{"product_id":"serpentin-devaporateur-goodman-capfa2422c3-a-2-tonnes","title":"GOODMAN CAPFA2422C3 Evaporator A-Coil | 2 Tons","description":"\u003ch2\u003eGoodman CAPFA2422C3: common myths and straight answers for a 2-ton, 21 in coil\u003c\/h2\u003e\n\u003cp\u003eWhen you are getting ready to buy a heat pump or a central air conditioner, you run into a lot of half-truths. The \u003cstrong\u003eCAPFA2422C3\u003c\/strong\u003e, a Goodman 2-ton coil with a 21 in cabinet, is a good excuse to take them apart one by one. The answers below rely on the manufacturer's data sheet and on our installation experience in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003e\"A bigger coil always cools better\"\u003c\/h3\u003e\n\u003cp\u003eFalse. Capacity is chosen according to the load of the house, not according to the size of the cabinet. A unit that is too big shuts off before it has removed the moisture from the air; the room is cool, but clammy. The 2-ton model (24,000 BTU\/h) is right when the calculation supports it, and that is all.\u003c\/p\u003e\n\n\u003ch3\u003e\"Width tells you the capacity\"\u003c\/h3\u003e\n\u003cp\u003eNo more than that. In the CAPFA series, three widths exist, 14 in, 17-1\/2 in and 21 in, and each width comes in three capacities. The C3 is the wide version: it fits large-cabinet furnaces, whatever capacity is selected. Its height is 22 in and its depth is 21 in.\u003c\/p\u003e\n\n\u003ch3\u003e\"A coil has its own efficiency rating\"\u003c\/h3\u003e\n\u003cp\u003eNo. The SEER2, EER2 and HSPF2 ratings relate to a certified system: one specific coil, one specific outdoor unit, one AHRI number. When you compare two quotes, that is the number to ask for. We confirm it before ordering.\u003c\/p\u003e\n\n\u003ch3\u003e\"I can keep my old air conditioner\"\u003c\/h3\u003e\n\u003cp\u003eAlmost never. This coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer, of the same capacity and the same refrigerant. We therefore install the complete system. No R-32 match with this coil is listed by ENERGY STAR; we consult AHRI for the unit selected.\u003c\/p\u003e\n\n\u003ch3\u003e\"It only cools\"\u003c\/h3\u003e\n\u003cp\u003ePaired with a central air conditioner, yes. But with a heat pump, the same coil is used for heating: the cycle reverses and heat from outdoors is transferred to the air in the house. The furnace stays there for the coldest days, according to a temperature threshold that we set with you.\u003c\/p\u003e\n\n\u003ch3\u003e\"My furnace is not the right width, so it's impossible\"\u003c\/h3\u003e\n\u003cp\u003eThat is not an obstacle. We measure the furnace and, if needed, build an insulated transition on site. With the C3, however, this situation is less common if your cabinet is wide.\u003c\/p\u003e\n\n\u003ch3\u003eWhere the C3 sits among its neighbours\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCAPFA2422A3: 2 tons, 14 in;\u003c\/li\u003e\n\u003cli\u003eCAPFA2422B3: 2 tons, 17-1\/2 in;\u003c\/li\u003e\n\u003cli\u003eCAPFA1818C3: 21 in as well, but 1.5 tons;\u003c\/li\u003e\n\u003cli\u003eCAPFA3022C3: 21 in as well, but 2.5 tons.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAll share R-32, the piston metering device and installation in the upflow or downflow position.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the specification sheet contains\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003etype: cased A-coil;\u003c\/li\u003e\n\u003cli\u003enominal size: 2 tons (24,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003edimensions (W × H × D): 21 × 22 × 21 in;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in liquid and 3\/4 in suction;\u003c\/li\u003e\n\u003cli\u003econdensate drain: 3\/4 in FNPT, primary and secondary;\u003c\/li\u003e\n\u003cli\u003eleak detection: R-32 sensor designed to last for the life of the coil;\u003c\/li\u003e\n\u003cli\u003ewarranty: 10-year limited parts warranty, with online registration within 60 days of installation (not required in Quebec).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow we work\u003c\/h3\u003e\n\u003cp\u003eWe are a family-owned heating and cooling company based in Montreal for more than fifteen years, and our work is covered by RBQ licence 5645-9605-01.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasuring the furnace, checking the blower and the electrical panel.\u003c\/li\u003e\n\u003cli\u003eInstalling the coil in the plenum, sealing the connections.\u003c\/li\u003e\n\u003cli\u003eInstalling the outdoor unit, brazing, nitrogen test, vacuum.\u003c\/li\u003e\n\u003cli\u003eConnecting the drain and the thermostat.\u003c\/li\u003e\n\u003cli\u003eCommissioning and airflow adjustment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eBefore you decide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure the plenum: about 21 in wide?\u003c\/li\u003e\n\u003cli\u003eCheck that the clear height above the furnace accepts a 22 in cabinet.\u003c\/li\u003e\n\u003cli\u003eAsk for the AHRI number of the complete system.\u003c\/li\u003e\n\u003cli\u003eSay whether you also want heating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\"Incentives apply to the coil\"\u003c\/h3\u003e\n\u003cp\u003eThis is a common confusion. The programs target the complete system, not an isolated part. A coil alone does not qualify for assistance: it is the coil and outdoor unit together, with their AHRI number, that is reviewed. We therefore check the official list against the installation date before giving you the quote.\u003c\/p\u003e\n\u003ch3\u003e\"Once it's installed, you never touch it again\"\u003c\/h3\u003e\n\u003cp\u003eAlmost. A well-installed coil needs little, but three habits help. Change the furnace filters regularly, because clogging reduces airflow. Look at the condensate drain from time to time: standing water near the cabinet points to a blockage. Have the system checked by a technician now and then, especially before summer.\u003c\/p\u003e\n\u003ch3\u003e\"A heat pump doesn't work in Quebec's cold\"\u003c\/h3\u003e\n\u003cp\u003eIt does lose efficiency when it gets very cold, that is true, and that is exactly why the furnace stays in place. The add-on setup shares the work: the heat pump supplies heat when temperatures are moderate, and the furnace takes over below a threshold that we set with you, based on your house. Both run on the same blower and the same ducts.\u003c\/p\u003e\n\u003ch3\u003e\"All installers do it the same way\"\u003c\/h3\u003e\n\u003cp\u003eThe steps are well known, but the execution varies. Brazing the piping under nitrogen, the pressure test, the vacuum and the airflow adjustment are steps we never skip. They cannot be seen once the cabinet is closed, but they determine the life of the system.\u003c\/p\u003e\n\u003ch3\u003eA typical visit in Greater Montreal\u003c\/h3\u003e\n\u003cp\u003eWe come to your home with a tape measure and a flashlight. We open the furnace, note the model, measure the width and depth of the plenum and record the clear height. Then we go look at the electrical panel and the spot planned for the outdoor unit: sheltered from snow sliding off the roof, clear on each side, with a stable base.\u003c\/p\u003e\n\u003cp\u003eThe visit takes little time, but it shapes everything else. Once the measurements are taken, we can confirm the coil model, the match and the AHRI number, then give you a clear written quote.\u003c\/p\u003e\n\u003ch3\u003eThe role of the piston metering device\u003c\/h3\u003e\n\u003cp\u003eThis coil uses a piston to dose the refrigerant. It is a calibrated orifice, with no moving part and no electronics. Its simplicity makes it a reliable component, but it requires that the coil and the outdoor unit be properly matched, hence the importance of the AHRI number and of a careful vacuum.\u003c\/p\u003e\n\u003ch3\u003eWhen another model would be preferable\u003c\/h3\u003e\n\u003cp\u003eIf the furnace is narrow, a slimmer model, such as the 14 in CAPFA2422A3 or the 17-1\/2 in CAPFA2422B3, avoids a large transition. If the house needs a different capacity, the series offers two others with the same 21 in width: the CAPFA1818C3 and the CAPFA3022C3. We always prefer to steer you toward the model that is simplest to install, not the biggest.\u003c\/p\u003e\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eIncentives depend on the complete system. We check Hydro-Québec's official list against the installation date and tell you what applies.\u003c\/p\u003e\n\n\u003ch3\u003eEstimate and financing\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402711429412,"sku":"CAPFA2422C3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CAPFA_CAPFA2422C3_00_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765974","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-capfa2422c3-a-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}