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e lets you spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Durastar","offers":[{"title":"Default Title","offer_id":68402722308388,"sku":"DRBEF4821STANMC","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_DURASTAR_DRBEF_DRBEF4821STANMC_00_4_TONNES_48000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765967","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-durastar-drbef4821stanmc-n-4-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}