{"product_id":"serpentin-devaporateur-elios-gchma36rcas1-3-tonnes","title":"ELIOS GCHMA36RCAS1 Evaporator Coil | 3 Tons","description":"\u003ch2\u003eGCHMA36RCAS1: the 3-ton coil for 21 in wide furnaces\u003c\/h2\u003e\n\u003cp\u003eWhen a technician opens up a furnace plenum and measures 21 in wide, he already knows which coil he is looking for. The \u003cstrong\u003eElios GCHMA36RCAS1\u003c\/strong\u003e was cut for that width: a 21 × 24 × 21 in cabinet, 3 tons (36,000 BTU\/h), \u003cstrong\u003eR-454B\u003c\/strong\u003e refrigerant. It teams up with an Elios outdoor unit to cool your home in summer and, with a heat pump, heat it in winter.\u003c\/p\u003e\n\u003cp\u003eOur crews install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eThe wide twin of the GCHMA36RBAS1\u003c\/h3\u003e\n\u003cp\u003eThis coil has a sibling with the same capacity: the GCHMA36RBAS1. Both deliver 3 tons and connect to the same outdoor units. What sets them apart is the size: the RBAS1 is 17-1\/2 in wide, while the RCAS1 measures 21 × 24 × 21 in and weighs 64.37 lb.\u003c\/p\u003e\n\u003cp\u003eIn other words, capacity does not decide between the two. The furnace does. Putting a 17-1\/2 in cabinet on a 21 in furnace forces you to build a transition; putting a 21 in cabinet on a narrow furnace poses the same challenge in reverse. Well-matched widths make for a cleaner installation and tighter connections.\u003c\/p\u003e\n\n\u003ch3\u003eWhat you are actually buying\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emodel: GCHMA36RCAS1, cased evaporator coil, GCHMA line;\u003c\/li\u003e\n\u003cli\u003enominal size: 3 tons (36,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003edimensions (W × H × D): 21 × 24 × 21 in;\u003c\/li\u003e\n\u003cli\u003enet weight: 64.37 lb;\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in (9.52 mm) for the liquid line, 3\/4 in (19 mm) for the suction line;\u003c\/li\u003e\n\u003cli\u003emanufacturer's warranty: 1-year limited on parts and 5-year limited on the compressor; 10-year option (parts and compressor) available from a third party.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTwo possible certified systems\u003c\/h3\u003e\n\u003cp\u003eThe AHRI number changes with the coil and the outdoor unit you choose. For the GCHMA36RCAS1, here are the two published pairings:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eESHMA30R2AN1\u003c\/strong\u003e, AHRI 216623475: 29,000 BTU\/h cooling, 30,000 BTU\/h heating at 47 °F, SEER2 16.0 and HSPF2 9.6;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eESHMB36R2AN1\u003c\/strong\u003e, AHRI 216623812: 36,000 BTU\/h cooling, 38,000 BTU\/h heating at 47 °F, SEER2 15.8 and HSPF2 9.4.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNote that the AHRI numbers for this model differ from those of the GCHMA36RBAS1, even though the outdoor units are the same. The certificate follows the exact combination. That is why we write the full number on the quote.\u003c\/p\u003e\n\n\u003ch3\u003eA short plenum story\u003c\/h3\u003e\n\u003cp\u003eTake a common case: a homeowner in Longueuil is replacing a twenty-year-old central air conditioner. The furnace is in good shape. It measures 21 in wide. We remove the old coil, clean the plenum, then slide the insulated cabinet of the GCHMA36RCAS1 onto the top of the furnace. No ductwork has to be redone, and no sheet metal cutting is improvised.\u003c\/p\u003e\n\u003cp\u003eThis kind of job goes faster when the coil arrives in an already insulated cabinet, and the house is without heat for a shorter time.\u003c\/p\u003e\n\n\u003ch3\u003eComparison with the other models in the series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eGCHMA36RBAS1\u003c\/strong\u003e: same size, narrower cabinet (17-1\/2 in).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eGUHMA36RCAS1\u003c\/strong\u003e: 3 tons uncased, 19-5\/8 in wide.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eGUHMA36RBAS1\u003c\/strong\u003e: 3 tons uncased, 16-1\/8 in wide.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eGCHMA48RCAS1\u003c\/strong\u003e: 4 tons, 21-5\/8 in wide, a similar dimension for a larger need.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eGCHMA60RDAS1\u003c\/strong\u003e: 5 tons, 24-1\/2 in wide.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf your furnace is close to 21 in wide, this model and the GCHMA48RCAS1 look alike in width. The first suits an average home, the second a large home. The load calculation settles it.\u003c\/p\u003e\n\n\u003ch3\u003eHow the backup heat works\u003c\/h3\u003e\n\u003cp\u003eAn \"add-on\" heat pump works alongside the furnace rather than replacing it. In mild weather, the heat pump does almost all the work. When the mercury plunges, the furnace kicks in from the threshold agreed with you. You keep your existing blower, filters and ductwork.\u003c\/p\u003e\n\u003cp\u003eThe heat pump moves heat instead of producing it: in mild weather, it delivers two to three times more heat than the electricity it uses. This efficiency falls as the cold increases, which is why the furnace relay is worthwhile.\u003c\/p\u003e\n\n\u003ch3\u003eQuestions customers often ask\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMy furnace is not exactly 21 in wide. Is that a problem?\u003c\/strong\u003e No. We measure the unit and, if needed, build an insulated transition on site. This step is part of normal work, not an exception.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I keep my old air conditioner?\u003c\/strong\u003e Generally not. The coil runs on R-454B and must be paired with the outdoor unit specified by the manufacturer. We therefore install the complete system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this coil heat?\u003c\/strong\u003e Yes, when it is paired with a heat pump: it cools in summer and heats in winter. With a central air conditioner, it provides cooling only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the furnace still useful?\u003c\/strong\u003e Yes. It keeps its blower and serves as backup heat below the threshold we program with you.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the subsidy depend on the coil?\u003c\/strong\u003e It depends on the paired system, not on the coil alone. We check Hydro-Québec's official list according to the installation date.\u003c\/p\u003e\n\n\u003ch3\u003eWhy Elios, why a cabinet\u003c\/h3\u003e\n\u003cp\u003eElios is a Canadian brand distributed by Groupe Master. Its Central-Elios line pairs variable-speed outdoor units with coils offered cased (GCHMA) or uncased (GUHMA). The GCHMA36RCAS1 belongs to the first family: it arrives in an insulated cabinet, ready to set on the furnace, which speeds up the job and protects the quality of the seal.\u003c\/p\u003e\n\n\u003ch3\u003eBefore ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil and the outdoor unit must share the same refrigerant, R-454B.\u003c\/li\u003e\n\u003cli\u003eNo efficiency rating applies to the coil alone.\u003c\/li\u003e\n\u003cli\u003eThe 21 in width must match the furnace; we check before ordering.\u003c\/li\u003e\n\u003cli\u003eThe blower must deliver the system's airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eManufacturer data on the outdoor units\u003c\/h3\u003e\n\u003cp\u003eThe ESHMA and ESHMB (Central-Elios) units cover cooling from -30 to 50 °C and heating from -30 to 24 °C. The line can reach 50 m (164 ft) for 24,000 and 30,000 BTU\/h, or 75 m (246 ft) for 36,000, 48,000 and 60,000 BTU\/h. The compressor is variable-speed, and the warranty on the outdoor units is limited to 1 year on parts and 5 years on the compressor.\u003c\/p\u003e\n\n\u003ch2\u003eThe AirGreen installation, step by step\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work falls under our RBQ licence 5645-9605-01.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring visit: furnace, blower, electrical panel;\u003c\/li\u003e\n\u003cli\u003esetting the cabinet and sealing the duct connections;\u003c\/li\u003e\n\u003cli\u003einstalling the outdoor unit, brazed piping, nitrogen leak test, evacuation;\u003c\/li\u003e\n\u003cli\u003econdensate drain and thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and demonstration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert subsidy\u003c\/h3\u003e\n\u003cp\u003eThe paired Elios system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your file. We confirm it against the official list when we prepare your quote and we prepare the application with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Elios system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"ELIOS","offers":[{"title":"Default Title","offer_id":68401006051620,"sku":"GCHMA36RCAS1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ELIOS_GCHMA_GCHMA36RCAS1_00_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795722113","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-elios-gchma36rcas1-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}