{"product_id":"serpentin-devaporateur-goodman-capea2418b3-a-2-tonnes","title":"GOODMAN CAPEA2418B3 Evaporator A-Coil | 2 Tons","description":"\u003ch2\u003eCAPEA2418B3: the narrow 2-ton evaporator coil for the plex and the townhouse\u003c\/h2\u003e\n\u003cp\u003eIn a plex unit or a row house, the furnace is rarely tucked into a big mechanical room. It sits in a closet between the washing machine and the water heater, and every inch counts. That is exactly where the \u003cstrong\u003eGoodman CAPEA2418B3\u003c\/strong\u003e makes sense: an evaporator A-coil that comes with its cabinet, only 17-1\/2 in wide, with a nominal size of 2 tons (24,000 BTU\/h) and running on R-32 refrigerant.\u003c\/p\u003e\n\u003cp\u003eWe install it for homeowners in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e. This page explains what this coil does, which homes it suits, how it compares with the other models in the CAPEA line, and what we check before ordering a single part.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the CAPEA2418B3 does in your system\u003c\/h3\u003e\n\u003cp\u003eThe coil is the part that exchanges heat with the air in your home. It slides into the plenum, right above the furnace or the blower cabinet. Warm air from your rooms passes through its fins, the liquid refrigerant evaporates inside and carries the heat outdoors. The water that condenses on the metal drips into the pan and leaves through the drain.\u003c\/p\u003e\n\u003cp\u003eOn its own, it does nothing: it waits for refrigerant from an outdoor unit. Paired with a central air conditioner, it cools. Paired with a heat pump, the cycle can reverse and the same piece of metal becomes the source of winter heat, through the ductwork you already have.\u003c\/p\u003e\n\n\u003ch3\u003eWhy 17-1\/2 in makes all the difference in a small space\u003c\/h3\u003e\n\u003cp\u003eWidth is the first measurement we take. A cabinet has to match the furnace it sits on. When the furnace is narrow, a wider cabinet forces a makeshift transition, and every transition adds work and more joints to seal.\u003c\/p\u003e\n\u003cp\u003eThe CAPEA2418B3 is the narrowest in the series, tied with the other 17-1\/2 in models. It measures 17-1\/2 × 18 × 21 in (width, height, depth): a modest height, useful when the basement ceiling is low or when the return plenum is tight.\u003c\/p\u003e\n\n\u003ch3\u003eWhich homes is a 2-ton size right for?\u003c\/h3\u003e\n\u003cp\u003eThink of a brick duplex in the Plateau, a triplex whose top floor has its own furnace, a small bungalow on the South Shore, a compact cottage in Laval. Modest floor areas, tight windows, a well-insulated floor: that is the territory for this size.\u003c\/p\u003e\n\u003cp\u003eThe trap is oversizing. A system that is too big reaches the set temperature in a few minutes, shuts off, then starts again. The air is cooled but not dehumidified, and you end up with a house that is cool and clammy. A room-by-room load calculation done at your home avoids this mistake. If it shows you need more than 2 tons, we will tell you plainly.\u003c\/p\u003e\n\n\u003ch3\u003eWhat happens in an \"add-on\" system\u003c\/h3\u003e\n\u003cp\u003eThe term describes a heat pump added to an existing furnace. The furnace keeps its blower, its filters and its backup heating logic. The coil is inserted into the airflow path. In mild weather, the heat pump supplies almost all of the heat. When the cold turns severe, the furnace takes over, starting from a temperature threshold that we set together.\u003c\/p\u003e\n\u003cp\u003eThe metering device on this model is an EEV, an electronic expansion valve: it meters the refrigerant sent into the tubes according to the needs of the moment, rather than according to a fixed setting.\u003c\/p\u003e\n\n\u003ch3\u003eThe published match: the GZV6SA1810A outdoor unit\u003c\/h3\u003e\n\u003cp\u003eFor this coil, the manufacturer publishes a single match: the Goodman \u003cstrong\u003eGZV6SA1810A\u003c\/strong\u003e outdoor heat pump. The complete system carries AHRI number 217589358. Its published figures are as follows: 17,000 BTU\/h in cooling, 16,800 BTU\/h in heating at 47 °F, SEER2 19.0, HSPF2 8.8.\u003c\/p\u003e\n\u003cp\u003eKeep this AHRI number handy. The coil has no efficiency rating on its own: the ratings describe the trio made up of the coil, the outdoor unit and the blower. Two quotes can therefore only be compared if their AHRI numbers are known.\u003c\/p\u003e\n\n\u003ch3\u003eCAPEA2418B3 or its neighbours: how to choose\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eVersus the CAPEA2418C3\u003c\/strong\u003e: same 2-ton size, same GZV6SA1810A outdoor unit, but the C3 is 21 in wide. Choose the B3 if the furnace is narrow, the C3 if it is wider.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eVersus the CAPEA3022B3\u003c\/strong\u003e: same 17-1\/2 in width, but 2.5 tons. The extra capacity only helps if the home's load justifies it.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eVersus the 3, 4 and 5-ton models\u003c\/strong\u003e: they are meant for much larger homes, and several are offered in 21 in or 24-1\/2 in widths.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe rule is simple: choose the width from the furnace, and the capacity from the house. The two decisions are independent, and we make them one after the other.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is published for this model\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePiping connections: 5\/16 or 3\/8 in for the liquid line, 5\/8 or 3\/4 in for the suction line.\u003c\/li\u003e\n\u003cli\u003eDrainage: 3\/4 in FNPT condensate drain, with one primary and one secondary outlet.\u003c\/li\u003e\n\u003cli\u003ePositions: upflow or downflow; the downflow position requires the DFKE-02 kit for the 4830 and 6030 models.\u003c\/li\u003e\n\u003cli\u003eSafety: an R-32 refrigerant sensor, designed to last as long as the coil, detects any possible leak.\u003c\/li\u003e\n\u003cli\u003eManufacturer's warranty: 10 years on parts, with online registration within 60 days of installation, which is not required in Quebec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eR-32 and why everything is installed together\u003c\/h3\u003e\n\u003cp\u003eThe coil is designed for R-32. It does not pair with just any old air conditioner left in the yard. In general, we install the coil and the outdoor unit on the same day, with the same refrigerant charge, which removes any compatibility doubts.\u003c\/p\u003e\n\u003cp\u003eIf your current air conditioner still works well, tell us: we will honestly assess what can be reused and what cannot. But an R-32 coil needs an outdoor unit that uses the same refrigerant, and that usually rules out reuse.\u003c\/p\u003e\n\n\u003ch3\u003eThe visit, the installation and the commissioning\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company based in Montreal for more than fifteen years, and our work is covered by our RBQ licence 5645-9605-01. Here is how a project like this unfolds:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWe measure the furnace, look at the blower and take a quick look at the electrical panel.\u003c\/li\u003e\n\u003cli\u003eThe coil is installed in the plenum; the joints between the cabinet and the ducts are sealed.\u003c\/li\u003e\n\u003cli\u003eThe outdoor unit goes on a pad or a bracket, and the piping is brazed. We then pressure-test with nitrogen and pull a vacuum.\u003c\/li\u003e\n\u003cli\u003eThe condensate drain and the thermostat are connected.\u003c\/li\u003e\n\u003cli\u003eAt commissioning, we set the airflow and walk you through how it works, thermostat in hand.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently asked questions about the CAPEA2418B3\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan it heat?\u003c\/strong\u003e Yes, as long as it is paired with a heat pump. With a central air conditioner, it only cools.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy furnace is a different width, what then?\u003c\/strong\u003e We measure it and, if needed, build an insulated transition on site.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the furnace still used?\u003c\/strong\u003e Yes. It keeps its blower and takes over when the outdoor temperature drops below the programmed threshold.\u003c\/p\u003e\n\n\u003ch3\u003eBefore ordering: three points to confirm\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe R-32 refrigerant means the coil must be paired with an outdoor unit that uses the same refrigerant, installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply to the certified match, not to a makeshift assembly.\u003c\/li\u003e\n\u003cli\u003eThe furnace blower must be able to deliver the required airflow; we check this on site.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert incentive\u003c\/h3\u003e\n\u003cp\u003eThe matched system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We check the official list at the time of the quote, then put the application together with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBook a free visit: we measure the furnace, look at the electrical entrance and give you a written quote for the complete Goodman system. To spread out the cost, \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402718802212,"sku":"CAPEA2418B3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CAPEA_CAPEA2418B3_00_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765970","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-capea2418b3-a-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}