{"product_id":"serpentin-devaporateur-goodman-capfa3022b3-a-2-5-tonnes","title":"GOODMAN CAPFA3022B3 Evaporator A-Coil | 2.5 Tons","description":"\u003ch2\u003eGoodman CAPFA3022B3: 2.5 tons and 17-1\/2 in, compared with its eight neighbours in the series\u003c\/h2\u003e\n\u003cp\u003eChoosing an evaporator coil from a series of nine models is a bit like choosing a key from a keyring. They all look alike, but only one opens the right door. The \u003cstrong\u003eCAPFA3022B3\u003c\/strong\u003e is the one you need when the furnace has a plenum of about 17-1\/2 in and the house calls for a nominal 2.5 tons of capacity, or 30,000 BTU\/h. Here is how to place it.\u003c\/p\u003e\n\n\u003ch3\u003eThe series chart, in words\u003c\/h3\u003e\n\u003cp\u003eGoodman's CAPFA line crosses three widths with three capacities. All the models share the same R-32 refrigerant, the same piston metering device and the same 3\/8 in and 3\/4 in connections.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1.5-ton capacity: CAPFA1818A3 (14 in), CAPFA1818B3 (17-1\/2 in), CAPFA1818C3 (21 in).\u003c\/li\u003e\n\u003cli\u003e2-ton capacity: CAPFA2422A3 (14 in), CAPFA2422B3 (17-1\/2 in), CAPFA2422C3 (21 in).\u003c\/li\u003e\n\u003cli\u003e2.5-ton capacity: CAPFA3022A3 (14 in), CAPFA3022B3 (17-1\/2 in), CAPFA3022C3 (21 in).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe letter in the middle of the model number indicates the width: A for the narrowest, B for the mid-width and C for the widest. The CAPFA3022B3 is therefore the B width of the highest capacity.\u003c\/p\u003e\n\n\u003ch3\u003eTwo questions to find the right model\u003c\/h3\u003e\n\u003cp\u003eFirst question: what is the width of your plenum? Measure it, or let us do it. Second question: what capacity does your house need? A load calculation answers that, not an impression.\u003c\/p\u003e\n\u003cp\u003eOnce you have those two answers, the model follows. If the furnace is 17-1\/2 in wide and the calculation gives 2.5 tons, it is the 3022 B3. If the calculation gives 2 tons, it is the CAPFA2422B3. If the calculation gives 1.5 tons, it is the CAPFA1818B3.\u003c\/p\u003e\n\n\u003ch3\u003eThe cabinet in numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ewidth: 17-1\/2 in;\u003c\/li\u003e\n\u003cli\u003eheight: 22 in;\u003c\/li\u003e\n\u003cli\u003edepth: 21 in;\u003c\/li\u003e\n\u003cli\u003etype: cased coil, A shape;\u003c\/li\u003e\n\u003cli\u003epositions: upflow or downflow;\u003c\/li\u003e\n\u003cli\u003econdensate drain: 3\/4 in FNPT, primary and secondary.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe manufacturer also provides an R-32 leak detection sensor designed to last for the life of the coil. The limited warranty is 10 years on parts, with online registration within 60 days of installation (not required in Quebec).\u003c\/p\u003e\n\n\u003ch3\u003eA year in the life of this coil\u003c\/h3\u003e\n\u003cp\u003eJune to August: the coil cools and dries the air throughout the house, and the collected water goes down the drain. September and October: with a heat pump, the same unit gently warms the house. November to March: when the cold turns sharp, the furnace takes over from the threshold set with you. April and May: the heat pump takes the controls again.\u003c\/p\u003e\n\u003cp\u003eThis calendar is not rigid. It depends on the house and its insulation. It simply shows how the heat pump and the furnace complement each other in an add-on setup.\u003c\/p\u003e\n\n\u003ch3\u003eWhy not keep the old air conditioner?\u003c\/h3\u003e\n\u003cp\u003eBecause an R-32 coil requires an outdoor unit designed for this refrigerant and of the same capacity. The SEER2, EER2 and HSPF2 ratings do not belong to the coil but to the certified system and its AHRI number. No R-32 match with this coil is listed by ENERGY STAR, so we consult AHRI for the outdoor unit selected.\u003c\/p\u003e\n\n\u003ch3\u003eAirGreen's work, from A to Z\u003c\/h3\u003e\n\u003cp\u003eAirGreen, a family-owned heating and cooling company based in Montreal for more than fifteen years, works under RBQ licence 5645-9605-01. We install this coil in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003evisit, measurements, checking the blower and the panel;\u003c\/li\u003e\n\u003cli\u003einstalling the cabinet, insulated transition if needed, sealing the connections;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit on a pad or bracket, brazing, nitrogen test, vacuum;\u003c\/li\u003e\n\u003cli\u003edrain and thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment, explanations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eMistakes to avoid\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChoosing the capacity based on the size of the cabinet rather than on the load.\u003c\/li\u003e\n\u003cli\u003eMeasuring the outside of the furnace instead of the plenum opening.\u003c\/li\u003e\n\u003cli\u003eForgetting to check the clear height for a 22 in cabinet.\u003c\/li\u003e\n\u003cli\u003eComparing quotes without asking for the AHRI number.\u003c\/li\u003e\n\u003cli\u003eMatching an R-32 coil with another refrigerant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA visit to your home, step by step\u003c\/h3\u003e\n\u003cp\u003eWe start with the furnace: model, age, rating plate, condition of the blower. We then measure the air outlet to confirm the 17-1\/2 in width and check the 21 in depth. We look at the height available for the 22 in cabinet, then at the location of the drain and the route of the piping to the outdoor unit.\u003c\/p\u003e\n\u003cp\u003eThe outdoor unit needs space around it and a stable surface. We avoid spots where snow piles up or where defrosting could interfere with operation. Once these points are validated, we prepare the quote.\u003c\/p\u003e\n\u003ch3\u003eThe role of the piston in the series\u003c\/h3\u003e\n\u003cp\u003eThe piston is a calibrated orifice that doses the refrigerant entering the coil. It has no electronics. On every model in the line, it plays the same role. That is why you should not swap one coil for another at random: each model has its own size.\u003c\/p\u003e\n\u003ch3\u003eThe coil, one part among others\u003c\/h3\u003e\n\u003cp\u003eIn a well-designed system, nothing stands alone. The blower must move the right volume of air, the ducts must distribute it well, the outdoor unit must have the right capacity and the thermostat must control the whole. The coil is only one of these parts, but it is the one that decides how much heat and moisture is removed from the air.\u003c\/p\u003e\n\u003ch3\u003eBefore signing\u003c\/h3\u003e\n\u003cp\u003eMake sure the blower can deliver the system's airflow, that the electrical panel is ready for the outdoor unit and that the match is confirmed in writing. These are three simple points that avoid surprises.\u003c\/p\u003e\n\n\u003ch3\u003eWhy a local installer makes the difference\u003c\/h3\u003e\n\u003cp\u003eA coil can be ordered online in a few clicks, but installing it takes craft: clean brazing, pressure test, vacuum, airflow adjustment. At AirGreen, these steps are done by our own crews. If an adjustment is needed after commissioning, we are close by, on the island of Montreal, in Laval, in Longueuil and on both shores.\u003c\/p\u003e\n\u003cp\u003eWe also give you a clear explanation of how it works, which filters to maintain and which drain to watch. A system you understand is a system you maintain better.\u003c\/p\u003e\n\u003ch3\u003eWhat happens if the house changes\u003c\/h3\u003e\n\u003cp\u003eA house evolves: a room is added, the attic is insulated, the windows are replaced. Each change alters the cooling and heating load. If you are planning work, mention it at the visit. We calculate the capacity taking into account the future state of the house, not only its current state, to avoid choosing a size you will regret in a few years.\u003c\/p\u003e\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eIncentives depend on the complete system. We check Hydro-Québec's official list against the installation date, then explain what applies.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402715459876,"sku":"CAPFA3022B3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CAPFA_CAPFA3022B3_00_2_5_TONNES_30000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765973","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-capfa3022b3-a-2-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}