{"product_id":"serpentin-devaporateur-elios-guhma36rbas1-3-tonnes","title":"ELIOS GUHMA36RBAS1 Evaporator Coil | 3 Tons","description":"\u003ch2\u003eGUHMA36RBAS1: 3 tons uncased, narrow at 16-1\/8 in\u003c\/h2\u003e\n\u003cp\u003eHere is a coil for those who already have a good plenum and little space: the \u003cstrong\u003eElios GUHMA36RBAS1\u003c\/strong\u003e. It delivers 3 tons (36,000 BTU\/h) in 16-1\/8 × 20-1\/8 × 22-5\/8 in, weighs 27.28 lb and runs on \u003cstrong\u003eR-454B\u003c\/strong\u003e. No cabinet is supplied, which leaves the installer free to adapt it to your furnace.\u003c\/p\u003e\n\u003cp\u003eWe install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWho is this model for?\u003c\/h3\u003e\n\u003cp\u003eThree profiles come up often:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethe homeowner whose old coil has died, but whose plenum is still sound;\u003c\/li\u003e\n\u003cli\u003ethe owner-occupant of a plex where the furnace is wedged into a corner of the mechanical room;\u003c\/li\u003e\n\u003cli\u003ethe person switching from an electric furnace to a central heat pump who wants to keep the ductwork intact.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn all three cases, the absence of a cabinet frees up space and lets you reuse the enclosure already in place.\u003c\/p\u003e\n\n\u003ch3\u003eSize questions: where does it fit?\u003c\/h3\u003e\n\u003cp\u003eIts width of 16-1\/8 in is the narrowest in the series, tied with the GUHMA24RBAS1. Its height of 20-1\/8 in gives it the 3-ton capacity without widening the footprint. The depth is 22-5\/8 in. Before our visit, note the inside width of your plenum: if it is close to this size, you have probably found your model.\u003c\/p\u003e\n\u003cp\u003eIf the furnace is wider, we build an insulated transition on site; if it is much wider, the GUHMA36RCAS1 (19-5\/8 in) or a cased model will make more sense.\u003c\/p\u003e\n\n\u003ch3\u003eThe published ratings for the system\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eESHMA30R2AN1\u003c\/strong\u003e, AHRI 216623481: 29,000 BTU\/h cooling, 30,000 BTU\/h heating at 47 °F, SEER2 16.0 and HSPF2 9.6;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eESHMB36R2AN1\u003c\/strong\u003e, AHRI 216760015: 36,000 BTU\/h cooling, 38,000 BTU\/h heating at 47 °F, SEER2 15.8 and HSPF2 9.4.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese ratings describe the system, not the coil alone. The AHRI number is what proves the exact combination of models. Before signing, ask for it from any contractor who quotes you.\u003c\/p\u003e\n\n\u003ch3\u003eWhat happens inside the coil\u003c\/h3\u003e\n\u003cp\u003eImagine hundreds of thin fins with refrigerant running through them. When the air from the house passes across them, it leaves its heat behind and then reaches the rooms cooler. The water drawn out of the air condenses and runs down to the pan, then to the drain. With a heat pump, the direction of the transfer is reversed in the cold season, and the house receives the heat captured outdoors.\u003c\/p\u003e\n\u003cp\u003eThe furnace keeps its blower, its filters and its backup role when the outdoor temperature falls below the threshold agreed with you.\u003c\/p\u003e\n\n\u003ch3\u003eThe plenum first: our checklist\u003c\/h3\u003e\n\u003cp\u003eWithout a cabinet, everything rests on the condition of the plenum. Before recommending this option, we check:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethat the sheet metal is sound, with no visible corrosion;\u003c\/li\u003e\n\u003cli\u003ethat the insulation is intact or replaceable;\u003c\/li\u003e\n\u003cli\u003ethat the condensate pan and drain will line up properly;\u003c\/li\u003e\n\u003cli\u003ethat the joints can be sealed durably.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf any of these points falls short, we offer you a cased model, such as the GCHMA36RBAS1, with the same capacity and a width of 17-1\/2 in.\u003c\/p\u003e\n\n\u003ch3\u003eComparison with the other models in the series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eGUHMA36RCAS1\u003c\/strong\u003e: also 3 tons uncased, but 19-5\/8 in wide.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eGUHMA24RBAS1\u003c\/strong\u003e: 2 tons uncased, same 16-1\/8 in width, for a smaller home.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eGCHMA36RBAS1\u003c\/strong\u003e and \u003cstrong\u003eGCHMA36RCAS1\u003c\/strong\u003e: 3 tons cased, 17-1\/2 in and 21 in wide.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eGCHMA48RCAS1\u003c\/strong\u003e and \u003cstrong\u003eGCHMA60RDAS1\u003c\/strong\u003e: 4 and 5 tons for larger homes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003etype: uncased evaporator coil, GUHMA line;\u003c\/li\u003e\n\u003cli\u003enominal size: 3 tons (36,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003edimensions (W × H × D): 16-1\/8 × 20-1\/8 × 22-5\/8 in;\u003c\/li\u003e\n\u003cli\u003enet weight: 27.28 lb;\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in (9.52 mm) for the liquid line, 3\/4 in (19 mm) for the suction line;\u003c\/li\u003e\n\u003cli\u003e1-year limited warranty on parts and 5-year limited warranty on the compressor; optional 10-year warranty (parts and compressor) available from a third party.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat the heat pump changes\u003c\/h3\u003e\n\u003cp\u003eAn electric furnace turns each kilowatt-hour into an equal amount of heat. A heat pump, on the other hand, moves heat: in mild weather, it delivers two to three times more than the electricity it uses. The efficiency drops as the cold sets in, hence the usefulness of backup heat. In summer, the same equipment replaces window air conditioners.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer data for the outdoor units\u003c\/h3\u003e\n\u003cp\u003eThe ESHMA and ESHMB lines work in cooling from -30 to 50 °C and in heating from -30 to 24 °C. The line can be up to 50 m (164 ft) for 24,000 and 30,000 BTU\/h, and up to 75 m (246 ft) for 36,000, 48,000 and 60,000 BTU\/h. The compressor is variable-speed, and the warranty on the outdoor units is limited to 1 year on parts and 5 years on the compressor.\u003c\/p\u003e\n\n\u003ch3\u003eA word about the Elios brand\u003c\/h3\u003e\n\u003cp\u003eElios is a Canadian brand distributed by Groupe Master. Its Central-Elios line pairs variable-speed outdoor units with cased (GCHMA) or uncased (GUHMA) coils. This second family suits homes where the space above the furnace is limited, like many plex mechanical rooms and bungalows in the Montreal suburbs.\u003c\/p\u003e\n\u003cp\u003eOur role is to guide you to the version that suits your furnace, instead of selling the unit we happen to have on hand.\u003c\/p\u003e\n\n\u003ch3\u003eTo check before buying\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-454B requires an outdoor unit with the same refrigerant, installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe coil has no efficiency rating of its own.\u003c\/li\u003e\n\u003cli\u003eThe 16-1\/8 in width must match the furnace; we check this before ordering.\u003c\/li\u003e\n\u003cli\u003eThe blower must deliver the system's airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I keep my current air conditioner?\u003c\/strong\u003e Generally not: the R-454B coil is paired with the outdoor unit specified by the manufacturer, and we install the complete system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this coil heat?\u003c\/strong\u003e Yes, with a heat pump. With a central air conditioner, it only cools.\u003c\/p\u003e\n\n\u003ch2\u003eAirGreen installation\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company, based in Montreal for more than fifteen years, under RBQ licence 5645-9605-01 for its refrigeration, ventilation and electrical work. The job includes measuring the furnace, checking the blower, the electrical panel and the plenum, installing the coil and sealing the connections, installing the outdoor unit with brazed piping, nitrogen test and evacuation, connecting the drain and the thermostat, then commissioning with airflow adjustment.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert subsidy\u003c\/h3\u003e\n\u003cp\u003eThe paired Elios system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We check it against the official list at the quote stage and prepare the file with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Elios system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"ELIOS","offers":[{"title":"Default Title","offer_id":68400985702692,"sku":"GUHMA36RBAS1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ELIOS_GUHMA_GUHMA36RBAS1_00_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795722139","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-elios-guhma36rbas1-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}