{"product_id":"serpentin-devaporateur-goodman-capea3022c3-a-2-5-tonnes","title":"GOODMAN CAPEA3022C3 Evaporator A-Coil | 2.5 Tons","description":"\u003ch2\u003eA day with the CAPEA3022C3: from the basement to commissioning\u003c\/h2\u003e\n\u003cp\u003eRather than run through a list of features, let's follow the \u003cstrong\u003eGoodman CAPEA3022C3\u003c\/strong\u003e from the preliminary visit to the first day of operation. This cased evaporator A-coil, 21 in wide, belongs to the 2.5-ton size (30,000 BTU\/h) and uses R-32 refrigerant. It is designed for a somewhat wider furnace in a mid-sized home.\u003c\/p\u003e\n\u003cp\u003eThe homeowners in Montreal, Laval, Longueuil, the North Shore and the South Shore who call us often share the same starting point: an old central air conditioner on its last legs, or an electric furnace they would like to back up with a heat pump.\u003c\/p\u003e\n\n\u003ch3\u003eBefore the visit: what we ask you to prepare\u003c\/h3\u003e\n\u003cp\u003eClear access to the furnace, locate the electrical panel and, if possible, photograph the appliance's label. Nothing more. The rest we measure ourselves. This avoids buying a cabinet based on a remembered set of dimensions.\u003c\/p\u003e\n\n\u003ch3\u003eStep one: the tape measure\u003c\/h3\u003e\n\u003cp\u003eWe note the width of the furnace. If it matches the 21 in cabinet, installation is straightforward. If not, we build an insulated transition on site. The model's dimensions are 21 × 22 × 21 in (width, height, depth); its height of 22 in is the clearance to allow above the furnace, plenum included.\u003c\/p\u003e\n\u003cp\u003eWe also check the direction of airflow. The coil is installed in the upflow or downflow position; for the 4830 and 6030 models in downflow, the manufacturer publishes the DFKE-02 kit.\u003c\/p\u003e\n\n\u003ch3\u003eStep two: the load calculation\u003c\/h3\u003e\n\u003cp\u003eAt 2.5 tons, the CAPEA3022C3 sits between the small and large sizes. It is chosen for a cottage whose upper floor is well insulated or for a bungalow whose basement is unfinished. We count the windows, assess the insulation and analyze the duct layout. If the numbers point to another size, we change models without pushing.\u003c\/p\u003e\n\n\u003ch3\u003eStep three: choosing the outdoor unit\u003c\/h3\u003e\n\u003cp\u003eTwo certified matches are published for this coil:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGoodman \u003cstrong\u003eGZV6SA1810A\u003c\/strong\u003e, AHRI 217589357: cooling 17,000 BTU\/h, heating 16,800 BTU\/h at 47 °F, SEER2 19.0, HSPF2 8.8;\u003c\/li\u003e\n\u003cli\u003eGoodman \u003cstrong\u003eGZV7SA2410A\u003c\/strong\u003e, AHRI 217589284: cooling 23,200 BTU\/h, heating 23,200 BTU\/h at 47 °F, SEER2 19.0, HSPF2 8.6.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe coil itself has no rating. It is these two AHRI numbers that describe a complete system, and any incentive application rests on them.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation day\u003c\/h3\u003e\n\u003cp\u003eIn the morning, we protect the floor, cut power to the furnace and open the plenum. The cabinet is shimmed, sealed and insulated. The connections are 5\/16 or 3\/8 in on the liquid side and 3\/4 or 7\/8 in on the suction side; the piping is carefully brazed. The condensate drain, 3\/4 in FNPT with one primary and one secondary outlet, gets its fitting and its route to a floor drain or a pump.\u003c\/p\u003e\n\u003cp\u003eOutside, the outdoor unit takes its place on its pad or bracket. We carry out the nitrogen leak test, then pull a vacuum before opening the refrigerant. In the afternoon, the thermostat is connected.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning\u003c\/h3\u003e\n\u003cp\u003eWe start up the whole system, measure the airflow, adjust the settings and check that the condensation drains properly. The coil's expansion valve is an EEV type, meaning electronic. The R-32 leak sensor, designed to last as long as the coil, is checked as well. Finally, we take the time to explain the thermostat and the threshold at which the furnace takes over from the heat pump.\u003c\/p\u003e\n\n\u003ch3\u003eWhere this model sits in the series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCAPEA3022B3\u003c\/strong\u003e: same capacity and same matches, but a narrow 17-1\/2 in cabinet.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCAPEA2418C3\u003c\/strong\u003e: same 21 in width, 2 tons, a single outdoor unit (GZV6SA1810A).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCAPEA3626C3\u003c\/strong\u003e: same width, 3 tons, matched with the GZV7SA2410A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf you are torn between two neighbours, bring us the dimensions of the furnace and the floor area served: the answer rarely comes down to anything else.\u003c\/p\u003e\n\n\u003ch3\u003eTwo house scenarios for this size\u003c\/h3\u003e\n\u003cp\u003eFirst scenario: a cottage on the North Shore, recent windows, a well-insulated attic floor, a somewhat wide furnace inherited from an older, larger air conditioner. The 21 in cabinet fits without a transition, and the 2.5-ton size is enough to cool the upper floor without chilling the main floor too fast.\u003c\/p\u003e\n\u003cp\u003eSecond scenario: a bungalow in Longueuil with a half-finished basement. The ducts mostly serve the main level. Here, a larger system would be a bad calculation: it would shut off too soon and leave moisture in the air. In both cases, it is the on-site measurement that decides, not habit.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is better not to improvise\u003c\/h3\u003e\n\u003cp\u003eBrazing, the nitrogen test and the vacuum are not decorative steps. They are what guarantees the circuit stays sealed for the life of the system. A poorly sealed joint in the plenum can also let treated air leak into the mechanical room: we check the joints by eye and by hand before closing up.\u003c\/p\u003e\n\u003cp\u003eThe same logic applies on the electrical side: we look at the panel before promising anything, because an outdoor unit needs its own circuit.\u003c\/p\u003e\n\n\u003ch3\u003eWarranty and refrigerant\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer offers a limited 10-year warranty on parts. Online registration within 60 days of installation is provided for in its sheet, but it is not required in Quebec. Because the coil runs on R-32, it is paired with an outdoor unit that uses the same refrigerant, installed along with it. An old air conditioner is generally not suitable.\u003c\/p\u003e\n\n\u003ch3\u003eThe following winter\u003c\/h3\u003e\n\u003cp\u003eWhen the cold arrives, the heat pump takes the lead role. It moves heat from outdoors into your ducts; its efficiency drops with the temperature, and the furnace takes over below the threshold we programmed with you. For you, the gesture stays the same: turn the thermostat.\u003c\/p\u003e\n\u003cp\u003eIn summer, the same coil cools and dries the air. A single outdoor unit replaces the window air conditioners; cool air reaches every room through the same vents.\u003c\/p\u003e\n\n\u003ch3\u003eTo confirm before signing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 refrigerant on both sides of the system.\u003c\/li\u003e\n\u003cli\u003eThe quoted ratings: they apply to the certified match.\u003c\/li\u003e\n\u003cli\u003eThe width of the furnace and the capacity of its blower, which we check at your home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert incentive\u003c\/h3\u003e\n\u003cp\u003eThe Goodman system matched with this coil is on Hydro-Québec's list of eligible heat pumps. The amount varies with the installation date and your situation. We read it from the official list at the time of the quote, then put the application together with you.\u003c\/p\u003e\n\n\u003ch3\u003eOn to your estimate\u003c\/h3\u003e\n\u003cp\u003eAirGreen, a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company based in Montreal for more than fifteen years, works under RBQ licence 5645-9605-01. \u003cstrong\u003eRequest a free estimate: we come to your home, measure the furnace, check the electrical entrance and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402705826084,"sku":"CAPEA3022C3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CAPEA_CAPEA3022C3_00_2_5_TONNES_30000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765970","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-capea3022c3-a-2-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}