{"product_id":"serpentin-devaporateur-goodman-capea4830d3-a-4-tonnes","title":"GOODMAN CAPEA4830D3 Evaporator A-Coil | 4 Tons","description":"\u003ch2\u003eReplacing an old central air conditioner with a CAPEA4830D3: 4 tons, 24-1\/2 in cabinet\u003c\/h2\u003e\n\u003cp\u003eYour central air conditioner has fifteen or twenty summers behind it, it whistles a little, and you are wondering whether it is time to replace it, or even to take the opportunity to heat with a heat pump. The \u003cstrong\u003eGoodman CAPEA4830D3\u003c\/strong\u003e is one piece of that transition: a cased evaporator A-coil of 4 tons (48,000 BTU\/h), running on R-32 refrigerant, in a cabinet 24-1\/2 in wide.\u003c\/p\u003e\n\u003cp\u003eThis page follows the logic of a replacement: what you keep, what you change, what you check. It is written for owners of large homes in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eWhat you keep\u003c\/h3\u003e\n\u003cp\u003eThe furnace, first, with its blower and its filters. The duct network too, unless the inspection reveals a section to correct. The thermostat can stay or be replaced depending on its compatibility. Keeping these elements is what gives a furnace-based system its value: you do not open up walls and you do not redo the air distribution.\u003c\/p\u003e\n\n\u003ch3\u003eWhat you change\u003c\/h3\u003e\n\u003cp\u003eThe coil and the outdoor unit, together. This is the rule that comes up most often. The CAPEA4830D3 runs on R-32; the outdoor unit must use the same refrigerant. The original unit, which ran on a different fluid, cannot simply be reconnected. That is why the answer to \"can I keep my air conditioner?\" is, in general, no.\u003c\/p\u003e\n\u003cp\u003eThe old coil is removed from the plenum, the new one takes its place in its insulated cabinet, and the joints are redone from scratch.\u003c\/p\u003e\n\n\u003ch3\u003eThe cabinet width: 24-1\/2 in\u003c\/h3\u003e\n\u003cp\u003eThe D3 is the wider of the two 4-ton models. Its dimensions are 24-1\/2 × 30 × 21 in (width, height, depth). If your furnace is wide and the old coil occupied a large cabinet, this is probably the one. If needed, we build an insulated transition on site to make up a small difference.\u003c\/p\u003e\n\n\u003ch3\u003eThe two published matches\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eGZV9SA241CA\u003c\/strong\u003e, AHRI 216699892: cooling 23,400 BTU\/h, heating 22,000 BTU\/h at 47 °F, SEER2 19.2, HSPF2 9.2;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eGZV7SA3610A\u003c\/strong\u003e, AHRI 217589303: cooling 35,000 BTU\/h, heating 35,000 BTU\/h at 47 °F, SEER2 19.0, HSPF2 8.5.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAt your visit, we will lay these two options side by side with the calculated load of your home. The coil itself has no efficiency rating: it is the AHRI numbers that count when comparing quotes.\u003c\/p\u003e\n\n\u003ch3\u003eD3 versus C3, and versus the other sizes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCAPEA4830C3\u003c\/strong\u003e: same capacity, same units, 21 in wide.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCAPEA3626D3\u003c\/strong\u003e: same 24-1\/2 in width, but 3 tons.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e: same width, 5 tons, three published matches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor a replacement, the width of the old cabinet is a very good clue: measure it, or take a photo of the nameplate.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the heat pump adds to the old air conditioner\u003c\/h3\u003e\n\u003cp\u003eAn air conditioner does only one thing: cool. A heat pump matched with the same coil can also heat. In mild weather, it supplies two to three times more heat than the electricity it consumes, whereas an electric furnace turns each kilowatt-hour into an equal amount of heat. The colder it gets, the more this efficiency drops, and the furnace then takes over, at a threshold set with you.\u003c\/p\u003e\n\n\u003ch3\u003eThe signs that replacement is approaching\u003c\/h3\u003e\n\u003cp\u003eAn aging air conditioner gives clues: it runs a long time without reaching the set temperature, the summer bill climbs, traces of water appear around the furnace, or a technician has already mentioned a refrigerant leak. None of these signs calls for immediate replacement, but together they justify a quote. It is better to think about the complete system during the good season of the year than in the urgency of a heat wave.\u003c\/p\u003e\n\n\u003ch3\u003eThe coil and the condensate pan\u003c\/h3\u003e\n\u003cp\u003eIn a replacement, we also check the pan and the drain. An old rusted pan, a partly blocked drain line or a drain without enough slope are classic causes of water leaks. The new coil comes with a primary and a secondary drain: we connect both, so that the water always finds its way.\u003c\/p\u003e\n\n\u003ch3\u003eA quieter, more even system\u003c\/h3\u003e\n\u003cp\u003eOwners who replace an old system often notice the noise first: the outdoor unit is heard less and the air reaches the vents more gently. They also notice the steadiness of the temperature from room to room. It is not magic: it is the result of a certified match, an airflow set at commissioning and joints redone from scratch.\u003c\/p\u003e\n\n\u003ch3\u003eWhy 4 tons, for which home\u003c\/h3\u003e\n\u003cp\u003eThis size is for large homes with a furnace: cottages with several bedrooms, extended bungalows, residences with a high-ceilinged living room. We always validate it with the load calculation. It is tempting to replace \"one unit with an identical unit,\" but the home may have changed since the original installation: windows replaced, attic insulated, basement finished. The useful capacity is not necessarily the same any more.\u003c\/p\u003e\n\n\u003ch3\u003eThe model's technical details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEEV expansion device, electronic type.\u003c\/li\u003e\n\u003cli\u003eConnections of 3\/8 in on the liquid side, 7\/8 or 1-1\/8 in on the suction side.\u003c\/li\u003e\n\u003cli\u003e3\/4 in FNPT condensate drain, with primary and secondary outlets.\u003c\/li\u003e\n\u003cli\u003eUpflow or downflow positions; the DFKE-02 kit is needed for the 4830 and 6030 models in the downflow position.\u003c\/li\u003e\n\u003cli\u003eR-32 leak sensor, designed to last as long as the coil.\u003c\/li\u003e\n\u003cli\u003eLimited 10-year warranty on parts; online registration within 60 days of installation, not required in Quebec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow a replacement goes at AirGreen\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasuring the furnace, inspecting the blower and the electrical panel.\u003c\/li\u003e\n\u003cli\u003eRemoving the old coil, installing the new one, sealing the duct connections.\u003c\/li\u003e\n\u003cli\u003eInstalling the outdoor unit, brazing the piping, nitrogen leak test, vacuum.\u003c\/li\u003e\n\u003cli\u003eConnecting the drain and the thermostat.\u003c\/li\u003e\n\u003cli\u003eCommissioning, airflow adjustment, walkthrough for the household.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAirGreen is a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company based in Montreal for more than fifteen years, and our refrigeration, ventilation and electrical work is covered by RBQ licence 5645-9605-01.\u003c\/p\u003e\n\n\u003ch3\u003eChecklist before deciding\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe outdoor unit must be R-32, like the coil.\u003c\/li\u003e\n\u003cli\u003eThe ratings apply to the certified match, not to a free-form assembly.\u003c\/li\u003e\n\u003cli\u003eThe furnace must be the right width and have a blower that provides the system's airflow.\u003c\/li\u003e\n\u003cli\u003eThe electrical entrance must be able to supply an outdoor unit of this size.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert incentive\u003c\/h3\u003e\n\u003cp\u003eThe matched system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We check it against the official list at the time of the quote and prepare the application with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWe offer a free in-home estimate: we measure the furnace, check the electrical entrance and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402709430564,"sku":"CAPEA4830D3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CAPEA_CAPEA4830D3_00_4_TONNES_48000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765973","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-capea4830d3-a-4-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}