{"product_id":"serpentin-devaporateur-goodman-capea6030d3-a-5-tonnes","title":"GOODMAN CAPEA6030D3 Evaporator A-Coil | 5 Tons","description":"\u003ch2\u003eCAPEA6030D3: five common beliefs about a 5-ton, 24-1\/2 in coil\u003c\/h2\u003e\n\u003cp\u003eA large coil attracts beliefs. \"Bigger is safer.\" \"The number on the box is the efficiency.\" \"My old air conditioner will do fine with it.\" The \u003cstrong\u003eGoodman CAPEA6030D3\u003c\/strong\u003e is a cased evaporator A-coil of 5 tons (60,000 BTU\/h), running on R-32 refrigerant, in a cabinet 24-1\/2 in wide: the largest in the CAPEA line by both capacity and width.\u003c\/p\u003e\n\u003cp\u003eHere is what we tell the homeowners in Montreal, Laval, Longueuil, on the North Shore and on the South Shore who ask us these questions.\u003c\/p\u003e\n\n\u003ch3\u003eBelief: bigger is safer\u003c\/h3\u003e\n\u003cp\u003eFalse, and in fact the opposite. A system that is too big reaches the set point quickly, shuts off, then starts again: the air is cooled without being dried, and the house becomes clammy. The right size is the one the load calculation confirms. For a very large, heavily glazed or very open home, 5 tons can be justified; for a home that is simply large, a smaller size is sometimes enough. We tell you so even if it changes the model.\u003c\/p\u003e\n\n\u003ch3\u003eBelief: the efficiency rating is written on the coil\u003c\/h3\u003e\n\u003cp\u003eNot that either. The coil has no efficiency rating of its own. SEER2 and HSPF2 belong to the matched system, identified by an AHRI number. For this coil, the manufacturer publishes three systems:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eGZV7SA3610A\u003c\/strong\u003e, AHRI 217589305: cooling 35,000 BTU\/h, heating 35,000 BTU\/h at 47 °F, SEER2 19.0, HSPF2 8.5;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eGZV9SA361CA\u003c\/strong\u003e, AHRI 216699918: cooling 34,200 BTU\/h, heating 32,600 BTU\/h at 47 °F, SEER2 19.0, HSPF2 9.2;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eGZV9SA4810A\u003c\/strong\u003e, AHRI 217989208: cooling 46,000 BTU\/h, heating 47,000 BTU\/h at 47 °F, SEER2 18.0, HSPF2 9.0.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNote that these ratings differ from one system to the next while the coil stays the same: proof that the rating follows the outdoor unit and the whole assembly, not the part alone.\u003c\/p\u003e\n\n\u003ch3\u003eBelief: my old air conditioner will do fine with it\u003c\/h3\u003e\n\u003cp\u003eIn general, no. The coil runs on R-32 and must be matched with an outdoor unit that uses the same refrigerant, installed along with it. It is designed with an R-32 leak sensor to last as long as the coil. Mixing generations of equipment invites uncertain operation that nobody can certify. We install the complete system.\u003c\/p\u003e\n\n\u003ch3\u003eBelief: a big furnace means a big cabinet, automatically\u003c\/h3\u003e\n\u003cp\u003eThe width of the cabinet must match that of the furnace, not the capacity. The D3 measures 24-1\/2 × 30 × 21 in (width, height, depth). Its 21 in twin, the CAPEA6030C3, offers the same capacity, the same three matches and the same height of 30 in. Only the width changes. We measure the furnace, and if needed we build an insulated transition on site.\u003c\/p\u003e\n\n\u003ch3\u003eBelief: the coil replaces the furnace\u003c\/h3\u003e\n\u003cp\u003eIn an \"add-on\" system, the furnace keeps its blower, its filters and its backup role. The coil fits into the plenum and works with it. In winter, with a heat pump, the cycle reverses and the coil passes heat to the air; when the outdoor temperature drops below the threshold programmed with you, the furnace takes over. The existing ducts serve all year round.\u003c\/p\u003e\n\n\u003ch3\u003eAnd the question of noise and comfort?\u003c\/h3\u003e\n\u003cp\u003eMany people fear that a large system will be noisy. Noise depends mostly on the speed of the air in the ducts and on where the outdoor unit sits, not on the coil alone. We choose the location of the unit so that it does not face a bedroom window, and we set the airflow at commissioning. The result is judged by ear, room by room, before we leave.\u003c\/p\u003e\n\u003cp\u003eOn comfort, in summer the coil removes moisture from the air; in winter, heat arrives through the same vents as before. You do not have to learn a new way of living: the thermostat remains the only device to set for both seasons.\u003c\/p\u003e\n\n\u003ch3\u003eA South Shore home, a concrete example\u003c\/h3\u003e\n\u003cp\u003eConsider a large residence on the South Shore, whose original furnace was replaced a few years ago with a wider model. The owner wants to add air conditioning and, eventually, reduce dependence on electricity for heating. We measure the furnace, find a width of 24-1\/2 in, calculate the load and, if it justifies it, propose the CAPEA6030D3 with one of the three published units. If the load is more moderate, we propose the CAPEA4830D3 instead, of the same width. In both cases, the cabinet fits the furnace without improvisation.\u003c\/p\u003e\n\n\u003ch3\u003eWhere this model sits in the series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCAPEA6030C3\u003c\/strong\u003e: same capacity, 21 in wide.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCAPEA4830D3\u003c\/strong\u003e: same 24-1\/2 in width, 4 tons, two published matches.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCAPEA3626D3\u003c\/strong\u003e: same width, 3 tons, a single match.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe technical data, no detours\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEEV expansion device.\u003c\/li\u003e\n\u003cli\u003eConnections: 3\/8 in (liquid), 7\/8 or 1-1\/8 in (suction).\u003c\/li\u003e\n\u003cli\u003e3\/4 in FNPT condensate drain, with primary and secondary outlets.\u003c\/li\u003e\n\u003cli\u003eUpflow or downflow positions; DFKE-02 kit for the 4830 and 6030 models in downflow.\u003c\/li\u003e\n\u003cli\u003eLimited 10-year warranty on parts; online registration within 60 days of installation, not required in Quebec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe electrical entrance and the blower, two essential checks\u003c\/h3\u003e\n\u003cp\u003eA system of this size draws on the outdoor unit's power supply and on the blower's airflow. We check the panel, the circuit capacity and the blower before proposing a match. If the electrical entrance is too tight, we tell you at the visit.\u003c\/p\u003e\n\n\u003ch3\u003eWhat we do on installation day\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasuring the furnace, checking the blower and the panel.\u003c\/li\u003e\n\u003cli\u003eCoil installed in the plenum, duct connections sealed.\u003c\/li\u003e\n\u003cli\u003eOutdoor unit on a pad or bracket, piping brazed, nitrogen test, vacuum.\u003c\/li\u003e\n\u003cli\u003eDrain and thermostat connected.\u003c\/li\u003e\n\u003cli\u003eCommissioning and explanation of how it works.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAirGreen is a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company based in Montreal for more than fifteen years; our refrigeration, ventilation and electrical work is covered by RBQ licence 5645-9605-01.\u003c\/p\u003e\n\n\u003ch3\u003eTo check before buying\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 outdoor unit, installed at the same time.\u003c\/li\u003e\n\u003cli\u003ePublished ratings: valid for the certified match.\u003c\/li\u003e\n\u003cli\u003eFurnace of the right width, with a sufficient blower.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert incentive\u003c\/h3\u003e\n\u003cp\u003eThe matched system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We check it against the official list at the time of the quote and prepare the application with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOur estimate is free and done at your home: we measure the furnace, check the electrical entrance and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402711396644,"sku":"CAPEA6030D3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CAPEA_CAPEA6030D3_00_5_TONNES_60000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765974","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-capea6030d3-a-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}