{"product_id":"serpentin-devaporateur-elios-gchma48rcas1-4-tonnes","title":"ELIOS GCHMA48RCAS1 Evaporator Coil | 4 Tons","description":"\u003ch2\u003eElios GCHMA48RCAS1: 4 tons for the big house on the South Shore or the North Shore\u003c\/h2\u003e\n\u003cp\u003eA large cottage, an expanded country house, a split-level with high ceilings: these buildings need more cooling than a standard-size coil can offer. The \u003cstrong\u003eGCHMA48RCAS1\u003c\/strong\u003e is the 4-ton cased coil in the Elios line. It delivers 48,000 BTU\/h nominal size, measures 21-5\/8 × 27-3\/4 × 21-1\/2 in, weighs 96.78 lb and runs on \u003cstrong\u003eR-454B refrigerant\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eA size reserved for large floor areas\u003c\/h3\u003e\n\u003cp\u003eIn the series, there is only one 4-ton model and one 5-ton model. The others range from 2 to 3 tons. The GCHMA48RCAS1 therefore sits above most of its neighbours, and it is aimed at homes that need a larger heat output, such as those in \u003cstrong\u003eLaval\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, in \u003cstrong\u003eLongueuil\u003c\/strong\u003e or in large \u003cstrong\u003eMontreal\u003c\/strong\u003e plexes.\u003c\/p\u003e\n\u003cp\u003eBe careful, though, not to choose a large size \"just in case\". An oversized unit short-cycles, leaves moisture in the air and wears out its components faster. We always start with a load calculation, then propose the size that suits the house, not the one that happens to be in stock.\u003c\/p\u003e\n\n\u003ch3\u003eThe cabinet: 27-3\/4 in high, so plan for it\u003c\/h3\u003e\n\u003cp\u003eAt a height of 27-3\/4 in, this is a substantial cabinet. Before going any further, we measure the space between the top of the furnace and the ceiling or the start of the ductwork. In a low basement, this check can make the difference between a simple installation and an awkward fit.\u003c\/p\u003e\n\u003cp\u003eThe weight of 96.78 lb also deserves a mention. It takes two people to lift it and centre it on the furnace cabinet without damaging the insulation. Our crews are used to this work.\u003c\/p\u003e\n\n\u003ch3\u003eThe certified pairing\u003c\/h3\u003e\n\u003cp\u003eFor this model, Elios publishes a single system:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eoutdoor unit \u003cstrong\u003eESHMA48R2AN1\u003c\/strong\u003e, AHRI number 216718862: 45,000 BTU\/h cooling, 48,000 BTU\/h heating at 47 °F, SEER2 15.2 and HSPF2 8.8.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLet's be transparent: the ratings of this system are a little lower than those of the smaller sizes in the series, which show higher SEER2 values. This is common with large capacities. If your home needs 4 tons, these ratings are those of the system you get, and the useful comparison is with another quote of the same capacity, AHRI number in hand.\u003c\/p\u003e\n\n\u003ch3\u003eWhat this coil does in an \"add-on\" heat pump\u003c\/h3\u003e\n\u003cp\u003eThe coil sits in the furnace plenum. In summer, the refrigerant evaporates in it and absorbs heat from the air; the moisture condenses and runs off to the drain. In winter, with a heat pump, the cycle reverses and the heat captured outdoors passes into the air of the house. The furnace keeps its blower and its role as backup heat for the coldest weather.\u003c\/p\u003e\n\u003cp\u003eIt can be used to turn an electric furnace into a central heat pump or to replace an old central air conditioner.\u003c\/p\u003e\n\n\u003ch3\u003eChoosing between the GCHMA48RCAS1 and its neighbours\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eGCHMA36RCAS1\u003c\/strong\u003e: 3 tons, 21 in wide. Almost the same width as the 4-ton, but for an average home.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eGCHMA60RDAS1\u003c\/strong\u003e: 5 tons, 24-1\/2 in wide, for the highest demand in the series.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eGCHMA36RBAS1\u003c\/strong\u003e and \u003cstrong\u003eGCHMA24RBAS1\u003c\/strong\u003e: 3 and 2 tons, with a width of 17-1\/2 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eGUHMA36RBAS1\u003c\/strong\u003e, \u003cstrong\u003eGUHMA36RCAS1\u003c\/strong\u003e and \u003cstrong\u003eGUHMA24RBAS1\u003c\/strong\u003e: uncased models, narrower (16-1\/8 in and 19-5\/8 in).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe GCHMA48RCAS1 is therefore the coil to consider when the load calculation goes beyond 3 tons without reaching 5 tons.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003etype: cased evaporator coil, GCHMA line;\u003c\/li\u003e\n\u003cli\u003enominal size: 4 tons (48,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003edimensions (W × H × D): 21-5\/8 × 27-3\/4 × 21-1\/2 in;\u003c\/li\u003e\n\u003cli\u003enet weight: 96.78 lb;\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in (9.52 mm) for the liquid line, 3\/4 in (19 mm) for the suction line;\u003c\/li\u003e\n\u003cli\u003e1-year limited warranty on parts and 5-year limited warranty on the compressor; optional 10-year warranty (parts and compressor) available from a third party.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAirflow: the key to large systems\u003c\/h3\u003e\n\u003cp\u003eThe bigger a system is, the more air it needs. If the furnace blower is too weak or the ducts are narrow, the coil does not give its full performance: the air circulates poorly, the coil frosts up or the house stays uneven. That is why, before any commitment, we measure the blower and the condition of the existing ductwork. In any case where we have a doubt, we say so clearly before quoting.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the manufacturer publishes for the outdoor unit\u003c\/h3\u003e\n\u003cp\u003eThe ESHMA line operates in cooling from -30 to 50 °C and in heating from -30 to 24 °C. The maximum line length is 75 m (246 ft) for the 36,000, 48,000 and 60,000 BTU\/h units. The compressor is variable-speed, and the warranty on the outdoor units is limited to 1 year on parts and 5 years on the compressor.\u003c\/p\u003e\n\n\u003ch3\u003eQuestions we are often asked\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan my old air conditioner stay?\u003c\/strong\u003e Generally not. The coil runs on R-454B and must be paired with the outdoor unit specified by the manufacturer. We install the complete system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy furnace is a different width than 21-5\/8 in.\u003c\/strong\u003e We measure it and, if needed, build an insulated transition on site, so that all of the air passes through the coil.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the furnace still useful with a heat pump?\u003c\/strong\u003e Yes. It keeps its blower and acts as backup heat below the threshold we program with you.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the coil alone qualify for a subsidy?\u003c\/strong\u003e No, it is the paired system that is assessed. We check Hydro-Québec's official list according to the installation date.\u003c\/p\u003e\n\n\u003ch3\u003eChecks before purchase\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil is paired with an R-454B outdoor unit, installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe published ratings are those of the certified system, not of the coil alone.\u003c\/li\u003e\n\u003cli\u003eThe 21-5\/8 in width must match the furnace; we check it before ordering.\u003c\/li\u003e\n\u003cli\u003eThe blower must deliver the system's airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eThe AirGreen installation in Greater Montreal\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company in Montreal for more than fifteen years, under RBQ licence 5645-9605-01 for refrigeration, ventilation and electrical work. Our job includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace and checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003esetting the cabinet with two people and sealing the duct connections;\u003c\/li\u003e\n\u003cli\u003ethe outdoor unit on a base or bracket, brazed piping, nitrogen test and evacuation;\u003c\/li\u003e\n\u003cli\u003ethe condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and an explanation of how the system works.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert subsidy\u003c\/h3\u003e\n\u003cp\u003eThe paired Elios system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We check it against the official list at the quote stage and prepare the file with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Elios system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"ELIOS","offers":[{"title":"Default Title","offer_id":68401006969124,"sku":"GCHMA48RCAS1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ELIOS_GCHMA_GCHMA48RCAS1_00_4_TONNES_48000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795722116","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-elios-gchma48rcas1-4-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}