{"product_id":"serpentin-devaporateur-durastar-drbef6021staamc-a-5-tonnes","title":"DURASTAR DRBEF6021STAAMC Evaporator A-Coil | 5 Tons","description":"\u003ch2\u003eDRBEF6021STAAMC: five tons in an A-coil, the large size of the DRBEF series, for big homes\u003c\/h2\u003e\n\u003cp\u003eAt the top of the range is the big coil. The \u003cstrong\u003eDRBEF6021STAAMC\u003c\/strong\u003e is a Durastar A-shaped, cased evaporator coil with a nominal size of \u003cstrong\u003e5 tons\u003c\/strong\u003e (60,000 BTU\/h) and \u003cstrong\u003eR-454B\u003c\/strong\u003e refrigerant. It is designed to install on a furnace or a blower cabinet, and to pair with the \u003cstrong\u003eDRHP14B60AJ2AN\u003c\/strong\u003e outdoor unit. In \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e as on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, the homes that call for this size are not the most numerous, but they are the ones where a wrong choice costs the most.\u003c\/p\u003e\n\n\u003ch3\u003eFive tons: what are we talking about?\u003c\/h3\u003e\n\u003cp\u003eSixty thousand BTU\/h is the largest size in the series. It is aimed at large homes, multi-storey residences, open-plan layouts with high ceilings and houses with a long glazed façade. Capacity alone is not enough: at this size, the coil needs a considerable airflow, and the furnace blower must be up to it. We check this before proposing this model, and we are the first to advise a smaller size if the ducts or the blower cannot keep up.\u003c\/p\u003e\n\n\u003ch3\u003eThe A, the two-sided shape\u003c\/h3\u003e\n\u003cp\u003eTwo sloped faces that meet at the top, like a roof: the air rises into the centre and passes through both planes. It is the classic shape for upflow furnaces. It demands height, and for a five-ton size, that is a point to examine first. If the basement ceiling is low, its N version is the DRBEF6024HTANMC, 24-1\/2 in wide.\u003c\/p\u003e\n\u003cp\u003eThe cabinet is insulated and delivered ready to install. Net weight: 76 lb, which is less than its N-coil cousin. Published positions: upflow, downflow, horizontal left or right. The metering device is a TXV. The connections: 3\/8 in (liquid), 7\/8 in (suction), and two 3\/4 in NPT condensate connections.\u003c\/p\u003e\n\n\u003ch3\u003eThe outdoor partner: the DRHP14B60AJ2AN\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer's sheet lists, for this coil, the DRHP14B60AJ2AN outdoor unit and the AHRI numbers 216686623, 216686621. The published ratings of the system are a SEER2 of 15.2 and an HSPF2 of 7.8. This system is not one of the series' two cold-climate certified matches: it is another configuration, for another size of home.\u003c\/p\u003e\n\u003cp\u003eThe coil has no efficiency rating of its own. It is the system's figures, tied to an AHRI number, that matter when comparing quotes. We verify this number in the directory before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the coil does in the house\u003c\/h3\u003e\n\u003cp\u003eIt cools the air in summer by absorbing its heat and moisture, and with a heat pump, it heats in winter by passing to the air the heat captured outdoors. The furnace keeps its blower, its filters and its ducts, and takes over below a threshold programmed with you. For a large home, that is a valuable advantage: the backup heat is already there, sized for the whole dwelling.\u003c\/p\u003e\n\n\u003ch3\u003eFive tons or four? A question of airflow\u003c\/h3\u003e\n\u003cp\u003eBetween the four-ton and five-ton sizes, the difference is not limited to capacity. The larger coil needs more heat-exchange surface, therefore more airflow, therefore a suitable blower and ducts. Here are the neighbours to consider:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDRBEF6024HTANMC: 5-ton N-coil, 24-1\/2 in wide, heavier; for a low ceiling.\u003c\/li\u003e\n\u003cli\u003eDRBEF4821HTAAMC and DRBEF4821STAAMC: 4-ton A-coils, same profile as this one.\u003c\/li\u003e\n\u003cli\u003eDRBEF4821STANMC, DRBEF4824MTANMC, DRBEF4824STANMC: 4-ton N-coils.\u003c\/li\u003e\n\u003cli\u003eDRBEF4221HTAAMC and DRBEF4221STAAMC: 3.5-ton A-coils.\u003c\/li\u003e\n\u003cli\u003eDRBEF3624MTANMC: 3-ton N-coil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe DRBEF6021STAAMC is part of, under code 6021S (A), the standard-efficiency TXV coils that Durastar lists as ENERGY STAR, with ratings published for the US market.\u003c\/p\u003e\n\n\u003ch3\u003eAn example home for five tons\u003c\/h3\u003e\n\u003cp\u003eThink of a large two-storey home on the North Shore with a full basement, a kitchen open to the living room and windows across the whole back façade. In summer, the afternoon sun heats the main floor and the upstairs stays stifling. A window unit fixes nothing, and a smaller system runs out of breath. This is the kind of home for which a five-ton size is worth discussing, provided the blower and the ducts keep up. We never start from floor area alone: we look at the windows, the insulation, the exposure and the air distribution system.\u003c\/p\u003e\n\n\u003ch3\u003eWhat we check for this size\u003c\/h3\u003e\n\u003cp\u003eThree points come up every time. First, the blower: can it move the required airflow without excessive noise? Second, the air returns: are they wide enough to feed the furnace? Third, the electrical panel: does it have the room and the capacity for the outdoor unit? If any of these points fails, we propose a correction or another size, even if it reduces the value of the sale. A large house that is poorly equipped stays uncomfortable, whatever the size of the coil.\u003c\/p\u003e\n\n\u003ch3\u003eLeak detector, thermostat, warranty\u003c\/h3\u003e\n\u003cp\u003eA single box, installed at the factory on models without the L suffix, contains an A2L sensor and a mitigation board. It pauses the outdoor unit if refrigerant builds up in excess, and it works with any 24 V thermostat (CDS-228 sheet). The manufacturer's warranty is conditional, 10 years on parts, with registration.\u003c\/p\u003e\n\n\u003ch3\u003eHow we proceed\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-run \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company based in Montreal for more than fifteen years. Refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. For a system of this size, we insist on three points: the blower, the air returns and the electrical panel.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003evisit: measuring the furnace, assessing the blower, the duct system and the panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum, insulated transition if needed, sealed joints;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit on a base or stand, brazing, nitrogen leak test, vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003estart-up, airflow adjustment and explanations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTo check before choosing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil only installs with an outdoor unit using the same refrigerant, installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe ratings apply to the certified match, with the DRHP14B60AJ2AN.\u003c\/li\u003e\n\u003cli\u003eThe furnace width must match; we verify it on site.\u003c\/li\u003e\n\u003cli\u003eThe blower must provide the airflow this size requires.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert rebate\u003c\/h3\u003e\n\u003cp\u003eThe matched Durastar system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation: we verify it on the official list when we prepare the quote and put the application together with you.\u003c\/p\u003e\n\n\u003ch3\u003eAsk for your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOn site, at no charge: we measure the furnace, check the electrical service and give you a written quote for the complete Durastar system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Durastar","offers":[{"title":"Default Title","offer_id":68402725421348,"sku":"DRBEF6021STAAMC","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_DURASTAR_DRBEF_DRBEF6021STAAMC_00_5_TONNES_60000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765968","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-durastar-drbef6021staamc-a-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}