{"product_id":"serpentin-devaporateur-durastar-drbef6024seanmc-n-5-tonnes","title":"DURASTAR DRBEF6024SEANMC Evaporator N-Coil | 5 Tons","description":"\u003ch2\u003eDRBEF6024SEANMC: a 24-1\/2 in N-coil cabinet for 5-ton systems under low ceilings\u003c\/h2\u003e\n\u003cp\u003eLarge capacities are often associated with big, bulky cabinets. The \u003cstrong\u003eDRBEF6024SEANMC\u003c\/strong\u003e takes the opposite approach: it is a 5-ton (60,000 BTU\/h) Durastar evaporator coil, N-shaped and therefore shorter than an A, with a cabinet 24-1\/2 in wide and an EEV metering device. It runs on \u003cstrong\u003eR-454B refrigerant\u003c\/strong\u003e. AirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eReading the spec sheet: three key facts\u003c\/h3\u003e\n\u003cp\u003eWhat characterizes this model fits in three lines: N shape, 24-1\/2 in width, EEV metering. Each has a consequence on the job site.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe N shape limits the height of the cabinet, useful under a beam or in a low mechanical room.\u003c\/li\u003e\n\u003cli\u003eThe 24-1\/2 in width must be compared with the furnace's. When they don't match, we build an insulated transition.\u003c\/li\u003e\n\u003cli\u003eThe EEV regulates the flow of refrigerant in the coil, as opposed to the TXV of its twin, the DRBEF6024STANMC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA large capacity doesn't rule out a compact space\u003c\/h3\u003e\n\u003cp\u003eA North Shore family in a large split-level home, where the furnace sits under a low ceiling: that is the kind of case where this model makes full sense. The A-coil of the same capacity, the DRBEF6021SEAAMC, would have required height that the basement doesn't offer. Here, the N lets the 5 tons fit in a restricted space, without breaking through a ceiling.\u003c\/p\u003e\n\u003cp\u003eThe cabinet is insulated and delivered ready to set on the furnace. It mounts in upflow, downflow or horizontal position, left or right.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the EEV does for you\u003c\/h3\u003e\n\u003cp\u003eAn electronic expansion valve, or EEV, adjusts the passage of refrigerant in the coil by means of an electrical control, rather than relying only on a mechanical part. For a homeowner, this boils down to precise control of the coil, which works in its normal operating range. We have no figure to offer on energy gain: efficiency depends on the certified system, not on the coil alone.\u003c\/p\u003e\n\n\u003ch3\u003eThe piping and connections\u003c\/h3\u003e\n\u003cp\u003eThe liquid line arrives at 3\/8 in and the suction line leaves at 7\/8 in. The condensate drain has two 3\/4 in NPT connections. At 5 tons, a pan that drains well is crucial in midsummer: we test the flow at commissioning. The net weight of the unit is 100 lb, which takes two people to handle the cabinet and lift it onto the furnace.\u003c\/p\u003e\n\n\u003ch3\u003eDRBEF6024SEANMC model spec sheet\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emanufacturer: Durastar, DRBEF range;\u003c\/li\u003e\n\u003cli\u003etype: cased N-coil;\u003c\/li\u003e\n\u003cli\u003esize: 5 tons (60,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003ewidth: 24-1\/2 in;\u003c\/li\u003e\n\u003cli\u003emetering device: EEV;\u003c\/li\u003e\n\u003cli\u003econnections: liquid 3\/8 in, suction 7\/8 in;\u003c\/li\u003e\n\u003cli\u003enet weight: 100 lb;\u003c\/li\u003e\n\u003cli\u003ewarranty: conditional 10-year parts warranty, with registration (sheet CDS-228);\u003c\/li\u003e\n\u003cli\u003esafety: factory A2L sensor and mitigation board; the outdoor unit pauses if excess refrigerant is detected; standard 24 V thermostat accepted.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eChoosing between the DRBEF6024SEANMC and the DRBEF6024STANMC\u003c\/h3\u003e\n\u003cp\u003eThese two coils look very much alike: same N shape, same 24-1\/2 in width, same 5-ton capacity, same connections, same net weight of 100 lb. The difference lies in the metering device and the published pairing.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eDRBEF6024SEANMC (this one)\u003c\/strong\u003e: EEV. The pairing is confirmed case by case in the AHRI directory.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDRBEF6024STANMC\u003c\/strong\u003e: TXV, with published pairings for the DRHP15B60AJ2AN outdoor unit, so simpler to document for an incentive application.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf the incentive file weighs heavily in your decision, this is a factor to know about. If the available height is generous, you can also consider the DRBEF6021SEAAMC, an A-coil.\u003c\/p\u003e\n\n\u003ch3\u003eWhere it sits in the series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e4 tons\u003c\/strong\u003e: DRBEF4821SEAAMC, A-coil.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e3 tons\u003c\/strong\u003e: DRBEF3621MEAAMC (A) and DRBEF3621MEANMC (N).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e2 tons\u003c\/strong\u003e: DRBEF2421HEAAMC, DRBEF2421HEANMC, DRBEF2421MEANMC and DRBEF2417SEANMC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWinter heating with a heat pump\u003c\/h3\u003e\n\u003cp\u003eWith a heat pump outside, this coil gives the home's air the heat harvested outdoors. Because the heat pump moves heat instead of making it, in mild weather it delivers two to three times more heat than the electricity it consumes; this efficiency declines with the cold, and the furnace takes over below the threshold we program with you. For a large home, that is often where the difference on the winter bill is made.\u003c\/p\u003e\n\n\u003ch3\u003eWhat we do with the existing furnace\u003c\/h3\u003e\n\u003cp\u003eWe keep the furnace, its blower and its filters. We check that the blower can deliver the system's airflow, because a 5-ton coil needs a lot. If it can't, we say so clearly and propose the options, rather than letting a new system run at half strength.\u003c\/p\u003e\n\n\u003ch3\u003eWhy Durastar\u003c\/h3\u003e\n\u003cp\u003eDurastar is the heating and air conditioning brand of Ferguson, distributed in Canada by Wolseley. Its DRBEF coils, on R-454B, are installed with Durastar heat pumps and central air conditioners on a furnace.\u003c\/p\u003e\n\n\u003ch3\u003eThe installation work\u003c\/h3\u003e\n\u003cp\u003eWe are a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company, based in Montreal for more than fifteen years. RBQ licence 5645-9605-01 covers refrigeration, ventilation and electrical work.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eVisit: available height, furnace width, electrical panel.\u003c\/li\u003e\n\u003cli\u003eCabinet on the plenum, insulated transition if needed, sealed connections.\u003c\/li\u003e\n\u003cli\u003eOutdoor unit on a base, brazed copper, nitrogen, vacuum.\u003c\/li\u003e\n\u003cli\u003eDrain and thermostat.\u003c\/li\u003e\n\u003cli\u003eCommissioning, airflow, demonstration.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eTo check before ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe electrical service must accommodate the circuit of an outdoor unit this size.\u003c\/li\u003e\n\u003cli\u003eThe 24-1\/2 in width is compared with the furnace's.\u003c\/li\u003e\n\u003cli\u003eThe blower must deliver the system's airflow.\u003c\/li\u003e\n\u003cli\u003eR-454B requires pairing the coil with an outdoor unit using the same refrigerant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe built-in leak sensor\u003c\/h3\u003e\n\u003cp\u003eR-454B belongs to the A2L category. Durastar therefore mounts a sensor and a mitigation board, grouped in one housing, on this coil at the factory. If the sensor detects excess refrigerant, the outdoor unit shuts off. There is no module to add, and a standard 24 V thermostat may be suitable. We verify the device's operation at commissioning, then explain what it does.\u003c\/p\u003e\n\n\u003ch3\u003eThe drain, water and summer\u003c\/h3\u003e\n\u003cp\u003eAt 5 tons, the volume of condensation water can be considerable in humid weather. The two 3\/4 in NPT condensate connections must lead to a well-sloped drain, and we test the flow with water before leaving. A dry mechanical room is also proof that the installation was done properly.\u003c\/p\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eEligibility depends on the matched system, not on the coil alone. We consult the official Hydro-Québec list with the installation date and tell you what applies.\u003c\/p\u003e\n\n\u003ch3\u003eEstimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Durastar system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Durastar","offers":[{"title":"Default Title","offer_id":68402722636068,"sku":"DRBEF6024SEANMC","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_DURASTAR_DRBEF_DRBEF6024SEANMC_00_5_TONNES_60000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765970","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-durastar-drbef6024seanmc-n-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}